Panel-mounted remote indication and reset for the SE-325. NEMA 4 and NEMA 13 rating. Standard 22-mm mounting.
Contact for Pricing

Littelfuse · SE 330 Series
SE-330-23-11
NGR MONITOR 48-VDC ETHERNET CE NC-K4. The SE-330 is an advanced ground-fault and neutral-grounding resistor monitoring relay. It measures neutral current, neutral-to ground voltage, and neutral-to-ground resistance. It provides continuous monitoring of the neutral-to-ground path to verify that the neutral-grounding resistor (NGR) is intact. This is of utmost importance—an open NGR renders current-sensing ground-fault protection inoperative and could result in a false belief that the system is functioning properly. The SE-330 can be used with low- and medium-voltage transformers and generators with low- or high-resistance grounding used in processing, manufacturing, chemical, pulp and paper, petroleum,and water-treatment facilities. For high-voltage applications, use the SE-330HV. For applications that require conformance to Australian standard AS/NZS 2081.3:2002, see the SE-330AU. The SE-330 New Revision provides these additional features: 100 trip records with date and time stamp. A mini-USB interface to view measured values, configure settings and check event records using SE-MON330 v3.2 or later. An on-board microSD card (included) can be used for long term data logging and firmware upgrades. Ground-fault trip level is adjustable from 2 to 100percent in 10 discrete settings, and in 1percent increments when using the MEM setting and SE-MON330 v3.2 or later. Dual Ethernet ports are optionally available with support for fiber and RJ45 interfaces. IEC 61850 protocol is optionally available. COMPUTER TO RELAY CONNECTION: Connect the SE-330 to the network using astandard Ethernet patch cable. Use of a crossover cable to connect the SE-330 directly to the computer running IP-Config is not recommended. A typical router will assign an IP address to all connected computers that are using DHCP. The SE-330 does not support the use of DHCP. If the SE-330 is being set-up for first time, it is recommended to only have one SE-330 connected to the network to prevent communication errors.
Contact for Pricing

The SE-105/SE-107 is a combination ground-wire monitor and ground-fault relay for resistance-grounded systems. It continuously monitors the integrity of the ground conductor to protect portable equipment from hazardous voltages caused by ground faults. The SE-105/SE-107 is an excellent choice for trailing cables 5 kV and under in underground mining applications. For higher voltages or long-cable applications, see the SE-134C/SE-135.
Contact for Pricing

SE-330AU-01-01 is an advanced neutral-earthing resistor monitor with a supply voltage ac of 65–265 and a supply voltage dc of 85–275. Network communications is offered via USB; DeviceNet.
Contact for Pricing

The SE-105/SE-107 is a combination ground-wire monitor and ground-fault relay for resistance-grounded systems. It continuously monitors the integrity of the ground conductor to protect portable equipment from hazardous voltages caused by ground faults. The SE-105/SE-107 is an excellent choice for trailing cables 5 kV and under in underground mining applications. For higher voltages or long-cable applications, see the SE-134C/SE-135.
Contact for Pricing

Littelfuse · SE 105 Series
SE-105EL
GF-GC MONITOR 240VAC LATCHING GC. The SE-105/SE-107 is a combination ground-wire monitor and ground-fault relay for resistance-grounded systems. It continuously monitors the integrity of the ground conductor to protect portable equipment from hazardous voltages caused by ground faults. The SE-105/SE-107 is an excellent choice for trailing cables 5 kV and under in underground mining applications. For higher voltages or long-cable applications, see the SE-134C/SE-135.
Contact for Pricing

SE-325DT is a neutral-grounding resistor monitor with a supply voltage of 120 ac-dc and a ground-fault trip level of 0.5–4.0 A.
Contact for Pricing

Littelfuse · Relay Series
T3500.0040
Frequency Deviation Relay. 100/110V. The T3500 Frequency Deviation Relay will, based on a simple AC voltage measurement, monitor the change in frequency over a time period of one second. The T3500 Pick up LED will ignite as soon as the voltage frequency has changed more than 0.5 Hz to 1.5 Hz per second, while the internal relay (and the relay indication LED) activates after the frequency deviation has existed for more than 100 milliseconds. The 100 millisecond delay can be omitted by bridging two external connection terminals. An alternative delay of 50 milliseconds can be obtained by inserting a resistor between the two terminals. The Pick Up and Relay LED will ignite simultaneously if the delay is omitted.
Contact for Pricing

SE-704-0T is an earth-leakage monitor with a supply voltage dc of 48.
Contact for Pricing

Littelfuse · Relay Series
T2800.0020
OvercurrentOrEarth Fault Relay400/450V5A. The T2800 has a broad application as an earth fault – or single phase over current detection relay, it has a wide setting range for protection, control or monitoring. The relay detects the magnitude of the current and, on exceeding the preset value, an output relay will be activated after a preset time delay. Available in many versions, varying in supply voltage, measuring currents, and functions.
Contact for Pricing

Littelfuse · Relay Series
T2500.0070
Overcur&Shrt Circ400/450V5AExt out relay. The T2500 is a high quality Over-Current and Short-Circuit relay intended for protection against thermal damage and faults caused by excessive currents. The T2500 can be used to protect generators, power transmission lines and various types of consumer supplies. The T2500 monitors two levels of current and trips the circuit breaker when one of these two levels has been exceeded continuously for a time period (defined by an adjustable delay). The T2500 will support the connection of up to three phases, but will react on the largest of these three measurements. The current measurements are done through external current transformers (CTs) – typically with a secondary current of 5A. The Over-Current function can be adjusted to trip within the range of 0.5 to 1.4 x I (input current). The delay of the Over-Current function can be set between 3 to 30 seconds. The Short-Circuit function operates within the range of 1.0 to 4.0 x I. The Short-Circuit delay can be set between 0.1 and 1 second. The T2500 will react on the highest of the three input currents. The Pick-up LED will ignite as soon as the level is exceeded, while the relay is activated only after the delay has passed.
Contact for Pricing

Littelfuse · Relay Series
T2600.0040
Dual Current Relay400/450V5A 30 sec. The T2600 determines load depending start and stop level of the diesel generator. When load increases on the running diesel generators more than e.g. 90percent adjustable, for a preset time, a start signal to call for the standby diesel generator will be provided. If the load decreases more than e.g. 45percent adjustable, for a preset time, a stop signal will be provided to dismiss one of the diesel generators. The T2600 can serve an installation with up to three diesel generators. The number of diesel generators can be extended.