nVent PP1866 - ProLine Industrial Packages Type 12, 1800x600x600, Lt Gray, Steel
nVent

PP1866

UPC: 783510141882


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent ProLine Industrial Package (SKU: PP1866) is a robust, ready-to-deploy Type 12 enclosure solution designed for industrial environments. Constructed from durable 2.5 mm roll-formed, robotically welded solid steel with fully welded corners, this enclosure features a light gray powder coating. Its generous dimensions are 1800mm (H) x 600mm (W) x 600mm (D), offering ample space for equipment. The package includes a sturdy frame, a solid door with a key lock for security, solid top and rear panels, and a full mounting subpanel for immediate equipment installation. A gland plate is provided for organized cable entry. For simplified handling and installation, four integrated lifting eyes are included. The enclosure meets NEMA Type 12 and IP55 standards, ensuring protection against dust and water ingress. It is manufactured in the USA and meets UL 508A and cUL standards. Side covers for baying configurations are available separately. This enclosure is ideal for protecting electrical and electronic equipment in manufacturing, process control, and data center applications.
  • Durable 2.5 mm roll-formed steel construction
  • Type 12 / IP55 environmental rating
  • Dimensions: 1800mm (H) x 600mm (W) x 600mm (D)
  • Includes solid door with key lock and full mounting subpanel
  • Manufactured in the USA, meets UL 508A and cUL standards
  • Galvanized mounting plates
  • Capped ground studs on door, rear and top panel
  • Integral frame channels support the full weight of the mounting plates
  • Frame thickness 12 gauge/2.5 mm carbon steel powder painted in RAL 7035
  • Door thickness 14 gauge/2.0 mm, carbon steel powder painted – for details please check reference tables

Specifications

Application
Controls and Drives; Power Distribution
Color
Light Gray
Color Code
RAL 7035
Depth
23.62
Depth
600
Finish
Powder Coated
Height
70.87
Height
1,800
Material
Mild Steel
Material
Steel
Modification Services
Yes
NEMA Rating
12 Indoor, dust-resistant
Nema Rating
Type 12
Product Family
ProLine
Protection Rating
NEMA Type 12
Series
ProLine Industrial Packages
Size
1800x600x600mm
Size
1800x600x600
Type
Single Door
Weight
220 lb
Width
23.62 in
Width
600 mm
Package Dimensions (L x W x H)
30.5 IN x 30.5 IN x 78 IN
Package Dimensions (L x W x H)
77.47 cm x 77.47 cm x 198.12 cm
Package Weight (Imperial)
220.000 L
Package Weight (Metric)
99.792 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the PF1885 Enclosure

This guide provides step-by-step instructions for safely installing the PF1885 enclosure, ensuring proper handling and setup.

Estimated time: 1h

Tools needed:

Forklift, Screwdriver, Multimeter

Supplies needed:

3000 lb-rated chain or strap, Mounting screws

  1. Prepare the installation area

    Clear the installation route of all obstructions and ensure that workers are positioned at a safe distance from the enclosure's height.

  2. Secure the enclosure for transport

    Using a forklift, insert a 3000 lb-rated chain or strap through the eye bolts on top of the enclosure and securely fasten it to the forklift mast to prevent tipping during transport.

  3. Lift and position the enclosure

    Carefully lift the enclosure with the forklift, ensuring it is clear of the ground. Position it at the designated installation site, maintaining caution to avoid contact with fixed objects.

  4. Mount the enclosure

    Secure the enclosure to the mounting surface using the provided mounting screws, ensuring it is level and firmly attached.

  5. Verify installation

    Check that the enclosure is stable and securely mounted. Use a multimeter to verify any electrical connections if applicable.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.