Contact for Pricing
Overview
- Material: Frame: 1.5 mm painted steel. Door: 2 mm painted steel. Rear, roof and side panels: 1.5 mm painted steel. Mounting plate: 3 mm galvanized steel. Bottom plates: 1 mm galvanized steel.
- Frame: Seam welded reversed open profiles with 25 mm hole pattern, according to DIN 43660. Including integrated external hole pattern.
- Door: Mounted with four hinges allowing left or right hand opening. Including door frame with 25 mm hole pattern.
- Rear panel: Fitted by M6 torx screws. Standard facilities for rear door mounting. RD version comes with rear door instead of rear panel.
- Side panels: Supplied as an accessory.
- Roof panel: Removable.
- Lock: Espagnolette 4-point locking system. Does not interfere with the enclosure inner space. Standard double-bit lock with 3 mm insert. Standard inserts, cylinders, lift handles and T-handles are available as accessories.
- Bottom plates: Consists of three or four (D>600) pieces.
- Mounting plate: Double folded and slides into position. Adjustable in depth by steps of 25 mm, with the MPD02 accessory. Supplied, attached on the outside of the enclosure packaging.
- Earthing: All panels are earthed through their fittings and are equipped with a separate earthing stud.
Specifications
Application | Factory Automation and Process Control; Controls and Drives |
Application | Controls and Drives;Factory Automation and Process Control |
Body Thickness | 16 ga |
Body Thickness | 1.5 mm |
Cable Enclosures Included | No |
Cable Entry | No |
Color | Light Gray |
Color | Gray |
Color | Grey |
Color Code | RAL 7035 |
Construction | Body: 16 gauge Door: 14 gauge |
Depth | 23.62 |
Depth | 600 |
Depth | 600 mm |
Door Thickness | 14 ga |
Finish | Powder Coating |
Finish | Powder Coated |
Height | 1,800 mm |
Height | 70.87 |
Height | 1,800 |
IP Rating | IP55 |
Material | Mild Steel |
Material | Mild Steel with Painted Finish |
Max Mounting Depth | 11.1 in |
Max Mounting Depth | 22 in |
Mounting | Free Standing |
Mounting Plate Height | 1,694;66.7 mm;mm |
Mounting Plate Included | Yes |
Mounting Plate Width | 19.45 in |
Mounting Type | Floor-standing, Modular Combinable |
Mounting Type | Floor-Stand |
NEMA Rating | NEMA Type 12 |
NEMA Rating | 12 |
Nema Rating | Type 4, Type 12, Type 13 |
Protection Rating | NEMA Type 12 |
Rear Door Included | No |
Rear Panel Included | Yes |
Series | MCS |
Size | 70.87 x 23.62 x 23.62 inch |
Size | 1800x600x600mm |
Type | Mild Steel Modular Industrial Enclosures |
Weight | 207.23 lb |
Weight | 225.89 lb |
Weight | 32 lbs./100ft |
Width | 23.62 in |
Width | 600 mm |
Package Dimensions (L x W x H) | 24.25 IN x 24 IN x 71.24 IN |
Package Dimensions (L x W x H) | 61.595 cm x 60.96 cm x 180.9496 cm |
Package Weight (Imperial) | 225.890 L |
Package Weight (Metric) | 102.464 kg |

BX4
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
LH38
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
LN43DA
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
LT20D-NEW
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, GreyHow to Install the MCS18066R5 Controller
This guide provides step-by-step instructions for installing and configuring the MCS18066R5 Controller, ensuring proper setup and functionality.
Estimated time: 1h
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Wire connectors, Cable ties
- Mount the controller
Secure the MCS18066R5 controller to a suitable surface using the provided mounting screws. Ensure it is level and firmly attached.
- Connect the power supply
Using wire connectors, connect the power supply wires to the designated terminals on the controller. Ensure the connections are secure and insulated.
- Wire the input/output connections
Connect the input and output devices to the corresponding terminals on the controller. Use a multimeter to verify that all connections are correct and functioning.
- Configure the controller settings
Power on the controller and access the configuration menu. Set the desired parameters according to the application requirements.
- Calibrate the controller
Follow the calibration procedure outlined in the user manual to ensure accurate readings and performance. Adjust settings as necessary.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.