The nVent ProLine G2 Industrial Package (SKU: P2K2085) is a fully integrated, ready-to-deploy Type 12 enclosure designed to streamline industrial control and electrical housing needs. Engineered for durability and compliance, this pre-assembled package eliminates the complexity of sourcing individual components, reducing procurement time and ensuring compatibility. The enclosure features a robust steel construction with a light gray finish, providing superior corrosion resistance and visual identification in demanding environments. A single part number encompasses all essential elements: a sturdy frame, solid door with handle and key lock, solid top and rear cover, full mounting subpanel, gland plate, and four integrated lifting eyes for safe and efficient handling during installation or relocation. Side covers, sold separately, enable seamless joining or baying applications, offering scalability for expanding system configurations. Industrial enclosures like the ProLine G2 Type 12 are critical for protecting sensitive electrical and electronic components from dust, dirt, and non-corrosive liquids while maintaining NEMA Type 12 compliance. These enclosures are indispensable in manufacturing plants, food and beverage processing facilities, pharmaceutical production, and wastewater treatment plants, where environmental contaminants pose constant threats to operational integrity. The ProLine G2 package is particularly well-suited for housing PLCs, motor controllers, variable frequency drives (VFDs), and other automation hardware, ensuring reliable performance in harsh industrial settings. Its modular design allows for easy integration into existing control panels or as part of new installations, reducing downtime during upgrades or maintenance cycles. Professionals in electrical engineering, panel building, and facility management rely on nVent’s ProLine G2 series for its engineering rigor and adherence to industry standards. The inclusion of a full mounting subpanel simplifies internal component organization, while the gland plate accommodates cable entry without compromising enclosure integrity. The solid door with key lock enhances security, protecting critical systems from unauthorized access or tampering. Installation is straightforward, with pre-drilled holes and lifting eyes designed for compatibility with standard material handling equipment, minimizing on-site labor and reducing project timelines. nVent, a global leader in electrical and thermal management solutions, brings decades of expertise to the ProLine G2 series. The company’s commitment to innovation and quality is reflected in the enclosure’s robust construction, which meets or exceeds UL, cUL, and IEC standards. Whether deployed in a factory automation line, a renewable energy substation, or a data center cooling system, the ProLine G2 Industrial Package delivers uncompromising protection and operational efficiency. For engineers and procurement teams seeking a turnkey solution that combines reliability, compliance, and ease of installation, the nVent ProLine G2 Type 12 (P2K2085) stands as a trusted choice in industrial enclosure systems.
  • 12-gauge (2.5 mm) roll-formed steel with welded corners, and hybrid frame profile for superior performance under load
  • Frame features a 25-mm DIN standard, alternating rectangular and round hole pattern
  • Enclosures with a width of 1200mm or less have a single-piece rear cover, and can accommodate a fully-recessed mounting subpanel; enclosures with a width of greater than 1200mm have two rear covers that affix to a removable center upright/vertical combina
  • Gasket is seamless polyurethane providing a water-tight, dust-tight seal against moisture and contaminants; UL component recognized, CSA compliant
  • Door bar system present on all doors (including window doors)
  • Single/primary door includes Smooth Glide Latching System, 3-point roller latch system with timed latch engagement, for enclosures greater than or equal to 1000 mm in height; system ensures a solid and repeatable seal with a low closure force
  • 2-door enclosures include overlapping double doors to provide full-width open front, with a secondary door that latches with two levers
  • Reversible hinging on single doors (default left hinge), and on overlapping double doors (default right door primary door)
  • Two grounding studs present on each door
  • Low-Profile Flush Swing Handle with key lock on standard versions; double bit lock on 'E' versions; other handle options available (sold separately)

Specifications

Application
Controls and Drives; Power Distribution
Color
Light Gray
Color Code
RAL 7035
Depth
19.88
Depth
505
Door Quantity
1
Finish
Powder Coated
Height
78.82
Height
2,002
Material
Mild Steel
Max Rack Mount Unit
42
Max Subpanel Size
1906 x 728 mm
Max Subpanel Size
75.0 x 28.7 in
Product Family
ProLine
Type
Mild Steel Modular Industrial Enclosures
Weight
341 lb
Width
31.8
Width
808
Package Dimensions (L x W x H)
37.5 IN x 30 IN x 87 IN
Package Dimensions (L x W x H)
95.25 cm x 76.2 cm x 220.98 cm
Package Weight (Imperial)
341.000 L
Package Weight (Metric)
154.678 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

Frequently Asked Questions

What is the load rating of the ProLine G2 frame?

The ProLine G2 frame has a 15% higher load rating than the competition.

What is the maximum weight the subpanel can hold?

The subpanel can hold greater than 45% more weight than previous models.

What materials are used in the ProLine G2 frame?

The frame is made of 12 gauge (2.5 mm) roll-formed steel.

What is the weight capacity of the mobile base?

The mobile base can support a load-bearing capacity of 1000 lb. (453.6 kg).

What are the available frame sizes for ProLine G2?

Frame heights range from 600 mm to 2200 mm, with various widths and depths.

How can I customize my ProLine G2 enclosure?

You can select from over 400 standard components and accessories to create a custom solution.

What safety features are included with ProLine G2?

Safety features include mechanical and electrical interlocks, as well as anti-tip brackets.

What type ratings are available for ProLine G2?

ProLine G2 is available in Type 12 and Type 3R ratings.

What are the EMC options for ProLine G2?

EMC options are available for various components, including frames, covers, and doors.

How do I install the internal components?

Internal components can be mounted using grid straps and various mounting brackets provided.

How to Install the P2BGP108 Controller

This guide provides step-by-step instructions for installing and configuring the P2BGP108 Controller.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2BGP108 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the wiring

    Use terminal connectors to connect the power supply and input/output wires to the appropriate terminals on the controller. Follow the wiring diagram provided in the documentation.

  3. Verify connections

    Use a multimeter to check the voltage at the power terminals to ensure proper connection. Confirm that all connections are secure and correct.

  4. Configure the controller

    Access the controller's configuration interface via a web browser or dedicated software. Input the necessary settings as per your application requirements.

  5. Calibrate the controller

    Follow the calibration procedure outlined in the documentation to ensure the controller operates within specified parameters.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.