Contact for Pricing
Overview
- Consult HOFFMAN for shielding effectiveness (dB attenuation vs. frequency)
- Separate kits must be installed on both the inlet and outlet
- Cooling fan and exhaust package must be ordered separately
- EMC upgrade kit will not work with stainless steel grille option
- Mitigates electromagnetic interference (EMI) and radio frequency interference (RFI) for reliable operation.
Specifications
Application | Controls and Drives;Power Distribution |
Color | Unpainted |
Depth | 15 mm |
Depth | 0.61 in |
Finish | Galvanized |
Fits Cooling Fan Package | TFP61/TFP62 |
Fits Exhaust Grille | TEP6 |
Height | 7.85 in |
Height | 199 mm |
Material | Galvanized Steel |
Material | Mild Steel |
Series | TFP EMC Upgrade Kit |
Size | fits 6 in. Pkg in |
Size | 7.85x8.93x0.61 |
Thickness | 20 ga |
Thickness | 51.40mm (2.024") |
Type | Fans and Filter Fans |
Type | Cooling Accessories |
Weight | 0.8 lb |
Width | 8.93 in |
Width | 227 mm |
Package Dimensions (L x W x H) | 15.25 IN x 11.5 IN x 0.75 IN |
Package Dimensions (L x W x H) | 38.735 cm x 29.21 cm x 1.905 cm |
Package Weight (Imperial) | 0.800 L |
Package Weight (Metric) | 0.363 kg |
How to Install the T6EMC Cooling Fan Package
This guide provides step-by-step instructions for installing the T6EMC cooling fan package, ensuring proper setup and safety.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors
- Disconnect power
Ensure all power supplies to the enclosure are disconnected to avoid electric shock and equipment damage.
- Mount the cooling fan package
Secure the cooling fan package to the designated area in the enclosure using the provided mounting screws. Ensure it is level and firmly attached.
- Connect the fan power cord
Carefully connect the fan power cord to the appropriate terminal connectors, ensuring that the wires are not in contact with sharp objects or hot surfaces.
- Verify connections
Use a multimeter to check the connections for continuity and ensure there are no short circuits before re-energizing the system.
- Energize the system
Reconnect the power supplies to the enclosure and ensure all internal and external electrical and mechanical clearances are checked.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.