Overview

The nVent MCD20126R5 is a robust, floor-standing modular double door enclosure designed for industrial applications. Constructed from durable mild steel, it measures 2000mm in height, 1200mm in width, and 600mm in depth. This enclosure offers IP55 protection, safeguarding internal components from dust and water jets, and meets TYPE 12, 13, and IK10 impact resistance standards. The frame is fabricated from 1.5mm painted steel, while the doors are a more substantial 2mm painted steel. Rear, roof, and side panels are also made of 1.5mm painted steel. A 3mm galvanized steel mounting plate is included for secure equipment installation. The combinable double-door design enhances accessibility and structural integrity, making it suitable for industrial automation, telecommunications, and utility distribution systems. The professional gray finish provides UV resistance. SKU: MCD20126R5. The enclosure includes a rear panel and a mounting plate, delivered on a pallet compatible with baying without removal. Manufactured in the US.
  • Material: Frame: 1.5 mm painted steel. Doors: 2 mm painted steel. Rear, roof and side panels: 1.5 mm painted steel. Mounting plate: 3 mm galvanized steel. Bottom plates: 1 mm galvanized steel.
  • Frame: Seam welded reversed open profiles with 25 mm hole pattern, according to DIN 43660. Including integrated external hole pattern.
  • Doors: Mounted with four hinges. Including door frame with 25 mm hole pattern. Doors cannot be reversed. Separate doors to be ordered for left hand door locking.
  • Rear panel: Fitted by M6 torx screws. Standard facilities for rear doors mounting. Split rear panels in 1600 mm wide enclosures. RD version comes with rear door instead of rear panel.
  • Side panels: Supplied as an accessory.
  • Roof panel: Removable.
  • Lock: Espagnolette 4-point locking system in the main door and 2-point locking system in the secondary door. Standard double-bit lock with 3 mm insert. Standard inserts, cylinders, lift handles and T-handles are available as accessories.
  • Bottom plates: Consists of three or four (D>600) pieces.
  • Mounting plate: Double folded and slides into position. Adjustable in depth by steps of 25 mm, with the MPD02 accessory. Supplied, attached on the outside of the enclosure packaging.
  • Earthing: All panels are earthed through their fittings and equipped with a separate earthing stud.

Specifications

Application
Controls and Drives;Factory Automation and Process Control
Application
Factory Automation and Process Control; Controls and Drives
Body Thickness
16 ga
Body Thickness
1.5 mm
Cable Entry
No
Color
Gray
Color
Grey
Color
Light Gray
Color Code
RAL 7035
Construction
Body: 16 gauge Door: 14 gauge
Depth
600
Depth
600 mm
Depth
23.62 in
Door Thickness
14 ga
Finish
Powder Coating
Finish
Powder Coated
Height
2,000
Height
78.74 in
Height
2,000 mm
IP Rating
IP55
Material
Mild Steel
Max Mounting Depth
11.1 in
Max Mounting Depth
22 in
Mounting
Free Standing
Mounting Plate Height
1,894;74.57 mm;mm
Mounting Plate Included
Yes
Mounting Plate Width
43.07 in
Mounting Type
Floor-standing
NEMA Rating
12
NEMA Rating
NEMA Type 12
Nema Rating
Type 12/Type 13
Protection Rating
NEMA Type 12
Rear Door Included
No
Rear Panel Included
Yes
Series
nVent MCD
Size
2000x1200x600mm
Size
78.74 x 47.24 x 23.62 inch
Type
Mild Steel Modular Industrial Enclosures
Weight
433.53 lb
Width
1,200
Width
1,200 mm
Width
47.24 in
Package Dimensions (L x W x H)
47.62 IN x 24.25 IN x 79.12 IN
Package Dimensions (L x W x H)
120.9548 cm x 61.595 cm x 200.9648 cm
Package Weight (Imperial)
433.530 L
Package Weight (Metric)
196.649 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco

36297702

Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

Frequently Asked Questions

What is the protection degree of the MCD20126R5 enclosure?

The enclosure has an IP55 protection degree, making it well-suited for many applications.

What industry standards does the MCD20126R5 enclosure comply with?

It is UL 508A Listed Type 12, cUL Listed Type 12, NEMA/EEMAC Type 12, CSA Type 12, and IEC 62208 IP55.

What materials are used in the construction of the MCD20126R5 enclosure?

The frame, doors, rear, roof, and side panels are painted steel. The mounting plate is galvanized steel, and bottom plates are galvanized steel.

What are the dimensions of the MCD20126R5 enclosure?

The enclosure measures 78.74 inches in height, 47.24 inches in width, and 23.62 inches in depth.

Is a mounting plate included with the MCD20126R5 enclosure?

Yes, a mounting plate is included. It is 74.57mm in height and 43.07 inches in width.

What is the finish and color of the MCD20126R5 enclosure?

The enclosure has a RAL 7035 structured powder coating in a light gray color.

What is the body and door thickness of the MCD20126R5 enclosure?

The body thickness is 16ga, and the door thickness is 14ga.

What type of locking system does the MCD20126R5 enclosure use?

It features an Espagnolette 4-point locking system on the main door and a 2-point system on the secondary door, with a standard double-bit lock.

Are side panels included with the MCD20126R5 enclosure?

No, side panels are supplied as an accessory and must be ordered separately to maintain the protection rating for individual or assembled cabinets.

How are the panels of the MCD20126R5 enclosure earthed?

All panels are earthed through their fittings and are equipped with a separate earthing stud.

How to Install the MCD20126R5 Controller

This guide provides step-by-step instructions for installing and configuring the MCD20126R5 Controller, ensuring proper mounting, wiring, and initial setup.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the MCD20126R5 controller to the designated mounting surface using the provided mounting screws. Ensure that the controller is level and firmly attached.

  2. Connect the power supply

    Using wire strippers, prepare the power supply wires and connect them to the designated terminals on the controller. Ensure that the connections are secure and insulated to prevent short circuits.

  3. Configure initial settings

    Power on the controller and use the interface to navigate to the configuration menu. Set the required parameters according to your application needs, and save the settings.

  4. Calibrate the controller

    Follow the calibration procedure outlined in the user manual to ensure accurate performance. Use a multimeter to verify output signals during calibration.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.