Overview

The nVent F66LTA Tee Fitting (SKU: F66LTA) is a 6.00 x 6.00 inch (152 x 152 mm) steel wireway fitting designed for efficient branching of wireway runs in industrial and commercial applications. Constructed from durable steel with a corrosion-resistant gray finish, this tee fitting features a lay-in hinged cover with a top opening, enabling simultaneous access to all three branches for streamlined cable installation, modification, or troubleshooting. Certified by the Canadian Standards Association, the F66LTA is ideal for applications requiring organized power and control wiring, including industrial automation, data centers, commercial buildings, and manufacturing plants. Its top-opening design eliminates the need for complete disassembly during maintenance, reducing downtime and labor costs. Each fitting includes two flat sealing plates with gaskets and screws for secure section joining. Compatible with NEMA Type 12 wireway systems, the F66LTA ensures reliable performance in demanding environments.
  • Lay-in Hinged Cover Tee Fitting with Top Opening is used when the covers of all three branches of the wireway run are open along the same side
  • Tee Fittings are finished with paint over plated surfaces
  • Durable steel construction with corrosion-resistant gray finish
  • Includes 2 flat sealing plates with gaskets and screws for secure joining
  • CSA certified for NEMA Type 12 wireway systems

Specifications

Application
Power Distribution
Color
Gray
Color Code
ANSI 61
Finish
Galvanized;Painted
Finish
Galvanized
Height
44 IN
Height
6
Height
152
IP Rating
IP54
Material
Mild Steel
Material
Steel
Material
Mild Steel;Steel
Modification Services
Yes
NEMA Rating
12 Indoor, dust-resistant
NEMA Rating
12
Protection Rating
NEMA Type 12
Sealing Plate Quantity
2
Sealing Plate Type
Flat
Series
nVent
Size
6.00x6.00
Thickness
1.9 mm
Thickness
14 ga
Thickness
51.40mm (2.024")
Type
Tee
Type
Industrial Lay-in Wireway;Tee
Type Number
Type 12
Weight
11.2 lb
Width
6
Width
152
Width
23 IN
Wireway
Lay-In NEMA Type 12 Wireway
Package Dimensions (L x W x H)
12.7 IN x 10.7 IN x 8.2 IN
Package Dimensions (L x W x H)
32.258 cm x 27.178 cm x 20.828 cm
Package Weight (Imperial)
11.200 L
Package Weight (Metric)
5.080 kg
Cutoff Fitting Lay-in, 6.00x6.00, Gray, Steel

F66LXL

Cutoff Fitting Lay-in, 6.00x6.00, Gray, Steel
N12 Wireway, Cut-Off Fitting, Lay-In - Fits 12 x 6 - Steel/Gray

1485FW1

N12 Wireway, Cut-Off Fitting, Lay-In - Fits 12 x 6 - Steel/Gray
Wire Safe Fitting - 6 inch X 6 Inch External Coupling.

EGCER

Wire Safe Fitting - 6 inch X 6 Inch External Coupling.
Twin-70 raceway base, 10 foot length. Supplied with pre-punched mounting holes. 2' of cover needed for every 1' of Twin-70 base.

T702BIW10

Twin-70 raceway base, 10 foot length. Supplied with pre-punched mounting holes. 2' of cover needed for every 1' of Twin-70 base.

How to Install the F66LTA Wireway

This guide provides step-by-step instructions for installing and configuring the F66LTA wireway system, ensuring proper assembly and sealing for optimal performance.

Estimated time: 1h

Tools needed:

Screwdriver, Drill, Wrench

Supplies needed:

Mounting screws, Gaskets, Seal plates, Wire connectors

  1. Assemble wireway sections

    Place a gasket between the flanges of the wireway sections and secure them using screws and nuts as shown in the installation details.

  2. Seal joints

    After installing the wires, seal each joint between sections using either the LSGQR fitting method or the 90° sealing plate method, ensuring that gaskets are visible and properly positioned.

  3. Install box entries

    Make a cutout in the control enclosure for the wireway entry, position the box connector and gasket inside, and install a 90° sealing plate to secure the connection.

  4. Adjust telescope fitting

    Assemble the compression ring, gasket, and retainer on the telescope fitting, insert it into the straight section, and adjust to the desired length before securing with screws.

  5. Anchor telescope fitting

    If the telescope fitting is used vertically, drill .25 inch diameter holes through the fitting and straight section, then install screws and cap nuts to secure it in place.

  6. Calibrate wireway

    Ensure that all sections are level and properly aligned, and verify that all connections are secure using a multimeter to check for continuity.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.