Authorized nVent Distributor
nVent MCS20068R5 - Modular Single Door, MCS with Plate, 2000x600x800mm, Light Gray, Mild Steel

nVent MCS20068R5 Modular Single Door, MCS with Plate, 2000x600x800mm, Light Gray, Mild Steel

UPC: 783510495473


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The **nVent MCS20068R5** is a high-performance, modular single-door floor-standing enclosure designed to provide superior protection for sensitive electrical and electronic components in demanding industrial environments. Engineered from durable mild steel and finished in a durable light gray powder coat, this enclosure meets **IP55** ingress protection standards, ensuring robust defense against dust ingress and water jets from any direction. Part of nVent’s renowned **MCS (Modular Control System) enclosure range**, the MCS20068R5 is ideal for applications requiring reliable, off-the-shelf protection with the flexibility to integrate into larger modular systems. With a compact footprint of **2000x600x800mm**, this enclosure is engineered for space-efficient installation in control rooms, automation hubs, manufacturing floors, and utility stations where equipment longevity and operational continuity are critical. **Key Features and Benefits** The MCS20068R5 stands out for its **modular design**, allowing seamless integration with other MCS enclosures to create scalable, customizable solutions that grow with your operational needs. Its **single-door configuration** simplifies access for maintenance and upgrades while maintaining a secure seal when closed. The **IP55-rated enclosure** prevents the ingress of dust particles and low-pressure water jets, making it suitable for use in harsh or outdoor-adjacent environments such as food processing plants, chemical facilities, and water treatment plants. The **mild steel construction** offers excellent structural integrity and electromagnetic shielding, protecting sensitive electronics from interference and physical damage. **Industry Applications and Use Cases** This enclosure is purpose-built for industries where **reliability, safety, and compliance** are non-negotiable. In **manufacturing**, it houses PLCs, HMIs, and motor control centers, safeguarding critical automation systems from contaminants and mechanical stress. In **energy and utilities**, it protects power distribution components, battery management systems, and telemetry equipment in substations and remote monitoring stations. The **transportation sector** leverages MCS enclosures to secure signaling systems, traffic control electronics, and communication hubs in rail yards and highway infrastructure. Additionally, the **water and wastewater industry** relies on these enclosures to shield instrumentation and control panels in treatment plants and pumping stations, where exposure to moisture and particulates is constant. **Installation and Integration Considerations** Designed for **ease of installation**, the MCS20068R5 features pre-drilled mounting holes and compatible accessories such as mounting plates, gland plates, and ventilation kits. Professionals appreciate the **tool-less access** provided by the single-door design, which reduces downtime during servicing or component replacement. For larger installations, the modular nature of the MCS range allows for **side-by-side or stacked configurations**, enabling engineers to build custom control centers that meet specific spatial and functional requirements. nVent provides comprehensive installation guides and CAD models to streamline planning and ensure proper alignment and sealing. **Why Choose nVent for Industrial Enclosures?** As a global leader in thermal management and electrical protection solutions, **nVent** brings decades of expertise to the design and manufacturing of industrial enclosures. The MCS series reflects the company’s commitment to **durability, innovation, and compliance** with international standards such as IEC 62208 and UL 50E. Customers trust nVent for its **consistent quality**, extensive product range, and responsive technical support. Whether deployed in a factory automation line, a renewable energy site, or a municipal infrastructure project, the **MCS20068R5** delivers the performance and protection needed to keep operations running smoothly—minimizing downtime, reducing maintenance costs, and ensuring long-term reliability. **Proven Performance, Off-the-Shelf Availability** Available in multiple sizes and configurations, the MCS20068R5 can be procured directly from nVent’s global distribution network, ensuring fast lead times and reliable availability. This makes it an ideal choice for OEMs, system integrators, and facility managers seeking a **cost-effective, high-quality enclosure solution** without compromising on protection or performance. Invest in the **nVent MCS20068R5** and safeguard your critical electronics with a product built to endure the toughest industrial conditions.
  • Material: Frame: 1.5 mm painted steel. Door: 2 mm painted steel. Rear, roof and side panels: 1.5 mm painted steel. Mounting plate: 3 mm galvanized steel. Bottom plates: 1 mm galvanized steel.
  • Frame: Seam welded reversed open profiles with 25 mm hole pattern, according to DIN 43660. Including integrated external hole pattern.
  • Door: Mounted with four hinges allowing left or right hand opening. Including door frame with 25 mm hole pattern.
  • Rear panel: Fitted by M6 torx screws. Standard facilities for rear door mounting. RD version comes with rear door instead of rear panel.
  • Side panels: Supplied as an accessory.
  • Roof panel: Removable.
  • Lock: Espagnolette 4-point locking system. Does not interfere with the enclosure inner space. Standard double-bit lock with 3 mm insert. Standard inserts, cylinders, lift handles and T-handles are available as accessories.
  • Bottom plates: Consists of three or four (D>600) pieces.
  • Mounting plate: Double folded and slides into position. Adjustable in depth by steps of 25 mm, with the MPD02 accessory. Supplied, attached on the outside of the enclosure packaging.
  • Earthing: All panels are earthed through their fittings and are equipped with a separate earthing stud.

