Overview

The nVent MCD (Modular Combinable Double Door) enclosure system, specifically the MCD20126PERDR5 model, offers a robust and space-efficient solution for housing critical electrical and electronic components in demanding industrial environments. This mild steel, floor-standing enclosure is engineered with a double-door configuration, a design choice that significantly enhances accessibility and operational efficiency, particularly in confined installation spaces. Unlike single-door enclosures that can obstruct pathways when fully opened, the dual-door design of the MCD minimizes its footprint, allowing for easier integration into existing plant layouts and tighter production floors. This thoughtful design also distributes the weight load across two doors, increasing their overall loading capacity and simplifying access to internal equipment. The MCD20126PERDR5 boasts an IP55 protection degree, signifying superior resistance against dust ingress and protection from water jets. This high level of ingress protection ensures that sensitive internal components remain safeguarded from environmental contaminants, making it an ideal choice for a wide array of applications across various industries, including manufacturing, process control, power distribution, and telecommunications. The durable mild steel construction provides inherent mechanical strength and resilience, capable of withstanding the rigors of industrial operation. Key features and benefits of the nVent MCD enclosure include: * **Space Optimization:** The double-door design is paramount for installations where space is at a premium, preventing operational obstructions. * **Enhanced Accessibility:** Two doors provide more convenient and less restrictive access to internal equipment for maintenance and configuration. * **Increased Load Capacity:** The load is divided between two doors, allowing for heavier internal components or more extensive equipment mounting. * **Superior Environmental Protection:** An IP55 rating ensures protection against dust and water, critical for component longevity and system reliability. * **Durable Construction:** Manufactured from high-quality mild steel for exceptional strength and longevity. * **Modular Design:** The MCD range is designed for combinability, allowing for expansion and customization to meet evolving project requirements. * **Rear Door Access:** This specific model includes a rear door, offering an alternative or supplementary access point for maintenance or cable management. Professionals selecting enclosures for critical infrastructure rely on manufacturers like nVent, known for their commitment to quality, innovation, and adherence to international standards. The MCD series exemplifies this dedication, providing a reliable platform for protecting valuable assets. The UNSPSC code 39121334 categorizes this product within Electrical Enclosures, highlighting its core function in electrical infrastructure management. Manufactured in the US, the MCD20126PERDR5 benefits from stringent quality control and manufacturing expertise, ensuring a product that meets the high expectations of industrial applications. Whether for new installations or upgrades, the nVent MCD enclosure system delivers performance, protection, and practicality.
  • Material: Frame: 1.5 mm painted steel. Doors: 2 mm painted steel. Rear, roof and side panels: 1.5 mm painted steel. Mounting plate: 3 mm galvanized steel. Bottom plates: 1 mm galvanized steel.
  • Frame: Seam welded reversed open profiles with 25 mm hole pattern, according to DIN 43660. Including integrated external hole pattern.
  • Doors: Mounted with four hinges. Including door frame with 25 mm hole pattern. Doors cannot be reversed. Separate doors to be ordered for left hand door locking.
  • Rear panel: Fitted by M6 torx screws. Standard facilities for rear doors mounting. Split rear panels in 1600 mm wide enclosures. RD version comes with rear door instead of rear panel.
  • Side panels: Supplied as an accessory.
  • Roof panel: Removable.
  • Lock: Espagnolette 4-point locking system in the main door and 2-point locking system in the secondary door. Standard double-bit lock with 3 mm insert. Standard inserts, cylinders, lift handles and T-handles are available as accessories.
  • Bottom plates: Consists of three or four (D>600) pieces.
  • Mounting plate: Double folded and slides into position. Adjustable in depth by steps of 25 mm, with the MPD02 accessory. Supplied, attached on the outside of the enclosure packaging.
  • Earthing: All panels are earthed through their fittings and equipped with a separate earthing stud.

Specifications

Body Thickness
16 ga
Color
Gray
Color
Grey
Color Code
RAL 7035
Depth
23.62 in
Depth
600 mm
Door Thickness
14 ga
Finish
Powder Coating
Height
78.74 in
Height
2,000 mm
IP Rating
IP55
Material
Mild Steel
Mounting Plate Included
No
Protection Rating
NEMA Type 12
Rear Door Included
Yes
Rear Panel Included
No
Size
2000x1200x600mm
Type
Mild Steel Modular Industrial Enclosures
Width
1,200 mm
Width
47.24 in
Package Dimensions (L x W x H)
79.12 IN x 47.62 IN x 47.87 IN
Package Dimensions (L x W x H)
200.9648 cm x 120.9548 cm x 121.5898 cm
Package Weight (Imperial)
473.600 L
Package Weight (Metric)
214.825 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

Frequently Asked Questions

What are the dimensions of the MCD20126PERDR5 enclosure?

The enclosure measures 78.74 inches in height, 47.24 inches in width, and 23.62 inches in depth.

What material is the MCD20126PERDR5 enclosure made from?

The enclosure is constructed from mild steel, with painted steel for the frame, doors, rear, roof, and side panels.

What is the protection rating of this enclosure?

The enclosure complies with IP55, Type 12, and IK 10 protection ratings.

Does the enclosure come with a mounting plate?

No, the mounting plate is not included with the standard delivery for this enclosure.

Is a rear door included with the MCD20126PERDR5?

Yes, the RD version of this enclosure comes with a rear door instead of a rear panel.

What type of locking system does the enclosure use?

It features an Espagnolette 4-point locking system on the main door and a 2-point system on the secondary door.

What industry standards does the MCD20126PERDR5 comply with?

It is UL 508A Listed, cUL Listed, NEMA/EEMAC Type 12, and complies with CSA and IEC 62208 standards.

What is the color and finish of the enclosure?

The enclosure has a RAL 7035 light gray structured powder coating finish.

Are side panels included with the enclosure?

No, side panels are supplied as an accessory and must be ordered separately.

What is the door thickness of the enclosure?

The doors of the enclosure are 2 mm thick, which is equivalent to 14ga.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.