nVent SFCP106 - Partial Height Swing Frames, SFCP, 197x496x60mm, Zinc Plated, Mild Steel, 10U

nVent SFCP106 Partial Height Swing Frames, SFCP, 197x496x60mm, Zinc Plated, Mild Steel, 10U

UPC: 783510527914


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent SFCP106 Partial Height Swing Frame (SKU: SFCP106) is a robust 19-inch rack-mount accessory designed to enhance accessibility and organization within enclosures. Constructed from 2mm thick zinc-plated mild steel, this frame offers superior corrosion resistance and facilitates direct earthing for mounted components, ensuring electrical safety. Its rigid S-profile design provides a stable mounting platform with a standard 19-inch hole pattern on both the front and back, accommodating a variety of 19-inch equipment. The SFCP106 offers 10U of additional mounting space, making it ideal for expanding capacity in existing racks or enclosures. Engineered for versatility, it supports left or right-hand opening with a standard swing angle of 125°-155°, significantly improving access to rear equipment and cabling. This partial height swing frame is compatible with nVent wall-mounted, combinable, compact steel, and floor-standing enclosures. For mounting in wall-mounted or floor-standing combinable enclosures, the SFBP transversal support is required. It features a double-bit 3mm lock for secure closure. The SFCP106 is manufactured in the US.
  • Description: Partial height swing frame for 19”-components allowing left or right hand opening. Can be used in wall mounted, steel enclosures, and floor standing, combinable and compact, steel enclosures. Rigid S-shaped frame profile equipped with 19” hol
  • Lock: 1 double-bit 3 mm lock.
  • Material: 2 mm zinc plated steel.
  • Pack quantity: 1 swing frame with hinges.
  • Mounting requirements: Mounting in wall mounted, steel enclosures requires the SFBP transversal support in combination with the AVB. Mounting in floor standing steel combinable enclosures requires the SFBP transversal support. Adjustable in depth in combi
  • Lock: one double-bit, 3mm lock
  • Mounting requirements: mounting in wall mounted, steel enclosures requires the SFBP transversal support in combination with the AVB; mounting in floor standing steel combinable enclosures requires the SFBP transversal support; adjustable in depth in combi

Specifications

Application
Controls and Drives;Factory Automation and Process Control
Application
Factory Automation and Process Control; Controls and Drives
Color
Unpainted
Consist of
Mounting Components and Instruction Manual;Partial Height Swing Frames
Consist Of
Partial Height Swing Frames; Mounting Components and Instruction Manual
Construction
14 gauge
Depth
2.36 in
Depth
60 mm
Enclosure Material
Mild Steel
Finish
Zinc Plated
Height
7.74 in
Height
23.62 in
Height
600 mm
Height
505 mm
Height
199.6 in
Load Rating
300
Load Rating
500 N
Material
Zinc-plated mild steel
Material
Mild Steel
Mounting Type
Wall-mounted, floor-standing, combinable, compact steel enclosures
Mounting Type
19-inch rack-mount
Package Quantity
1
Rack Height
10 U
Series
SFCP
Size
7.74 x 19.53 x 2.36 inch
Size
197x496x60mm
Thickness
2 mm
Thickness
14 ga
Thickness
51.40mm (2.024")
Type
IEC Enclosure Accessories
Type
Mounting
Weight
32 lbs./100ft
Weight
2.9 kg
Weight
6.4 lb
Width
492 mm
Width
496 mm
Width
19.53 in
Works With
IEC
Package Weight (Imperial)
6.400 L
Package Weight (Metric)
2.903 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco

36297702

Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

Frequently Asked Questions

What is the catalog number for this partial height swing frame?

The catalog number for this partial height swing frame is SFCP106.

What are the dimensions of the SFCP106 swing frame?

The SFCP106 swing frame has dimensions of 197x496x60mm.

What material is the SFCP106 swing frame made of?

The SFCP106 swing frame is made of 2 mm zinc plated steel.

What is the load rating for the SFCP106 swing frame?

The load rating for the SFCP106 swing frame is 500N.

How many rack units does the SFCP106 support?

The SFCP106 swing frame supports 10U of rack height.

What type of lock is included with the SFCP106?

The SFCP106 includes a double-bit 3 mm lock.

What is the standard opening angle for the swing frame?

The standard opening angle for the swing frame is 125°-155°.

How is the SFCP106 swing frame mounted in wall-mounted enclosures?

Mounting in wall-mounted enclosures requires the SFBP transversal support in combination with the AVB.

How is the SFCP106 swing frame mounted in floor standing enclosures?

Mounting in floor standing steel combinable enclosures requires the SFBP transversal support.

Can the depth of the SFCP106 swing frame be adjusted?

Yes, the depth can be adjusted in combination with CLPK profiles.

How to Install the SFCP106 Controller

This guide provides step-by-step instructions for mounting, wiring, and configuring the SFCP106 Controller on a DIN rail.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the SFCP106 Controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the wiring

    Use terminal connectors to connect the power and signal wires to the appropriate terminals on the SFCP106 Controller. Verify that all connections are secure.

  3. Configure the controller

    Power on the SFCP106 Controller and use the configuration software to set the desired parameters. Follow the on-screen instructions to complete the setup.

  4. Calibrate the controller

    Perform a calibration of the SFCP106 Controller by following the calibration procedure in the software. Ensure all settings are saved before exiting.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.