Current Transformer for low-level ground faults, flux conditioner is standard. (30-A primary)
Contact for Pricing

Littelfuse · PGR 6130 Series
PGR-6132-240
MOTOR RELAY, 40A BUILT-IN CTS, 240VAC. The PGR-6130 Electronic Overload Relay provides protection for small three-phase motors up to 1,000 Vac. Integrated CTs are for currents up to 90 A and external CTs can be used for currents above 90 A. The protective functions include overload, overtemperature, phase imbalance, phase loss, and phase sequence.
Contact for Pricing

Littelfuse · M8100 Series
M8100.0080
Synchrosc 110/100V W/check synchro relay. The M8100 Synchroscope provides illuminated indication of the frequency and phase deviation between voltages on two separate AC systems (e.g. a generator and a busbar). The M8100 will also indicate whether or not the two systems are live. A moving light dot indicates the frequency deviation. The magnitude of the frequency deviation is indicated by the speed and direction of the movement. Clockwise movement indicates that the frequency is too high on the incoming system. Counter clockwise movement indicates that the frequency is too low. A steady light dot at 6 o’clock position indicates zero frequency deviation and 180 degrees phase deviation. Exact synchronization. frequency and phase accordance is achieved when the light dot is steady at the 12 o’clock position (when the green LEDs ignite). The M8100 scale is made up from 38 bright red LEDs. The resolution provided by the 38 LEDs is almost as fine as a pointer synchroscope, however the LED based design is far better at withstanding environmental influence from vibration, temperature and humidity.
Contact for Pricing

Littelfuse · PMA Series
PMA-12
ENC PANEL ADAPTOR MPU-16A/FT-11 FLAT. Used when replacing GE and Westinghouse FT-11 relays.
Contact for Pricing

MPU-32-SMK is a hardware kit that allows the FPU-32 or MPU-32 to be surface mounted inside an enclosure.
Contact for Pricing

Littelfuse · PMA Series
PMA-16-RTDB
MPU/FPU PMA RTD MODULE MNT FOR PMA-16. Panel mount adapter for replacing the GE Multilin 169, 169 Plus, 269, and 369, with DB-9 cut-out. The is a mounting bracket for the optionalMPS-RTD Temperature Input Module
Contact for Pricing

Littelfuse · SE 330 Series
SE-330-22-00
NGR MONITOR 48-VDC PROFIBUS. The SE-330 is an advanced ground-fault and neutral-grounding resistor monitoring relay. It measures neutral current, neutral-to ground voltage, and neutral-to-ground resistance. It provides continuous monitoring of the neutral-to-ground path to verify that the neutral-grounding resistor (NGR) is intact. This is of utmost importance—an open NGR renders current-sensing ground-fault protection inoperative and could result in a false belief that the system is functioning properly. The SE-330 can be used with low- and medium-voltage transformers and generators with low- or high-resistance grounding used in processing, manufacturing, chemical, pulp and paper, petroleum,and water-treatment facilities. For high-voltage applications, use the SE-330HV. For applications that require conformance to Australian standard AS/NZS 2081.3:2002, see the SE-330AU. The SE-330 New Revision provides these additional features: 100 trip records with date and time stamp. A mini-USB interface to view measured values, configure settings and check event records using SE-MON330 v3.2 or later. An on-board microSD card (included) can be used for long term data logging and firmware upgrades. Ground-fault trip level is adjustable from 2 to 100percent in 10 discrete settings, and in 1percent increments when using the MEM setting and SE-MON330 v3.2 or later. Dual Ethernet ports are optionally available with support for fiber and RJ45 interfaces. IEC 61850 protocol is optionally available. COMPUTER TO RELAY CONNECTION: Connect the SE-330 to the network using astandard Ethernet patch cable. Use of a crossover cable to connect the SE-330 directly to the computer running IP-Config is not recommended. A typical router will assign an IP address to all connected computers that are using DHCP. The SE-330 does not support the use of DHCP. If the SE-330 is being set-up for first time, it is recommended to only have one SE-330 connected to the network to prevent communication errors.
Contact for Pricing

Littelfuse · Relay Series
T2200.0050
Overcurrent Relay230V1A Latching output. The T2200 has a broad application where all 3 phases or any single phase current detection will function for protection, control or monitoring. The relay detects the highest of the 3 input currents and, on exceeding the preset value, an output relay will be activated after a preset time delay. Available in many versions, varying in supply voltage, measuring currents, and functions.
Contact for Pricing

SE-330-01-00 is an advanced ground-fault and neutral-grounding resistor monitor with a supply voltage ac of 65–265 and a supply voltage dc of 85–275. Network communications is offered via USB; DeviceNet.
Contact for Pricing

SE-330HV-00-01 is an advanced ground-fault and neutral-grounding resistor monitor with a supply voltage ac of 65–265 and a supply voltage dc of 85–275. This monitor is used for high-voltage applications. Network communications is offered via USB.
Contact for Pricing

Used when replacing an Atkinson Omser II with an SE-130-Series Monitor.
Contact for Pricing

Littelfuse · SE 330 Series
SE-330HV-02-01
NGR MONITOR HV PROFIBUS NC K4. The SE-330 is an advanced ground-fault and neutral-grounding-resistor monitoring relay. It measures neutral current, neutral-to-ground voltage, and neutral-to-ground resistance. It provides continuous monitoring of the neutral-to-ground path to verify that the neutral-grounding resistor (NGR) is intact. This is of utmost importance—an open NGR renders current-sensing ground-fault protection inoperative and could result in a false belief that the system is functioning properly. The SE-330 can be used with low- and medium-voltage transformers and generators with low- or high-resistance grounding used in processing, manufacturing, chemical, pulp and paper, petroleum, and water-treatment facilities. For high-voltage applications, use the SE-330HV. For applications that require conformance to Australian standard AS/NZS 2081.3:2002, see the SE-330AU. The SE-330 New Revision provides these additional features: 100 trip records with date and time stamp. A mini-USB interface to view measured values, configure settings and check event records using SE-MON330 v3.2 or later. An on-board microSD card (included) can be used for long term data logging and firmware upgrades. Ground-fault trip level is adjustable from 2 to 100percent in 10 discrete settings, and in 1percent increments when using the MEM setting and SE-MON330 v3.2 or later. Dual Ethernet ports are optionally available with support for fiber and RJ45 interfaces. IEC 61850 protocol is optionally available.