- Divides wireway into two or three compartments
- Plated spring steel brackets hold barriers in place by friction fit inside wireway
- Order barrier and bracket separately. Recommended spacing increments of 3 feet
- Facilitates cable organization and simplifies maintenance
- Easy installation with plated spring steel friction-fit brackets
Specifications
Application | Power Distribution |
Color | Gray |
Color Code | ANSI 61 |
Depth | 120 in |
Depth | 3,048 mm |
Depth | 13 IN |
Finish | Galvanized;Painted |
Finish | Galvanized |
Height | 44 IN |
Height | 6 |
Height | 152 |
Material | Mild Steel |
Material | Steel |
Material | Mild Steel;Steel |
Modification Services | Yes |
Mounting Type | Bracket Mounted |
NEMA Rating | 12 Indoor, dust-resistant |
NEMA Rating | 12 |
Protection Rating | NEMA Type 12 |
Size | 6.00x6.00 |
Thickness | 14 ga |
Thickness | 51.40mm (2.024") |
Thickness | 1.9 mm |
Type | Barrier Kit |
Type | Barrier Kit;Industrial Lay-in Wireway |
Weight | 30.78 lb |
Width | 23 IN |
Width | 6 |
Width | 152 |
Wireway | Lay-In NEMA Type 12 Wireway |
Package Dimensions (L x W x H) | 63.75 IN x 6.25 IN x 5.5 IN |
Package Dimensions (L x W x H) | 161.925 cm x 15.875 cm x 13.97 cm |
Package Weight (Imperial) | 31.000 L |
Package Weight (Metric) | 14.062 kg |

T702BIW10
Twin-70 raceway base, 10 foot length. Supplied with pre-punched mounting holes. 2' of cover needed for every 1' of Twin-70 base.How to Install the Lay-In Wireway
This guide provides step-by-step instructions for installing and sealing a Lay-In Wireway for effective cable management.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Gaskets, Terminal connectors
- Assemble the wireway sections
Place a gasket between the flanges of the wireway sections and secure them using screws and nuts as shown in the installation details.
- Seal the joints
After installing the wires, seal each joint between the sections using either the LSGQR fitting method or the 90° angle sealing plate method as described in the installation instructions.
- Install box entries
Make a cutout in the control enclosure for the wireway entry, position the box connector and gasket inside, and install a 90° angle sealing plate to secure the connection.
- Adjust telescope fitting
Assemble the compression ring, gasket, and retainer on the telescope fitting, insert it into the straight section, and adjust to the desired length before securing with screws.
- Anchor telescope fitting
If the telescope fitting is used vertically, drill .25 inch diameter holes through the sides and bottom of the straight section and telescope fitting, then install screws with cap nuts and lockwashers.
- Calibrate and test
After installation, verify all connections with a multimeter to ensure proper grounding and continuity across the wireway.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.