Optimize your wireway system with the nVent F66B560 Steel Barrier Kit. Designed for 6.00x6.00 inch wireways, this gray steel kit effectively divides a single conduit into two or three distinct compartments. This separation is critical for preventing electromagnetic interference (EMI) between power and data cables, ensuring signal integrity and system reliability. The compartmentalization also aids in thermal management by improving airflow and simplifies maintenance by organizing cable pathways. Installation is straightforward, utilizing plated spring steel brackets that secure the barriers via a friction fit, eliminating the need for specialized tools. nVent recommends spacing barriers at 3-foot increments for optimal performance. The barrier and its supporting brackets are ordered separately, offering flexibility for custom configurations. Key benefits include enhanced cable protection against cross-talk, improved organization, simplified maintenance, durable steel construction, and easy friction-fit installation. The nVent F66B560 is an essential component for industrial, commercial, and data center applications requiring structured and protected electrical infrastructure. SKU: F66B560.
  • Divides wireway into two or three compartments
  • Plated spring steel brackets hold barriers in place by friction fit inside wireway
  • Order barrier and bracket separately. Recommended spacing increments of 3 feet
  • Facilitates cable organization and simplifies maintenance
  • Easy installation with plated spring steel friction-fit brackets

Specifications

Application
Power Distribution
Color
Gray
Color Code
ANSI 61
Depth
120 in
Depth
3,048 mm
Depth
13 IN
Finish
Galvanized;Painted
Finish
Galvanized
Height
44 IN
Height
6
Height
152
Material
Mild Steel
Material
Steel
Material
Mild Steel;Steel
Modification Services
Yes
Mounting Type
Bracket Mounted
NEMA Rating
12 Indoor, dust-resistant
NEMA Rating
12
Protection Rating
NEMA Type 12
Size
6.00x6.00
Thickness
14 ga
Thickness
51.40mm (2.024")
Thickness
1.9 mm
Type
Barrier Kit
Type
Barrier Kit;Industrial Lay-in Wireway
Weight
30.78 lb
Width
23 IN
Width
6
Width
152
Wireway
Lay-In NEMA Type 12 Wireway
Package Dimensions (L x W x H)
63.75 IN x 6.25 IN x 5.5 IN
Package Dimensions (L x W x H)
161.925 cm x 15.875 cm x 13.97 cm
Package Weight (Imperial)
31.000 L
Package Weight (Metric)
14.062 kg
Straight Section Lay-in Hinged Cover Type 12, 6.00x6.00x120.00, Gray, Steel

F66L120

Straight Section Lay-in Hinged Cover Type 12, 6.00x6.00x120.00, Gray, Steel
N12 Wireway, Bracket Hanger - Fits 4 x 4 - Steel/Gray

1485CL2

N12 Wireway, Bracket Hanger - Fits 4 x 4 - Steel/Gray
Wire Safe Fitting - 6 inch X 6 Inch External Coupling.

EGCER

Wire Safe Fitting - 6 inch X 6 Inch External Coupling.
Twin-70 raceway base, 10 foot length. Supplied with pre-punched mounting holes. 2' of cover needed for every 1' of Twin-70 base.

T702BIW10

Twin-70 raceway base, 10 foot length. Supplied with pre-punched mounting holes. 2' of cover needed for every 1' of Twin-70 base.

How to Install the Lay-In Wireway

This guide provides step-by-step instructions for installing and sealing a Lay-In Wireway for effective cable management.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Gaskets, Terminal connectors

  1. Assemble the wireway sections

    Place a gasket between the flanges of the wireway sections and secure them using screws and nuts as shown in the installation details.

  2. Seal the joints

    After installing the wires, seal each joint between the sections using either the LSGQR fitting method or the 90° angle sealing plate method as described in the installation instructions.

  3. Install box entries

    Make a cutout in the control enclosure for the wireway entry, position the box connector and gasket inside, and install a 90° angle sealing plate to secure the connection.

  4. Adjust telescope fitting

    Assemble the compression ring, gasket, and retainer on the telescope fitting, insert it into the straight section, and adjust to the desired length before securing with screws.

  5. Anchor telescope fitting

    If the telescope fitting is used vertically, drill .25 inch diameter holes through the sides and bottom of the straight section and telescope fitting, then install screws with cap nuts and lockwashers.

  6. Calibrate and test

    After installation, verify all connections with a multimeter to ensure proper grounding and continuity across the wireway.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.