nVent MAD0801230R5 - Double Door Enclosure, MAD, 31.50x47.24x11.81, Lt Gray, Mild Steel
nVent

MAD0801230R5

UPC: 783510486556


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent MAD0801230R5 double door mild steel enclosure provides a secure and accessible housing solution for industrial electrical and control equipment. Designed for installations with limited frontal clearance, its unique double door design prevents obstructions and improves access to internal components while balancing weight distribution for enhanced door loading capacity and ease of operation. Constructed from 1.5 mm mild steel body with 2 mm mild steel doors, this enclosure delivers robust physical protection. The light gray finish offers a professional aesthetic suitable for industrial environments. With an IP55 protection rating, it safeguards internal equipment against dust ingress and low-pressure water jets, making it ideal for manufacturing, automation, and infrastructure applications. Key features include concealed removable hinges with captive pins, 130° door opening angle, and a three-point espagnolette locking system for enhanced security. The mounting plate is marked vertically at 10 mm intervals for precise equipment positioning, with M8 press-welded studs for secure attachment. Side panels 800 mm and above feature folded edges for additional strength. The gland plate opening at the rear facilitates easier cable management onto the mounting plate.
  • Material: Body: 1.5 mm mild steel. Gland plate: 1.4 mm mild steel. Door: 2 mm mild steel Mounting plate: 2 mm galvanized steel / 2.5 mm MAD1001030R5 and above.
  • Body: Folded and seam welded. Four 8.5 mm diameter holes for wall fixing, pressed out in 20.4 mm diameter × 2 mm depressions, to allow air circulation around the rear part of the enclosure.
  • Door: Surface mounted with 130° opening. Concealed removable hinges with captive pin. Inner M6 welded studs to mount door profiles MMDP. Two removable mounting profiles on the right hand door and two on the left hand door. Sealing is ensured by an injecte
  • Lock: Customized lock with double-bit for easy opening of the door. Double-bit 3 mm insert and 90° movement. Espagnolette three point locking. Other inserts are available as an accessory.
  • Mounting plate: The mounting plate is marked vertically at 10 mm intervals, for easy horizontal positioning of equipment. On the top and bottom there are holes to facilitate cable fixing. Fixed onto M8 press welded studs to the rear of the enclosure. All
  • Gland Plate Opening: Situated at the far rear of the enclosure, to make cabling onto the mounting plate easier.
  • Protection: IP 55, TYPE 12, IK 10. For outdoor installation, the use of a rain hood, ARF, and 100% polyester paint coating plus corrosion protection primer is recommended. Resistance to corrosion must be taken into consideration for outdoor and indoor app
  • Finish: RAL 7035 structured powder coating.
  • Delivery: Enclosure with doors and mounting plate (not included for item numbers ending with PER5). Two door mounting profiles on each door. Gland plate(s) with gasket(s), metallic double-bit 3 mm key, and mounting accessories. Earthing facilities.
  • Mounting plate: All sides, from 800 mm and above, are strengthened by folded edges

Specifications

Application
Controls and Drives;Factory Automation and Process Control
Body Thickness
1.5 mm
Body Thickness
16 ga
Cable Entry
No
Color
Light Gray
Color
Gray
Color
Grey
Color Code
RAL 7035
Construction
Body: 16 gauge Door: 14 gauge
Cubic Capacity
10 in3
Cubic Capacity
163871 mm3
Depth
300 mm
Depth
11.81 in
Door Thickness
14 ga
Finish
Powder Coated
Gland Plate Opening Depth
3.78 in
Gland Plate Opening Width
12.2 in
Gland Plate Opening Width
20.08 in
Gland Plate Type
4
Height
800 mm
Height
31.5 in
Insulation
No
Latch Quantity
1
Material
Mild Steel
Material Quality
Mild Steel
Max Mounting Depth
11.1 in
Mounting
Wall Mounted
Mounting Plate Included
Yes
NEMA Rating
12;13
NEMA Rating
NEMA Type 12 NEMA Type 13
Number of Gland Plate Openings
2
Number Of Outlet
1
Panel Size
30.31 x 45.28 in
Panel Size
72.00 x 72.00 in
Protection Rating
NEMA Type 12
Size
31.5 x 47.24 x 11.81 inch
Type
Mild Steel Wall Mounted Industrial Enclosures
Weight
140.77 lb
Weight
32 lbs./100ft
Width
1,200 mm
Width
47.24 in
With or Without Panel
With
Package Dimensions (L x W x H)
47.62 IN x 31.87 IN x 12.44 IN
Package Dimensions (L x W x H)
120.9548 cm x 80.9498 cm x 31.5976 cm
Package Weight (Imperial)
140.770 L
Package Weight (Metric)
63.853 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the MAD0801230R5 Controller

This guide provides step-by-step instructions for installing and configuring the MAD0801230R5 Controller, ensuring proper wiring and calibration.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Prepare the installation area

    Ensure the installation area is clear and free of debris. If mounting on a combustible surface, install a floor plate of at least 1.43 mm galvanized or 1.6 mm uncoated steel, extending at least 150 mm beyond the equipment on all sides.

  2. Mount the controller

    Secure the MAD0801230R5 Controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  3. Connect the wiring

    Use terminal connectors to connect the power supply and input/output wires to the corresponding terminals on the controller. Verify all connections are secure and correctly oriented.

  4. Power on the controller

    Turn on the power supply to the controller. Use a multimeter to verify that the voltage levels are within the specified range.

  5. Configure the controller settings

    Access the controller's configuration interface and input the necessary parameters according to your application requirements. Save the settings.

  6. Calibrate the controller

    Follow the calibration procedure outlined in the user manual to ensure accurate operation. Adjust settings as necessary based on the calibration results.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.