Showing 61-72 of 1,100 results

The MPS Motor Protection System monitors voltage, current, and temperature to provide a comprehensive package of 22 protective functions. The MPS is a modular system with integrated protection, motor control, metering, and data-logging functions. This system is typically used to provide protection for three-phase low- and medium-voltage, medium-to high-horsepower induction motors.
Contact for Pricing

Littelfuse · M8100 Series
M8100.0170
Synchroscope. The M8100 Synchroscope provides illuminated indication of the frequency and phase deviation between voltages on two separate AC systems (e.g. a generator and a busbar). The M8100 will also indicate whether or not the two systems are live. A moving light dot indicates the frequency deviation. The magnitude of the frequency deviation is indicated by the speed and direction of the movement. Clockwise movement indicates that the frequency is too high on the incoming system. Counter clockwise movement indicates that the frequency is too low. A steady light dot at 6 o’clock position indicates zero frequency deviation and 180 degrees phase deviation. Exact synchronization. frequency and phase accordance is achieved when the light dot is steady at the 12 o’clock position (when the green LEDs ignite). The M8100 scale is made up from 38 bright red LEDs. The resolution provided by the 38 LEDs is almost as fine as a pointer synchroscope, however the LED based design is far better at withstanding environmental influence from vibration, temperature and humidity.
Contact for Pricing

SE-330-03-01 is an advanced ground-fault and neutral-grounding resistor monitor with a supply voltage ac of 65–265 and a supply voltage dc of 85–275. Network communications is offered via USB; Ethernet (Dual RJ45).
Contact for Pricing

SE-330-20-00 is an advanced ground-fault and neutral-grounding resistor monitor with a supply voltage ac of 28–52 and a supply voltage dc of 36–72. Network communications is offered via USB.
Contact for Pricing

Contact for Pricing

Littelfuse · Relay Series
PGW-0STT
Relay Accessories 0STT. Online Self-Training tutorial for PGR-6200 programming. POWR-GARD Protection Relays are supplied with free software. The software simplifies programming and allows the user to save setpoint files and reuse them for similar applications. The software gives the ability to change parameters and see the impact on the protection time current curves. It also allows another device curve to be entered to view simple coordination.
Contact for Pricing

Littelfuse · Relay Series
PGW-5330
Relay Accessories 5330. Used to receive data from the PGR-5330. It displays relay set points and measured values, and features data logging of information at a selectable interval. POWR-GARD Protection Relays are supplied with free software. The software simplifies programming and allows the user to save setpoint files and reuse them for similar applications. The software gives the ability to change parameters and see the impact on the protection time current curves. It also allows another device curve to be entered to view simple coordination.
Contact for Pricing

SE-325EST is a neutral-grounding resistor monitor with a supply voltage of 240 ac and a ground-fault trip level of 0.5–4.0 A.
Contact for Pricing

SE-325N is a neutral-grounding resistor monitor with a supply voltage of 120 ac and a ground-fault trip level of 0.5–4.0 A.
Contact for Pricing

Littelfuse · SE 330 Series
SE-330HV-22-00
NGR MONITOR HV LVPS PROFIBUS. The SE-330 is an advanced ground-fault and neutral-grounding-resistor monitoring relay. It measures neutral current, neutral-to-ground voltage, and neutral-to-ground resistance. It provides continuous monitoring of the neutral-to-ground path to verify that the neutral-grounding resistor (NGR) is intact. This is of utmost importance—an open NGR renders current-sensing ground-fault protection inoperative and could result in a false belief that the system is functioning properly. The SE-330 can be used with low- and medium-voltage transformers and generators with low- or high-resistance grounding used in processing, manufacturing, chemical, pulp and paper, petroleum, and water-treatment facilities. For high-voltage applications, use the SE-330HV. For applications that require conformance to Australian standard AS/NZS 2081.3:2002, see the SE-330AU. The SE-330 New Revision provides these additional features: 100 trip records with date and time stamp. A mini-USB interface to view measured values, configure settings and check event records using SE-MON330 v3.2 or later. An on-board microSD card (included) can be used for long term data logging and firmware upgrades. Ground-fault trip level is adjustable from 2 to 100percent in 10 discrete settings, and in 1percent increments when using the MEM setting and SE-MON330 v3.2 or later. Dual Ethernet ports are optionally available with support for fiber and RJ45 interfaces. IEC 61850 protocol is optionally available.
Contact for Pricing

The SE-330 is an advanced ground-fault and neutral-grounding resistor monitoring relay that is compliant with Rule10-302 of the 2018 Canadian Electrical Code Part I (CE Code). It measures neutral current, neutral-to-ground voltage, and neutral-to-ground resistance. It provides continuous monitoring of the neutral-to-ground path to verify that the neutral-grounding resistor (NGR) is intact and that it has not been bypassed or shorted. An open NGR renders currentsensing ground-fault protection inoperative and could result in a false belief that the system is functioning properly. A shorted NGR results in higher-than-expected ground-fault current. The SE-330 can be used with low- and medium-voltage transformers and generators with low- or high-resistance grounding used in processing, manufacturing, chemical, pulp and paper, petroleum, and water-treatment facilities. For high-voltage applications, use the SE-330HV. For applications that require conformance to Australian standards, use the SE-330AU.
Contact for Pricing

The SE-134C/SE-135 is a microprocessor-based, combination ground-wire monitor and ground-fault relay for resistance-grounded or solidly grounded systems. It continuously monitors the integrity of the ground conductor to protect portable equipment from hazardous voltages caused by ground faults. The SE-134C/SE-135 is field proven in monitoring trailing cables on large mobile equipment such as drag-lines, mining shovels, shore-to-ship power cables, dock-side cranes, stacker-reclaimers, submersible pumps, and portable conveyors.
Contact for Pricing