The nVent ProLine G2 Industrial Packages (SKU: P2K18104) offer a streamlined, ready-to-deploy enclosure solution designed for demanding industrial environments. This Type 12 rated package eliminates the need for separate component ordering, providing a complete, integrated system with a single part number. Constructed from durable steel and finished in a light gray powder coating, this enclosure is built to withstand harsh conditions and protect sensitive electrical and electronic equipment. The ProLine G2 Industrial Package includes a robust frame, solid door(s) with a secure handle and key lock, a solid top, a solid rear cover, a full mounting subpanel for component installation, a gland plate for cable entry, and four lifting eyes for safe and easy handling and installation. This comprehensive kit ensures that essential enclosure components are readily available, significantly reducing procurement time and assembly complexity. Side covers are available separately to facilitate seamless joining or baying of multiple enclosures, allowing for scalable system configurations. Engineered for superior protection, the Type 12 rating signifies suitability for indoor use where protection against falling dirt and dripping of non-corrosive liquids is required. This makes the ProLine G2 an ideal choice for a wide array of industrial applications, including control panels, automation systems, power distribution, and network infrastructure within manufacturing plants, processing facilities, and other industrial settings. Key features and benefits of the nVent ProLine G2 Industrial Package include: * **Complete Solution:** All necessary components are included for immediate deployment, saving time and reducing ordering errors. * **Robust Construction:** Made from high-quality steel for exceptional durability and longevity. * **Type 12 Protection:** Offers reliable protection against dust and dripping liquids, ensuring equipment safety. * **Generous Dimensions:** The 1800x1000x400 mm size provides ample space for mounting various electrical and electronic components. * **Enhanced Security:** Features a handle and key lock for secure access control. * **Versatile Installation:** Includes a full mounting subpanel and gland plate, with lifting eyes for ease of handling. * **Scalability:** Designed for integration with other enclosures through separately ordered side covers. As a trusted manufacturer, nVent (formerly Hoffman) is renowned for its commitment to quality and innovation in enclosure solutions. The ProLine G2 series embodies this dedication, offering reliable performance and ease of use for professionals in electrical, automation, and industrial control sectors.
  • 12-gauge (2.5 mm) roll-formed steel with welded corners, and hybrid frame profile for superior performance under load
  • Frame features a 25-mm DIN standard, alternating rectangular and round hole pattern
  • Enclosures with a width of 1200mm or less have a single-piece rear cover, and can accommodate a fully-recessed mounting subpanel; enclosures with a width of greater than 1200mm have two rear covers that affix to a removable center upright/vertical combina
  • Gasket is seamless polyurethane providing a water-tight, dust-tight seal against moisture and contaminants; UL component recognized, CSA compliant
  • Door bar system present on all doors (including window doors)
  • Single/primary door includes Smooth Glide Latching System, 3-point roller latch system with timed latch engagement, for enclosures greater than or equal to 1000 mm in height; system ensures a solid and repeatable seal with a low closure force
  • 2-door enclosures include overlapping double doors to provide full-width open front, with a secondary door that latches with two levers
  • Reversible hinging on single doors (default left hinge), and on overlapping double doors (default right door primary door)
  • Two grounding studs present on each door
  • Low-Profile Flush Swing Handle with key lock on standard versions; double bit lock on 'E' versions; other handle options available (sold separately)

Specifications

Application
Controls and Drives; Power Distribution
Color
Light Gray
Color Code
RAL 7035
Depth
15.94
Depth
405
Door Quantity
1
Finish
Powder Coated
Height
70.94
Height
1,802
Material
Mild Steel
Max Rack Mount Unit
38
Max Subpanel Size
1706 x 928 mm
Max Subpanel Size
67.2 x 36.5 in
Product Family
ProLine
Type
Mild Steel Modular Industrial Enclosures
Weight
379 lb
Width
39.67
Width
1,008
Package Dimensions (L x W x H)
46.5 IN x 26 IN x 78 IN
Package Dimensions (L x W x H)
118.11 cm x 66.04 cm x 198.12 cm
Package Weight (Imperial)
379.000 L
Package Weight (Metric)
171.914 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

Frequently Asked Questions

What are the available frame heights?

Available frame heights include 600, 800, 1000, 1200, 1400, 1600, 1800, 2000, and 2200 mm.

What is the load rating of the ProLine G2 frame?

The ProLine G2 frame has a 15% higher load rating than the competition.

What safety features are included in the ProLine G2?

Safety features include mechanical and electrical interlocks to prevent unauthorized access and ensure safe operation.

What materials are used for the ProLine G2 frame?

The frame is made of 12 gauge (2.5 mm) roll-formed steel with fully welded solid steel corner blocks.

What is the maximum weight the subpanel can hold?

The subpanel can hold greater than 45% more weight than previous models.

What type ratings are available for the ProLine G2?

The ProLine G2 is available in Type 12 and Type 3R ratings.

What is the maximum load capacity for mobile bases?

The mobile base has a load-bearing capacity of 1000 lb (453.6 kg).

What options are available for cable management?

Options include cable entry cabinets, vertical tie-downs, and various cable management accessories.

How can I configure my ProLine G2 enclosure?

You can select components and send your configuration to an nVent HOFFMAN representative for assistance.

How do I maintain the ProLine G2 enclosure?

Regular inspections and cleaning of the enclosure and its components are recommended to ensure optimal performance.

How to Install the P2K18104 Controller

This guide provides step-by-step instructions for installing and configuring the P2K18104 Controller for optimal performance.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the P2K18104 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the power supply

    Use terminal connectors to connect the power supply wires to the designated power input terminals on the controller. Verify the polarity is correct to avoid damage.

  3. Wire the input/output connections

    Connect the necessary input and output devices to the corresponding terminals on the controller. Ensure all connections are secure and insulated.

  4. Configure the controller settings

    Using the provided software, connect to the controller via USB or Ethernet and configure the settings according to your application requirements.

  5. Calibrate the controller

    Follow the calibration procedure outlined in the software to ensure accurate readings and performance. Test the system to confirm proper operation.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.