Contact for Pricing
Overview
- IP55 rated for dust and water protection
- 230V operation with 149 CFM airflow
- Tool-free click-fit installation system
- Easy-access grilles for quick filter replacement
- Durable black finish from nVent
- Similar cut-out sizes as other filter fan manufacturers
- Terminal block connections
- Optional thermostat available to save energy and extend service life
- Hinged grille remains attached after opening
- Size rage from 4 inch (102 mm) to 13 inch (325 mm)
Specifications
Airflow | 149 ft³/min |
Airflow | 253 m³/h |
Ambient Temperature | 14 to 131 deg F |
Amperage Rating | .34/.37 A |
Application | Controls and Drives; Power Distribution |
Color | Graphite Black |
Color Code | RAL 9011 |
Depth | 162 mm |
Depth | 6.36 in |
Finish | Smooth Matte |
Flow Rate | 149 CFM |
Height | 12.8 in |
Height | 325 mm |
Housing Material | Non-metallic |
Material | Plastic |
Max Current | 0.37 A |
Nominal Voltage | 230 V |
Operating Temperature | 14-131 °F |
Operating Temperature | -10-55 °C |
Size | 12.8 x 12.82 x 6.36 in |
Type | Fans and Filter Fans |
Voltage AC | 200-250 V |
Voltage Rating | 230 VAC |
Weight | 11.25 lb |
Weight | 1.9 kg |
Width | 326 mm |
Width | 12.82 in |
Package Dimensions (L x W x H) | 14.75 IN x 14.75 IN x 9.63 IN |
Package Dimensions (L x W x H) | 37.465 cm x 37.465 cm x 24.4602 cm |
Package Weight (Imperial) | 11.250 L |
Package Weight (Metric) | 5.103 kg |
How to Install the Side-Mount Filter Fans and Grilles
This guide provides step-by-step instructions for installing side-mount filter fans and grilles in an enclosure, ensuring proper fit and functionality.
Estimated time: 45m
Tools needed:
Screwdriver, Drill, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors, Cutout template
- Prepare the enclosure
Apply the cutout template to the desired location on the side of the enclosure. Ensure it is aligned correctly before proceeding.
- Cut the opening
Using an appropriate cutting tool, cut out the hole in the enclosure as per the template specifications. Deburr the cutting edge to prevent injury.
- Insert the fan or grille
Insert the fan or grille into the cutout opening and push until all four corners snap and lock into place.
- Secure the installation
If the enclosure material thickness is between 0.10 (2.5 mm) and 0.14 (3.5 mm), install mounting fasteners. For thickness greater than 0.14 (3.5 mm), ensure fasteners are used to maintain the IP/Type 12 rating.
- Wire the filter fan
Follow the wiring diagrams provided in the manual to connect the filter fan to the power supply. Ensure all connections are secure.
- Verify clearance
Ensure that the installed filter fan has a minimum clearance of 7.00 (178 mm) from any obstructions to allow for proper airflow.
- Test the installation
Power on the system and verify that the fan operates correctly. Use a multimeter to check voltage and ensure proper functionality.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.