Authorized nVent Distributor
nVent XD483616S3PTSS6 - Extreme Environments Enclosure, 48x36x16, Unpainted, Stainless Steel 316L

nVent XD483616S3PTSS6 Extreme Environments Enclosure, 48x36x16, Unpainted, Stainless Steel 316L

UPC: 783510569570


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent XD483616S3PTSS6 Extreme Environments Enclosure delivers unmatched durability and protection for mission-critical applications in the harshest industrial environments. Engineered from premium 316L stainless steel, this heavy-duty enclosure resists corrosion from salt spray, chemicals, and extreme temperatures, making it ideal for offshore platforms, chemical processing plants, and coastal facilities where standard enclosures would quickly degrade. The robust 48x36x16-inch footprint provides ample space for sensitive electrical components, control systems, or instrumentation while maintaining a compact footprint for space-constrained installations. Designed for extreme reliability, the XD483616S3PTSS6 features a padlocking handle and lift-off door with full perimeter gasketing, ensuring a secure seal against dust, water, and contaminants. The 316L stainless steel construction eliminates concerns about internal component corrosion, a critical advantage over 304SS alternatives that require zinc-plated hardware. The included silicone gasket is UL Listed and field-replaceable, allowing for quick maintenance without replacing the entire enclosure. nVent offers replacement gasket kits as a standard accessory, ensuring long-term performance with minimal downtime. This enclosure excels in industries where equipment longevity directly impacts operational safety and efficiency. In oil and gas, it protects critical control panels from explosive atmospheres and corrosive offshore conditions. Water treatment plants benefit from its resistance to chlorine and other harsh chemicals, while food processing facilities appreciate its sanitary, non-porous surface that meets stringent hygiene standards. The lift-off door design simplifies panel access during installation or servicing, while the padlockable handle provides tamper-evident security for sensitive applications. nVent, a global leader in thermal management and electrical protection solutions, brings decades of expertise to the Extreme Environments Enclosure line. The XD series is trusted by engineers and facility managers who demand proven performance in extreme conditions, supported by nVent’s rigorous testing and UL certifications. Whether specifying for a new offshore rig, a chemical processing plant, or a coastal substation, the XD483616S3PTSS6 delivers the durability, security, and compliance required for critical infrastructure. Available with optional accessories such as mounting brackets and ventilation kits, this enclosure adapts seamlessly to diverse industrial applications while maintaining the highest standards of protection and reliability.
  • Seams continuously welded and ground smooth
  • EPDM gasket - Temperature range: -50 to 120C (-58 to 248F)
  • Silicone gasket - Temperature range: -60 to 250C (-76 to 482F)
  • Single-point latching on models less than 24-inches tall
  • Three-point latching on models 24-inches or taller
  • Door easily removed by loosening set screws
  • Data pocket is high-impact thermoplastic
  • Collar studs provided for mounting optional panels
  • Exterior Hardware made of corrosion resistant 316 stainless steel
  • Bonding provision on door; grounding stud on body

Specifications

Application
Controls and Drives;Corrosive Environments
Color
Unpainted
Data Pocket
Large
Depth
406 mm
Depth
16 IN
Finish
Brushed #4
Height
1,219 mm
Height
48 in
Material
316L Stainless Steel
Material
Stainless Steel 316L
Material Quality
Stainless Steel 316
Material Quality
Stainless Steel V4A
Nema Rating
Type 4X
Product Family
Extreme Environments
Protection Rating
NEMA Type 12
Replacement Gasket
Silicone
Series
Extreme Environments Enclosure
Series
XD Extreme Environments Enclosure
Size
48X36X16
Size
48x36x16 inches
Thickness
14 ga
Thickness
51.40mm (2.024")
Type
Stainless Steel Wall Mounted Industrial Enclosures
Weight
137 lb
Width
914 mm
Width
36 in
Package Dimensions (L x W x H)
53 IN x 39 IN x 21 IN
Package Dimensions (L x W x H)
134.62 cm x 99.06 cm x 53.34 cm
Package Weight (Imperial)
137.000 L
Package Weight (Metric)
62.143 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht

EP3030

Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
External operation handle 0-1 type S3 Black IP65

14333111

External operation handle 0-1 type S3 Black IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

Frequently Asked Questions

What are the dimensions of the XD483616S3PTSS6 enclosure?

The enclosure has a height of 48 inches, a width of 36 inches, and a depth of 16 inches.

What material is the XD483616S3PTSS6 enclosure made of?

The enclosure is made of Stainless Steel 316L with a brushed #4 finish and 14ga thickness.

What safety precautions should be followed during installation?

Products must be installed and used only as indicated in nVent's instruction sheets and training materials. Improper installation can lead to product malfunction, property damage, serious injury, or death.

What industry standards does the 316LSS enclosure meet?

The 316LSS enclosure is UL and cUL Recognized for Type 12, 13, 3R, 4, 4X, and classified to IEC 60529, IP66, IP69.

What are the NEMA/EEMAC types for the 316LSS enclosure?

The 316LSS enclosure meets NEMA/EEMAC Type 12, 13, 3R, 4, 4X.

What type of gasket is included with the 316LSS model?

The 316LSS model comes with a silicone replacement gasket.

What is the temperature range for the silicone gasket?

The silicone gasket has a temperature range of -60 to 250C (-76 to 482F).

What is the weight of the XD483616S3PTSS6 enclosure?

The enclosure weighs 137lb.

How is the door secured on this enclosure?

This enclosure features three-point latching as it is 24 inches or taller, and has a padlocking handle.

Does the enclosure come with internal components?

Yes, 316LSS models have stainless steel internal components.

How to Remove and Install the Door on a XD483616S3PTSS6 WXD Enclosure

Instructions for safely removing and reinstalling the door on a XD483616S3PTSS6 WXD enclosure.

Estimated time: 15m

Tools needed:

Screwdriver, Torque wrench

Supplies needed:

Mounting screws

  1. Prepare for Door Removal

    Ensure the enclosure is de-energized and any necessary safety precautions are taken before proceeding. Open the enclosure door.

  2. Remove Door Hinges

    Loosen the two screws on the hinge side of the door. Turn each screw approximately 3 turns to disengage the hinge from the enclosure frame. Carefully remove the door.

  3. Prepare for Door Installation

    Align the door with the enclosure frame, ensuring the hinges are positioned correctly to re-engage with the frame.

  4. Install Door Hinges

    Insert the hinge pins into the corresponding holes on the enclosure frame. Tighten the two screws on the hinge side of the door to approximately 25 in-lbs (2.8 Nm). Ensure the door is securely attached and can open and close smoothly.

  5. Secure the Door

    Close the door and tighten the latch screws to approximately 50 in-lbs (5.6 Nm). Verify that the door is securely closed and latched.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.