Authorized nVent Distributor
nVent PSS2010B - ProLine V/D Server Cabinet Solid Type 12, fits 2000x1000mm, Black, Steel

nVent PSS2010B ProLine V/D Server Cabinet Solid Type 12, fits 2000x1000mm, Black, Steel

UPC: 783510153687


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent ProLine V/D Server Cabinet, SKU PSS2010B, is engineered for superior protection and operational efficiency in demanding industrial environments. This robust, solid-panel Type 12 enclosure is constructed from durable steel and finished in a sleek black powder coat, offering both resilience and a professional aesthetic. Designed to accommodate equipment up to 2000mm in height and 1000mm in width, it provides ample space for voice and data servers, networking hardware, and other critical IT infrastructure. The ProLine V/D Server Cabinet excels in safeguarding sensitive electronics from harsh conditions. Its Type 12 rating signifies exceptional protection against dust, dirt, and water ingress, making it an ideal choice for applications in manufacturing plants, processing facilities, outdoor enclosures, and other locations where environmental contaminants are a concern. This robust build ensures the longevity and reliability of your IT assets, minimizing downtime and maintenance costs. Flexibility is a key design principle of the ProLine V/D series. While this specific model features solid side panels for maximum environmental sealing, nVent offers a range of optional accessories and configurations to meet diverse cooling and access requirements. For environments with elevated temperatures, the cabinet can be outfitted with optional cutouts and integrated air conditioning units, allowing for precise temperature control of voice/data equipment and servers. This proactive approach to thermal management is crucial for preventing performance degradation and extending the lifespan of high-density computing hardware. Key features and benefits include: * **Superior Environmental Protection:** Type 12 rating ensures protection against dust, dirt, and water, suitable for wet, dusty, or hot industrial settings. * **Durable Steel Construction:** Built with high-quality steel for maximum structural integrity and long-term performance. * **Generous Capacity:** Accommodates 2000x1000mm equipment, providing substantial space for server and network infrastructure. * **Optional Cooling Solutions:** Supports integrated air conditioning for advanced thermal management of sensitive electronics. * **Manufacturer Reliability:** From nVent, a trusted leader in electrical enclosure solutions, ensuring quality and performance. When selecting an industrial server cabinet, factors such as environmental conditions, equipment density, cooling needs, and accessibility are paramount. The nVent ProLine V/D Server Cabinet PSS2010B addresses these critical considerations with its robust design and adaptable features. Professionals in sectors such as manufacturing, telecommunications, utilities, and data centers rely on nVent enclosures for their proven performance and commitment to protecting vital IT assets. The US-made quality of this cabinet further underscores its reliability and adherence to stringent manufacturing standards. Invest in the nVent ProLine V/D Server Cabinet for unparalleled protection and operational continuity for your essential IT equipment.
  • Fully gasketed to keep contaminants away from equipment, reducing maintenance costs
  • Three-point locking handles on all doors provide easy but controlled access; two keys included
  • Rack angles are infinitely adjustable from front to rear for positioning flexibility
  • Mobile base provides easy placement of cabinet
  • Levelers and anti-tip bracket secure cabinet to the floor
  • AC package has cutout for easy in-the-field installation of SpectraCool G-Series Air Conditioner (shipped separately)
  • Mobile base includes casters, levelers and gland plate
  • Gland plate allows easy routing of cable
  • Front window door made of 16 or 14 gauge steel with safety glass window
  • Solid 16 or 14 gauge steel back door

Specifications

Application
Networking, Storage and Data Center
Color
Black
Color
Jet Black
Color Code
RAL 9005
Depth
1 IN
Depth
25 mm
Depth
25
Finish
Powder Coating;Steel/Black
Finish
Powder Coated
Height
78.74 in
Height
2,000 mm
Height
2,000
Material
Mild Steel
Modification Services
Yes
NEMA Rating
12 Indoor, dust-resistant
NEMA Rating
12
Product Family
ProLine
Protection Rating
NEMA Type 12
Style
Solid Sides
Thickness
1.9
Thickness
14 ga
Thickness
1.9 mm
Type
Data Networking Freestanding Cabinets
Weight
73.5 lb
Width
1,000
Width
39.37 in
Width
1,000 mm
Package Dimensions (L x W x H)
79 IN x 40 IN x 3 IN
Package Dimensions (L x W x H)
200.66 cm x 101.6 cm x 7.62 cm
Package Weight (Imperial)
73.500 L
Package Weight (Metric)
33.340 kg
5-port Ethernet Switch

SDI-550

5-port Ethernet Switch
Fiber cable ODC to SC duplex - 670mm

Fiber cable ODC SC Duplex 670mm

Fiber cable ODC to SC duplex - 670mm
Power supply for DIN-rail

PS-60

Power supply for DIN-rail
Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .

ST4803PDGM

Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .
DIN rail is a universal mounting option for electrical and industrial control products such as circuit breakers electrical supplies terminal blocks and more. The rail system is used to stabilize a wide variety of devices and products. Ordering pre-cut DIN rail helps increase productivity and decrease jobsite clutter. On-site Flexibility Streamline custom cuts DIN rail to any length so it is ready to use when it arrives on the jobsite. Additionally DIN rail can be easily removed if relocation is necessary. Features of Custom DIN Rail from Streamline - All cut DIN rail from Streamline is galvanized steel made to eliminate rusting. Streamline ensures that all custom DIN rail orders are: De-burred Custom Length Any quantity 1-1000+ Quick turnaround (typically 2 weeks or less from receipt of order) This mechanical support structure is a must for all electrical parts solutions big or small. DIN rail allows for mounting hardware easily and quickly. These durable and versatile rails make the perfect solution for all mounting applications. Save space time and money with these cost-effective mounting solutions. Order your custom cut DIN rail today!

