Showing 1537-1548 of 66,285 results

The TDB Series combines accurate digital circuitry with isolated, 10A, DPDT or SPDT contacts in an 8 or 11-pin plug-in package. The TDB Series features DIP switch selectable time delays ranging from 0.1-10,230 seconds in three ranges. The TDB Series is the product of choice for custom control panel and OEM designers. Operation (Delay-on-Break): Input voltage must be applied to the input before and during timing. Upon closure of the initiate switch, the output relay is energized. The time delay begins when the initiate switch is opened (trailing edge triggered). The output remains energized during timing. At the end of the time delay, the output de-energizes. The output will energize if the initiate switch is closed when input voltage is applied. Reset: Reclosing the initiate switch during timing resets the time delay. Loss of input voltage resets the time delay and output.
Contact for Pricing
Minimum Qty: 10
Multiplier: 10
*Contact for lower quantities*

The TDB Series combines accurate digital circuitry with isolated, 10A, DPDT or SPDT contacts in an 8 or 11-pin plug-in package. The TDB Series features DIP switch selectable time delays ranging from 0.1-10,230 seconds in three ranges. The TDB Series is the product of choice for custom control panel and OEM designers. Operation (Delay-on-Break): Input voltage must be applied to the input before and during timing. Upon closure of the initiate switch, the output relay is energized. The time delay begins when the initiate switch is opened (trailing edge triggered). The output remains energized during timing. At the end of the time delay, the output de-energizes. The output will energize if the initiate switch is closed when input voltage is applied. Reset: Reclosing the initiate switch during timing resets the time delay. Loss of input voltage resets the time delay and output.
Contact for Pricing

The KRDB Series is a compact time delay relay measuring only 2 in. (50.8 mm) square. Its microcontroller timing circuit provides excellent repeat accuracy and stability. Encapsulation protects against shock, vibration, and humidity. The KRDB Series is a cost effective approach for OEM applications that require small size, isolation, reliability, and long life. Operation (Delay-on-Break): Input voltage must be applied before and during timing. Upon closure of the initiate switch, the output relay energizes. The time delay begins when the initiate switch is opened. The output remains energized during timing. At the end of the time delay, the output de-energizes. The output will energize if the initiate switch is closed when input voltage is applied. Reset: Reclosing the initiate switch during timing resets the time delay. Loss of input voltage resets the time delay and output.
Contact for Pricing
Minimum Qty: 10
Multiplier: 10
*Contact for lower quantities*

The TDM/TDMH/TDML Series is a delay-on-make timer that combines accurate digital circuitry with isolated, DPDT relay contacts in an industry standard 8-pin plug-in package. DIP switch adjustment allows precise selection of the time delay over the full time delay range. The TDM/TDMH/TDML Series is the product of choice for custom control panel and OEM designers. Operation (Delay-on-Make): Upon application of input voltage, the time delay begins. The output is de-energized before and during the time delay. At the end of the time delay, the output relay energizes and remains energized until input voltage is removed. Reset: Removing input voltage resets the time delay and output.
Contact for Pricing
Minimum Qty: 10
Multiplier: 10
*Contact for lower quantities*

Littelfuse · Symcom
250-600
3PH VOLT Monitor/475-600V/adj.RD/2m C. The 250A is a 3-phase, auto-ranging, dual-range voltage monitor that protects 190-480VAC, 50/60Hz motors regardless of size from low and high voltage, unbalance/single-phase, and reverse-phase. The product provides a user selectable nominal voltage setpoint and the voltage monitor automatically selects between the 200V and 400V range. The 250A also features adjustable or manual restart delay. This unique microcontroller-based voltage and phase-sensing device constantly monitors the 3-phase voltages to detect harmful power line conditions. When a harmful condition is detected, the Littelfuse’s output relay is deactivated after a specified trip delay. The output relay reactivates after power line conditions return to acceptable levels. The Model 250A includes advanced single LED diagnostics. Five different light patterns distinguish between faults and normal conditions.
Contact for Pricing

The 777-HVR-P2 three-phase current and voltage monitor provides motor protection with input voltage from 340–480 V ac and full load ampere range as follows: 2–20 A (looped conductors required); 20–90 A (direct); 90–800 A (external CTs required).
Contact for Pricing

The 777-LR-P2 three-phase current and voltage monitor provides motor protection with input voltage from 200–480 V ac and motor full load ampere range of 1–9 A (direct); 10–800 A (external CTs required).
Contact for Pricing

The 777-MV-P2 three-phase current and voltage monitor provides motor protection with input voltage from 100–240 V ac and motor full load ampere range of 10–800 A (external CTs required).
Contact for Pricing

The ASQU and ASTU Series of 17.5 mm, knob adjustable, universal solid-state timers offer multiple functions, voltages, and time delay ranges. Choose one of 5 functions and 4 time delay ranges via 4 selection switches located on face of the unit. Adjustment through the time range is accomplished by an onboard knob. The ASQU Series has quick connect terminals and the ASTU Series has terminal blocks.
Contact for Pricing
Minimum Qty: 10
Multiplier: 10
*Contact for lower quantities*

460-15-100-SLD is a single-channel, seal-leak detector with input voltage ac of 110–120 nominal and sensitivity at 4.7 k–100 kΩ.
Contact for Pricing

Littelfuse · D0920 Series Arc-Detection Unit
D0920.0060
The D0920 Arc Detection Unit is a high-speed arc-detection device for electrical power-distribution systems. The D0920 supports up to three point sensors (A0220) mounted in a switchboard, and requires a 230 Vac supply. On the occurrence of an arc fault, the D0920 detects the fault and pulses the trip output in less than 1 ms. The fast trip time reduces the risk of personal injury and equipment damage. The D0920 is typically supplied from the switchboard main power. The AC voltage may fail when an arc fault develops. The D0920 uses energy stored in an internal capacitor to trip the circuit breaker. The storage capacitor is an extremely long-life electrolytic capacitor with a specified life time of more than 30 years at an ambient temperature of 50°C (121°F). The trip energy stored is sufficient for circuit breakers with a 220/250 Vdc shunt trip coil. The D0920 has one output indication relay with an isolated normally-open contact, and one output indication relay with an isolated normally-closed contact. Additional features include power and trip indication, test mode, and sensitivity adjustment.
Contact for Pricing

Littelfuse · Ground-Fault and Phase-Voltage Indicator
EL3100-00
Operates on AC ungrounded systems. The EL3100 is a self-powered ground-fault and phase voltage indication system for 3-phase systems. The EL3100 meets the National Electrical Code (NEC, Article 250.21(B)) and the Canadian Electrical Code (CEC) requirements for ground detectors for ungrounded alternating-current systems. Voltage connections are provided on the EL3100 for 208, 240, 480, and 600-V systems. Three green LED’s on the EL3100 indicate the presence of phase-to-ground voltage and one red LED indicates a ground fault. The EL3100 can operate stand-alone or with up to five remote LED indicators. A solid-state relay output provides indication of a ground fault. The output relay is closed when the 3-phase neutral voltage shifts as the result of ground leakage.
Contact for Pricing