Contact for Pricing
Overview
- Coupling can rotate 300 degrees with stop
- Gasket, set screws, and mounting hardware are included
- Assembled Syspend 180 HMI Arm System has a max weight load of 180 lb. (81.6 kg)
- Die-cast aluminum construction resists corrosion
- Compatible with Syspend suspension systems and wall flanges
Specifications
Application | Controls and Drives |
Color | Jet Black |
Color Code | RAL 9005 |
Depth | 4.93 |
Depth | 125 |
Depth | 125 mm |
Finish | Powder Coated |
Height | 174 mm |
Height | 6.86 |
Height | 174 |
Material | Aluminum |
Modification Services | Yes |
Product Family | Syspend 180-Max |
Protection Rating | IP65 |
Type | Syspend 180-Max |
Weight | 3.8 lb |
Weight | 1.59 kg |
Width | 5.24 |
Width | 133 |
Width | 133 mm |
Package Dimensions (L x W x H) | 7.7 IN x 5.6 IN x 5.4 IN |
Package Dimensions (L x W x H) | 19.558 cm x 14.224 cm x 13.716 cm |
Package Weight (Imperial) | 3.800 L |
Package Weight (Metric) | 1.724 kg |
How to Install the SYSPEND 180-MAX Suspension System
This guide provides step-by-step instructions for installing and configuring the SYSPEND 180-MAX suspension system, ensuring proper mounting and adjustment.
Estimated time: 1h
Tools needed:
Screwdriver, Multimeter, Spirit level
Supplies needed:
Mounting screws, Lock washers, Seals
- Prepare the mounting surface
Ensure the mounting surface is smooth and flat to avoid load and adjustment issues.
- Mount the suspension system
Secure the suspension system to the wall or machine using the appropriate mounting screws. Use at least four bolting points for stability.
- Attach the coupling components
Fit the screws through the horizontal section into the coupling and tighten them to a torque of 6 Nm.
- Adjust the vertical and horizontal tubes
Loosen the screws on the vertical and horizontal tubes, adjust to the desired position, and then tighten the screws to a torque of 10-12 Nm.
- Verify the alignment
Use a spirit level to check that the tubes are aligned correctly. Make adjustments if necessary.
- Perform electrical connections
Ensure all electrical connections are made by a qualified electrician, following safety protocols to avoid damage to seals.
- Calibrate the system
Adjust the clamping lever to set the desired resistance and ensure the system operates smoothly.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.