Specifications

Application
Controls and Drives;Factory Automation and Process Control
Body Thickness
1.5 mm
Body Thickness
16 ga
Cable Enclosures Included
No
Cable Entry
No
Color
Gray
Color
Grey
Color
Light Gray
Color Code
RAL 7035
Construction
Body: 16 gauge Door: 14 gauge
Depth
800
Depth
31.5 in
Depth
800 mm
Door Thickness
14 ga
Finish
Powder Coated
Finish
Powder Coating
Height
78.74 in
Height
2,000 mm
Height
2,000
Material
Mild Steel
Max Mounting Depth
11.1 in
Max Mounting Depth
29.88 in
Mounting
Free Standing
Mounting Plate Height
1,894;74.57 mm;mm
Mounting Plate Included
Yes
Mounting Plate Width
19.45 in
NEMA Rating
12
NEMA Rating
NEMA Type 12
Protection Rating
NEMA Type 12
Rear Door Included
No
Rear Panel Included
Yes
Size
78.74 x 23.62 x 31.5 inch
Type
Mild Steel Modular Industrial Enclosures
Weight
263.34 lb
Weight
235.89 lb
Weight
32 lbs./100ft
Width
23.62 in
Width
600 mm
Package Dimensions (L x W x H)
32.12 IN x 24 IN x 79.12 IN
Package Dimensions (L x W x H)
81.5848 cm x 60.96 cm x 200.9648 cm
Package Weight (Imperial)
263.340 L
Package Weight (Metric)
119.451 kg
Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht

EP3030

Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
External operation handle 0-1 type S3 Black IP65

14333111

External operation handle 0-1 type S3 Black IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

Frequently Asked Questions

What are the dimensions of the MCS20068R5 enclosure?

The enclosure has dimensions of 2000mm height, 600mm width, and 800mm depth.

What is the protection degree of this enclosure?

The enclosure has an IP 55 protection degree, complying with TYPE 12 and IK 10 standards.

What materials are used in the construction of the enclosure?

The frame, rear, roof, and side panels are 1.5 mm painted steel, the door is 2 mm painted steel, and the mounting plate is 3 mm galvanized steel.

What is the color and finish of the enclosure?

The enclosure is finished in RAL 7035 structured powder coating, which is a light gray color.

Does the enclosure come with a mounting plate?

Yes, a mounting plate is included with the enclosure, made of 3 mm galvanized steel.

How is the door mounted and can it open in either direction?

The door is mounted with four hinges and allows for either left or right-hand opening.

What type of locking system does the enclosure use?

It features an Espagnolette 4-point locking system with a standard double-bit lock and a 3 mm insert.

Are side panels included with the standard delivery?

No, side panels are supplied as an accessory and must be ordered separately to maintain the protection rating.

How are the bottom plates configured?

The bottom plates consist of three or four pieces, depending on the enclosure depth.

How is the mounting plate adjusted in depth?

The mounting plate can be adjusted in depth by steps of 25 mm using the MPD02 accessory.

How to Install the MCS20068R5 Controller

This guide provides step-by-step instructions for installing and configuring the MCS20068R5 Controller, ensuring proper mounting, wiring, and initial setup.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the MCS20068R5 Controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the wiring

    Use terminal connectors to connect the power supply and input/output wires to the corresponding terminals on the controller. Ensure all connections are tight and secure.

  3. Verify the connections

    Use a multimeter to check the voltage at the power terminals to ensure proper power supply. Confirm that all input/output connections are correctly wired.

  4. Configure the controller settings

    Access the controller's configuration interface and set the desired parameters according to your application requirements. Save the settings.

  5. Calibrate the controller

    Perform any necessary calibration procedures as specified in the user manual to ensure accurate operation.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.