Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Material: 1.2 mm mild steel.
- Body: Folded and seam welded. Four 8.5 mm diameter holes for wall fixing. Four M6 × 13 studs for bottom profiles / mounting plate fixation.
- Gasket: Sealing is ensured by an injected one piece polyurethane gasket.
- Earthing: M8x18 mm earthing studs in body and cover, M8 nuts, earthing washers and earthing labels.
- Protection: IP 66, TYPE 4, 12, IK 08.
- Finish: RAL 7035, structured powder coating.
- Delivery: Body, cover, cover screws, fixing screws, cover plugs, and earthing facilities.
Specifications
Application | Controls and Drives;Factory Automation and Process Control |
Application | Factory Automation and Process Control; Controls and Drives |
Body Thickness | 1.2 mm |
Body Thickness | 18 ga |
Body Thickness | 16 ga |
Cable Entry | No |
Color | Gray |
Color | Grey |
Color | Light Gray |
Color | Light Gray;RAL 7035 Light Gray |
Color Code | RAL 7035 |
Construction | Body: 18 gauge Door: 18 gauge |
Cubic Capacity | 220 in3 |
Depth | 13 IN |
Depth | 3.15 in |
Depth | 80 |
Door Thickness | 14 ga |
Door Thickness | 18 ga |
Door Thickness | 1.2 mm |
Finish | Powder Coated |
Height | 44 IN |
Height | 150 |
Height | 5.91 in |
Insulation | No |
IP Rating | IP66 |
Material | Mild Steel |
Mounting | Wall Mounted |
Mounting Type | Pre-drilled mounting holes |
NEMA Rating | NEMA Type 4 NEMA Type 12 NEMA Type 13 |
NEMA Rating | 4 |
Number Of Outlet | 1 |
Protection Rating | NEMA Type 4 |
Series | STB |
Size | 150x300x80mm |
Size | 5.91 x 11.81 x 3.15 inch |
Type | Mild Steel Terminal and Junction Boxes |
Type | Mild Steel Industrial Terminal and Junction Boxes |
Weight | 4.32 lb |
Weight | 32 lbs./100ft |
Width | 300 |
Width | 11.81 in |
Width | 23 IN |
Package Dimensions (L x W x H) | 12.19 IN x 6.28 IN x 3.77 IN |
Package Dimensions (L x W x H) | 30.9626 cm x 15.9512 cm x 9.5758 cm |
Package Weight (Imperial) | 4.320 L |
Package Weight (Metric) | 1.960 kg |
Frequently Asked Questions
What is the protection degree of the STB terminal box?
The STB terminal box has an IP 66 protection degree, and is also rated TYPE 4, 12, and IK 08.
What material is the STB terminal box made of?
The terminal box is constructed from 1.2 mm mild steel and has a structured powder coating finish.
What are the dimensions of the STB153008 terminal box?
The STB153008 terminal box has dimensions of 11.81 inches in width, 5.91 inches in height, and 3.15 inches in depth.
What industry standards does the STB terminal box comply with?
The STB terminal box is UL 508A Listed (Type 4, 12, 13), cUL Listed (Type 4, 12, 13), NEMA/EEMAC Type 4, 12, 13, and IEC 62208 IP66.
What is included with the STB terminal box upon delivery?
Delivery includes the body, cover, cover screws, fixing screws, cover plugs, and earthing facilities.
How is sealing ensured in the STB terminal box?
Sealing is achieved through an injected one-piece polyurethane gasket.
What is the color and finish of the STB terminal box?
The terminal box is light gray with a RAL 7035 structured powder coating finish.
What is the weight of the STB153008 terminal box?
The STB153008 terminal box weighs 4.32lb.
Are there mounting panels included with the terminal box?
No, the panel is sold separately.
What are the earthing stud sizes in the STB terminal box?
There are M8x18 mm earthing studs located in both the body and the cover.
How to Install the STB153008 Controller
This guide provides step-by-step instructions for installing and configuring the STB153008 Controller, ensuring proper wiring and initial setup.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Wire connectors, Floor plate (if applicable)
- Prepare the installation area
Ensure the installation surface is clean and free of debris. If mounting on a combustible surface, install a floor plate of at least 1.43 mm galvanized or 1.6 mm uncoated steel, extending at least 150 mm beyond the equipment on all sides.
- Mount the controller
Secure the STB153008 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.
- Connect the wiring
Use wire connectors to connect the power supply and input/output terminals according to the wiring diagram provided in the documentation. Verify all connections are secure.
- Power on the controller
Turn on the power supply to the controller. Use a multimeter to verify that the voltage levels are within the specified range.
- Configure the controller settings
Access the configuration interface of the STB153008 and input the necessary parameters as per your application requirements. Save the settings.
- Calibrate the controller
Follow the calibration procedure outlined in the documentation to ensure accurate operation. Test the controller to confirm it is functioning correctly.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.