Contact for Pricing
Minimum Qty: 4
Multiplier: 4
*Contact for lower quantities*
Overview
- 6.00" x 20.00" x 120.00" straight section for high-density cable routing
- Open-mesh design promotes airflow and reduces heat buildup
- Light gray powder-coated steel for corrosion resistance and visibility
- Modular system compatible with bends, tees, and risers
- Pre-punched holes for quick alignment and secure installation
Specifications
Application | Networking, Storage and Data Center |
Cable Quantity, Cat 6 @75% Fill | 1,571 |
Color | Unpainted |
Color | Light Gray |
Color | Lt Gray |
Fill Rate, Cat 6 diam. 0.19 in | 1,571 |
Fill Rate, Cat 6A diam. 0.23 in | 1,437 |
Load | 127 lb/ft |
Load Per 6 ft Span | 127 lb/ft |
Material | Steel |
Modification Services | No |
Mounting Type | Wire Mesh Cable Tray System |
Mounting Type | Ceiling, Wall, Under Raised Floors |
Nominal Width | 20 in |
Product Family | QuickTray Pro |
Series | Quick Tray Pro |
Size | 6.00x20.00x120.00 |
Size | 6.00x20.00x120.00 inches |
Splice Quantity | 7 |
Splice Quantity, Per Joint | 7 |
Thickness | 0.2 in |
Type | Cable Pathway |
Weight | 35.75 lb |
Weight Per Section | 35 lb |
Package Dimensions (L x W x H) | 120 IN x 22 IN x 13 IN |
Package Dimensions (L x W x H) | 304.8 cm x 55.88 cm x 33.02 cm |
Package Weight (Imperial) | 35.750 L |
Package Weight (Metric) | 16.216 kg |
How to Modify and Connect QUICK TRAY PRO Cable Tray Sections
This guide provides instructions for cutting, bending, and joining QUICK TRAY PRO cable tray sections to create custom installations for cable routing.
Estimated time: 1h 30m
Tools needed:
Hoffman side action bolt cutter (QTPBC)
Supplies needed:
QUICK TRAY PRO Cable Tray sections (e.g., QTP6X20), Splice Kits (QTPBNWK or QTPBNWKBLK), Splice Washers (QTPSSW3 or QTPSSW3BLK), Universal Splice Bars (QTPUS10 or QTPUS10BLK), T-Connection or 90o Splice Bars (QTP90TKIT or QTP90TKITBLK)
- Plan Cable Tray Modifications
Review your desired cable tray configuration and identify the specific wires to be cut for bends, tees, or width reductions. Always consult the cutting patterns provided in the manual for your specific tray size and intended modification before making any cuts.
- Cut Cable Tray Wires
Use the Hoffman side action bolt cutter (QTPBC) to make precise cuts. Position the cutting jaws on the cradle wire and cut at an angle away from the new end. First, cut the top side wire, then the remaining side wires. Turn the tray over and cut the bottom wires from the underside, resting the jaws on the cradle wire. Ensure each cut is clean to minimize sharp edges and prevent cable snagging.
- Form a 90-Degree Bend
For a 90-degree bend, cut all side wires at the designated bend location according to the cutting pattern for your tray size. Turn the tray on the uncut side and smoothly bend it upwards until the inside edges closest to the uncut side meet. Secure the bend by fastening it with QTPBNWK Splice Kits and QTPSSW3 Splice Washers as indicated for the tray width.
- Connect Tray Sections
Join modified or straight cable tray sections using QTPBNWK Splice Kits and QTPSSW3 Splice Washers. For configurations like elbows, tees, or width reductions, incorporate QTPUS10 Universal Splice Bars or QTP90TKIT T-Connection Splice Bars as required. Ensure proper alignment of wires and securely fasten all connections.
- Install Cable Tray Supports
Place supports for straight cable tray sections at typical 6-foot (1.5m) intervals. Ensure that supports are positioned within 24 inches (610mm) of any splice on straight sections. Install additional supports around all bends and wherever the cable tray changes levels to provide adequate stability and load bearing.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.