nVent KBAU6MBNCWCLE - Hazloc Cable Glands for Armored Cable (Ex d/e/tb), Brass, M63x1.5
nVent

KBAU6MBNCWCLE

UPC: 783510306670


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent KBAU6MBNCWCLE is a brass hazardous location cable gland (SKU: KBAU6MBNCWCLE) designed for armored cables in explosive gas and dust environments. Certified for Zone 1, 2, 21, and 22 per ATEX (II2GD Ex d IIC Gb, Ex e IIC Gb, Ex tb IIIC Db) and IECEx standards, this gland meets IEC/EN 60079-0, -1, -7, -31, UL2225, and CSA C22.2 No.60079 series. It features a durable nickel-plated brass construction with a chloroprene seal rated for -40°C to 100°C (-40°F to 212°F). The M63x1.5 metric thread ensures compatibility with standard industrial enclosures. Supplied as a kit with chloroprene washer, locknut, and earth tag, it provides three levels of removable seals for a clamping range of 40.0–52.0 mm (1.57–2.05 in) armor wire diameter. IP66/68 rated for dust and moisture ingress protection, this gland is ideal for oil and gas, chemical processing, mining, and power generation applications where flameproof (Ex d), increased safety (Ex e), or dust-tight (Ex tb) protection is required.
  • Suitable for SWA (steel wire armored), AWA (aluminum wire armored), SWB (steel wire braid), STA (steel tape armored), & shielded cable in flameproof (ex d), increased safety (ex e) and dust (ex tb) applications
  • Allow for double sealing of cable and jacket with upper and lower seals
  • The swivel retainer and grounding cone are adhered to the gland body by the o-rings to prevent any loose parts; to remove, simply pull these components slightly to detach
  • All metric thread cable glands are packaged as kits and includes a chloroprene washer, locknut and earthtag
  • All NPT thread cable glands are packaged as kits. Each kit includes a locknut and earthtag (except for NPT 3/8-in. cable glands which do not include locknut and earthtag)
  • Available in Metric (M) and NPT (N) thread type
  • Operating temperature from -40 C to 100 C with chloroprene seal and -60 C to 130 C with silicon seal

Specifications

Application
Hazardous Environments
Clamping Range Diameter, Lower Seal
0.79-1.26 in
Clamping Range Diameter, Lower Seal
1.57-2.05 in
Clamping Range Diameter, Upper Seal
29.0-41.0 mm
Clamping Range Diameter, Upper Seal
1.85-2.36 in
Color
Unpainted
Finish
Nickel Plated
IP Rating
IP66/68 (EN60529)
Material
Brass
Seal
Chloroprene
Size
M63x1.5
Thread Size
M63 x 1.5
Type
Other Accessories
Weight
4.1 lb
Works With
NEMA / IEC
Package Dimensions (L x W x H)
10 IN x 6.5 IN x 3.25 IN
Package Dimensions (L x W x H)
25.4 cm x 16.51 cm x 8.255 cm
Package Weight (Imperial)
4.100 L
Package Weight (Metric)
1.860 kg
Hazloc Cable Glands for Armored Cable (Ex d/e/tb), Brass, NPT 2"

KBAU6NBNCLE

Hazloc Cable Glands for Armored Cable (Ex d/e/tb), Brass, NPT 2"
BRASS GROUND KIT 375

GRDT375

BRASS GROUND KIT 375
ARCA JIC 10 x 8 x 6 with knockouts, hinged opaque cover, SS latch, padlockable

ARK1086CHSSL

ARCA JIC 10 x 8 x 6 with knockouts, hinged opaque cover, SS latch, padlockable
Double sided electrical box mounting bracket for mounting to either side of a stud. It is made of pre galvanized steel with a stamped construction and silver color. Dimensions are 5 in. height, 6-7/8 in. width, and 3/8 in. depth. It is for use with 1-1/2 in. or 2-1/8 in. deep electrical boxes and 4 in. or 4-11/16 in. square boxes, with 2-1/2, 3-1/2, or 4 in. stud depth.

FBO234DS

Double sided electrical box mounting bracket for mounting to either side of a stud. It is made of pre galvanized steel with a stamped construction and silver color. Dimensions are 5 in. height, 6-7/8 in. width, and 3/8 in. depth. It is for use with 1-1/2 in. or 2-1/8 in. deep electrical boxes and 4 in. or 4-11/16 in. square boxes, with 2-1/2, 3-1/2, or 4 in. stud depth.
Mounting Lugs with Self-Tapping Screws for Boxes Only

LM

Mounting Lugs with Self-Tapping Screws for Boxes Only
6x6x3 Polycarbonate Enclosure NEMA 6P | Standard Hinge | Clear Lid | Integrated Locking Latch | Intergrated Mounting Flange

P6063C

6x6x3 Polycarbonate Enclosure NEMA 6P | Standard Hinge | Clear Lid | Integrated Locking Latch | Intergrated Mounting Flange
End Cover(DSKK 2.5 Series)

D-DSKK2.5-01P-11-00Z(H)

End Cover(DSKK 2.5 Series)

How to Install the KBAU6MBNCWCLE Controller

This guide provides step-by-step instructions for the installation and initial setup of the KBAU6MBNCWCLE controller, ensuring proper wiring and configuration.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the KBAU6MBNCWCLE controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the wiring

    Using wire strippers, prepare the cables and connect them to the appropriate terminals on the controller. Ensure that the connections are tight and secure to prevent any electrical faults.

  3. Configure the controller settings

    Power on the controller and access the configuration menu. Set the desired parameters according to your application requirements, and save the settings.

  4. Calibrate the controller

    Perform a calibration of the controller by following the on-screen instructions. Use a multimeter to verify that the output readings match the expected values.

  5. Verify installation

    After completing the setup, double-check all connections and settings. Ensure that the controller operates correctly by testing its functionality.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.