CUSTOMDIN

DIN rail is a universal mounting option for electrical and industrial control products such as circuit breakers electrical supplies terminal blocks and more. The rail system is used to stabilize a wide variety of devices and products. Ordering pre-cut DIN rail helps increase productivity and decrease jobsite clutter. On-site Flexibility Streamline custom cuts DIN rail to any length so it is ready to use when it arrives on the jobsite. Additionally DIN rail can be easily removed if relocation is necessary. Features of Custom DIN Rail from Streamline - All cut DIN rail from Streamline is galvanized steel made to eliminate rusting. Streamline ensures that all custom DIN rail orders are: De-burred Custom Length Any quantity 1-1000+ Quick turnaround (typically 2 weeks or less from receipt of order) This mechanical support structure is a must for all electrical parts solutions big or small. DIN rail allows for mounting hardware easily and quickly. These durable and versatile rails make the perfect solution for all mounting applications. Save space time and money with these cost-effective mounting solutions. Order your custom cut DIN rail today!
Super-Safeway® Multiple Outlet Box, Extended Depth, 2-Sided, F2 (1/2") Cord Grip Body, with Flip Lids for (2) Duplex Not Included

3085

Super-Safeway® Multiple Outlet Box, Extended Depth, 2-Sided, F2 (1/2") Cord Grip Body, with Flip Lids for (2) Duplex Not Included
Cable Manager, fits 19-inch open rack, Black, Steel

ECK19H

Cable Manager, fits 19-inch open rack, Black, Steel
6U PERF PANEL

PPFS19010BK

6U PERF PANEL
OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL

F62ERLNSNSNM002

OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL
The Mini-Com Flush Mount Modular Patch Panel accepts up to 24 Mini-Com Modules for unshielded applications in 1 RU, and mounts to 19 inch and 23 inch racks and cabinets. The panel mounts flush with the rack and can be identified with adhesive labels and is black.

CPP24FMWBLY

The Mini-Com Flush Mount Modular Patch Panel accepts up to 24 Mini-Com Modules for unshielded applications in 1 RU, and mounts to 19 inch and 23 inch racks and cabinets. The panel mounts flush with the rack and can be identified with adhesive labels and is black.
Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.

CESUM3-C15

Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.
The TX6A™ 10Gig Cat 6A UTP Patch Cord is a 1-Meter, Blue cord constructed of 24 AWG, unshielded, twisted pair stranded, LSZH (60332-1) cable with high-performance modular plugs. Its MaTriX Tape Technology limits alien crosstalk, ensuring 10 Gb/s transmission. The tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.

UTP6AL1MBU

The TX6A™ 10Gig Cat 6A UTP Patch Cord is a 1-Meter, Blue cord constructed of 24 AWG, unshielded, twisted pair stranded, LSZH (60332-1) cable with high-performance modular plugs. Its MaTriX Tape Technology limits alien crosstalk, ensuring 10 Gb/s transmission. The tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.

How to Safely Handle and Install Large Hoffman Enclosures

This guide provides instructions for safely handling and installing large Hoffman enclosures, emphasizing precautions to prevent injury and equipment damage.

Estimated time: 1h

Tools needed:

Forklift, Overhead lifting device (e.g., crane), Slings with load-rated hooks or shackles, ROLL•A•LIFT™ or similar device (for some models)

Supplies needed:

3000 lb.-rated chain or strap (for securing to forklift mast), Rigging equipment (for overhead lifting)

  1. Read Safe Handling Requirements

    Before moving or installing the enclosure, thoroughly read and understand the 'Large Enclosure Safe Handling Requirements' document that accompanied the enclosure. Ensure the route is clear of obstructions and all personnel are at a safe distance.

  2. Prepare for Movement

    Ensure the enclosure is stabilized before removing any strapping. Verify that the lifting equipment (forklift or overhead device) has a sufficient load rating for the enclosure's weight and size. Only trained and authorized personnel should operate the lifting equipment.

  3. Position Forklift Forks

    For forklift handling, spread the forks to the maximum distance or as dictated by the skid width. Enter the skid from the rear (Side A) of the enclosure. Position the enclosure carefully on the forks, keeping the load against the carriage/mast and tilting the load backward towards the mast.

  4. Secure Enclosure to Forklift

    If using a forklift, secure the enclosure to the forklift mast before moving. Insert a 3000 lb.-rated chain or strap through the eye bolts provided on top of the enclosure and fasten it securely to the forklift mast assembly. Ensure sufficient tension to prevent tipping.

  5. Lift and Transport Enclosure

    Lift the enclosure a minimum distance so the skid is just clear of the floor. Start and stop the forklift slowly and gradually, avoiding jerky movements. Drive slowly with the forks carried as low to the ground as possible. Never attempt to move more than one enclosure at a time.

  6. End Loading/Unloading (if applicable)

    For end loading/unloading on trailers, spread forks to match pallet end slot openings and enter from the narrow side (C or D). Secure the enclosure to the forklift mast using chains or straps. Tilt the mast to take weight off the opposite end and slide/push the enclosure as required. Do not use chains or straps to lift the enclosure.

  7. Overhead Lifting (if applicable)

    If using overhead lifting, attach rigging to the eye bolts, ensuring the angle between lifting cables and the vertical does not exceed 45 degrees. Use slings with adequate load-rated hooks or shackles. Ensure the load rating of the lifting device and rigging is sufficient. Do not use ropes or cables through eye bolts.

  8. Final Placement

    Once the enclosure is at its final location, carefully position it. Ensure it is stable and permanently installed according to any specific product instructions not covered in this general handling guide. Refer to the nameplate or datasheet for model-specific details.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.