Contact for Pricing
Overview
- These side panels will ensure that the ingress protection is maintained, which means that the electrical components will operate without any disturbances and protect personnel from injuries.
- Feature: a set of two panels to close the sides of single or bayed combinable floor standing enclosures
- Advantage: provides ingress protection for enclosure configurations
- Benefit: ensures that the installed electrical components are safe
- Light gray powder coating for enhanced corrosion resistance
Specifications
Application | Controls and Drives; Factory Automation and Process Control |
Color | Light Gray |
Color Code | RAL 7035 |
Depth | 562 mm |
Depth | 22.13 in |
Finish | Powder Coated |
Height | 1,964 mm |
Height | 77.32 in |
Material | Mild Steel |
Mounting Type | Screw Mounting |
NEMA Rating | Type 3R |
Series | SPM-3R |
Size | 1964x19x562mm |
Thickness | 1.5 mm |
Thickness | 16 ga |
Type | Industrial Panels and Panel Accessories |
Weight | 27.1 kg |
Weight | 59.75 lb |
Width | 0.75 in |
Width | 19 mm |
Works With | NEMA |

BX4
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
LH38
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
LN43DA
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
LT20D-NEW
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, GreyHow to Assemble the SPM-3R Enclosure
This guide provides step-by-step instructions for the mechanical assembly of the SPM-3R floor-standing enclosure, including mounting the lift handle, top panel, back panel, and bottom plates.
Estimated time: 1h 30m
Tools needed:
T30 driver, SW10 wrench, T25 driver, Torque wrench
Supplies needed:
M5x10 screws, M5 nuts, M6x12 screws, St. 5.5x10 screws, M8x16 screws, BG01 sealing components (optional)
- Mount the Lift Handle
Position the metal guider (A) on the enclosure door. Place the lift handle (1) onto the metal guider. Secure the lift handle to the metal guider using four M5x10 screws (B) and two M5 nuts (C). Use a T30 driver and SW10 wrench to tighten the screws to a torque of 4-5.5 Nm.
- Install the Top Panel
Carefully place the top panel onto the enclosure frame. Secure the top panel using the specified M5x10 screws (A) and M6x12 screws (B). Use T25 and T30 drivers to tighten all screws to a torque of 4-5 Nm.
- Install the Back Panel
Position the back panel onto the rear of the enclosure. Secure the back panel using the St. 5.5x10 screws (A) and M6x12 screws (B). Tighten these screws to a torque of 4.5-5 Nm using a T25 driver. Then, install and tighten the M6x12 screws (C) to a torque of 10-15 Nm.
- Mount the Bottom Plates
Position the four bottom plates (1, 2, 3, 4) onto the base of the enclosure. Secure each bottom plate using the M8x16 screws (A, B, C, D, E, F, G) as indicated in the diagram. Use a T30 driver to tighten all M8x16 screws to a torque of 10-15 Nm.
- Seal Bottom Plates for IP55
If an IP55 rating is required, install the BG01 sealing components (ordered separately) into the bottom plates. Ensure each sealing component clicks firmly into place to create a watertight seal.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.