nVent MCS20066R5 Modular Single Door, MCS with Plate, 2000x600x600mm, Light Gray, Mild Steel
UPC: 783510495329
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Material: Frame: 1.5 mm painted steel. Door: 2 mm painted steel. Rear, roof and side panels: 1.5 mm painted steel. Mounting plate: 3 mm galvanized steel. Bottom plates: 1 mm galvanized steel.
- Frame: Seam welded reversed open profiles with 25 mm hole pattern, according to DIN 43660. Including integrated external hole pattern.
- Door: Mounted with four hinges allowing left or right hand opening. Including door frame with 25 mm hole pattern.
- Rear panel: Fitted by M6 torx screws. Standard facilities for rear door mounting. RD version comes with rear door instead of rear panel.
- Side panels: Supplied as an accessory.
- Roof panel: Removable.
- Lock: Espagnolette 4-point locking system. Does not interfere with the enclosure inner space. Standard double-bit lock with 3 mm insert. Standard inserts, cylinders, lift handles and T-handles are available as accessories.
- Bottom plates: Consists of three or four (D>600) pieces.
- Mounting plate: Double folded and slides into position. Adjustable in depth by steps of 25 mm, with the MPD02 accessory. Supplied, attached on the outside of the enclosure packaging.
- Earthing: All panels are earthed through their fittings and are equipped with a separate earthing stud.
Specifications
Application | Factory Automation and Process Control; Controls and Drives |
Application | Controls and Drives;Factory Automation and Process Control |
Body Thickness | 1.5 mm |
Body Thickness | 16 ga |
Cable Enclosures Included | No |
Cable Entry | No |
Color | Gray |
Color | Grey |
Color | Light Gray |
Color Code | RAL 7035 |
Construction | Body: 16 gauge Door: 14 gauge |
Depth | 23.62 in |
Depth | 600 mm |
Depth | 600 |
Door Thickness | 14 ga |
Finish | Powder Coated |
Finish | Powder Coating |
Height | 2,000 mm |
Height | 78.74 in |
Height | 2,000 |
IP Rating | IP55 |
Material | Mild Steel |
Max Mounting Depth | 22 in |
Max Mounting Depth | 11.1 in |
Mounting | Free Standing |
Mounting Plate Height | 1,894;74.57 mm;mm |
Mounting Plate Included | Yes |
Mounting Plate Width | 19.45 in |
NEMA Rating | 12 |
NEMA Rating | NEMA Type 12 |
Protection Rating | NEMA Type 12 |
Rear Door Included | No |
Rear Panel Included | Yes |
Size | 2000x600x600mm |
Size | 78.74 x 23.62 x 23.62 inch |
Type | Mild Steel Modular Industrial Enclosures |
Weight | 245.59 lb |
Weight | 32 lbs./100ft |
Weight | 224.87 lb |
Width | 23.62 in |
Width | 600 mm |
Package Dimensions (L x W x H) | 24.25 IN x 24 IN x 79.12 IN |
Package Dimensions (L x W x H) | 61.595 cm x 60.96 cm x 200.9648 cm |
Package Weight (Imperial) | 245.590 L |
Package Weight (Metric) | 111.400 kg |

LH38
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
LN43DA
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
LT20D-NEW
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, GreyFrequently Asked Questions
What is the protection degree of the MCS enclosure range?
The MCS enclosure range has an IP 55 protection degree, preventing water and dust from entering.
What industry standards does the MCS20066R5 comply with?
It is UL 508A Listed Type 12, cUL Listed Type 12, NEMA/EEMAC Type 12, CSA Type 12, and IEC 62208 IP55 compliant.
What materials are used in the construction of this enclosure?
The frame, rear, roof, and side panels are 1.5 mm painted steel, the door is 2 mm painted steel, and the mounting plate is 3 mm galvanized steel.
What are the dimensions of the MCS20066R5 enclosure?
The enclosure measures 2000mm in height, 600mm in width, and 600mm in depth.
What is the color and finish of the enclosure?
The enclosure is finished in RAL 7035 structured powder coating, which is a light gray color.
What is the weight of the MCS20066R5 enclosure?
The enclosure weighs 224.87lb.
Is a mounting plate included with the enclosure?
Yes, a mounting plate is included with the enclosure.
What is the IK rating for this enclosure?
The enclosure complies with IK 10 protection.
How is the door of the enclosure mounted and can it open either way?
The door is mounted with four hinges, allowing for either left or right-hand opening.
What type of locking system does the enclosure feature?
It features an Espagnolette 4-point locking system with a standard double-bit lock and 3 mm insert.
How to Install the MCS20066R5 Controller
This guide provides step-by-step instructions for installing and configuring the MCS20066R5 Controller, ensuring proper mounting, wiring, and initial setup.
Estimated time: 1h
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Wire connectors, Floor plate (if necessary)
- Prepare the installation area
Ensure the installation area is clean and free of debris. If mounting on a combustible surface, install a floor plate of at least 1.43 mm galvanized or 1.6 mm uncoated steel, extending at least 150 mm beyond the equipment on all sides.
- Mount the controller
Secure the MCS20066R5 Controller to the mounting plate using the provided mounting screws. Ensure the controller is level and firmly attached.
- Connect the wiring
Use wire connectors to connect the power and communication cables to the appropriate terminals on the controller. Verify all connections are secure and correctly oriented.
- Power on the controller
Turn on the power supply to the controller and observe the indicator lights to ensure the unit is functioning properly.
- Perform initial configuration
Access the controller's configuration interface using the provided software or web interface. Follow the on-screen instructions to set up the basic parameters.
- Calibrate the controller
Follow the calibration procedure outlined in the user manual to ensure the controller operates within specified parameters. Use a multimeter to verify output signals if necessary.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.