nVent F44WT - Tee Feed-Through, 4.00x4.00, Gray, Steel
nVent

F44WT

UPC: 783510143008


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent F44WT is a 4.00 x 4.00 inch steel feed-through tee fitting for wireway systems. It provides a T-type branch connection for routing cables in industrial settings. Constructed from gray steel, this fitting measures 4.00x4.00 inches (102x102 mm) with a height of 7.00 inches (178 mm). It is IP12 rated for dust protection and meets NEMA Type 12 standards, making it suitable for indoor use in dusty or washdown environments. Designed for compatibility with nVent wireway sections, it ensures organized cable pathways in manufacturing plants, food processing facilities, and data centers. Manufactured by nVent.
  • Feed-Through Tees are used for making T-type turns in wireway runs
  • Connects to other wireway sections and fittings and protects wires and cables against dust in a broad range of industrial applications
  • Gray steel construction
  • IP12 rated for dust protection
  • NEMA Type 12 compliant for indoor industrial use

Specifications

Application
Power Distribution
Color
Gray
Color Code
ANSI 61
Finish
Painted;Powder Coat
Finish
Powder Coated
Height
44 IN
Height
4
Height
102
IP Rating
IP54
Material
Mild Steel
Material
Mild Steel;Steel
Modification Services
Yes
NEMA Rating
12 Indoor, dust-resistant
NEMA Rating
12
Protection Rating
NEMA Type 12
Thickness
14 ga
Thickness
1.9 mm
Thickness
51.40mm (2.024")
Type
Industrial Feed-Through Wireway;Tee
Type
Tee
Type Number
Type 12
Weight
5.8 lb
Width
23 IN
Width
4
Width
102
Wireway
Feed-Through NEMA Type 12 Wireway
Package Dimensions (L x W x H)
8.3 IN x 5.7 IN x 10.9 IN
Package Dimensions (L x W x H)
21.082 cm x 14.478 cm x 27.686 cm
Package Weight (Imperial)
5.800 L
Package Weight (Metric)
2.631 kg
Straight Section Feed-Through Type 12, 4.00x4.00x12.00, Gray, Steel

F44W12

Straight Section Feed-Through Type 12, 4.00x4.00x12.00, Gray, Steel
N12 Wireway, Cut-Off Fitting, Lay-In - Fits 12 x 6 - Steel/Gray

1485FW1

N12 Wireway, Cut-Off Fitting, Lay-In - Fits 12 x 6 - Steel/Gray
Wire Safe Fitting - 4 inch X 4 Inch External Coupling.

EGCEN

Wire Safe Fitting - 4 inch X 4 Inch External Coupling.
The LDPH10 power rated Surface Raceway is a two-piece latching raceway with cover suitable for applications up to 600 V. It features pre-punched mounting holes and factory-applied adhesive backing for fast mounting. It is 6 feet in length and is 1.52 inches wide by 0.86 inches deep. It meets TIA/EIA Standards, is UL5A Listed, and is UL Compliant. It is International Gray.

LDPH10IG6-A

The LDPH10 power rated Surface Raceway is a two-piece latching raceway with cover suitable for applications up to 600 V. It features pre-punched mounting holes and factory-applied adhesive backing for fast mounting. It is 6 feet in length and is 1.52 inches wide by 0.86 inches deep. It meets TIA/EIA Standards, is UL5A Listed, and is UL Compliant. It is International Gray.

How to Install the Feed-Through Wireway

This guide provides step-by-step instructions for installing and configuring the Feed-Through Wireway, ensuring proper assembly and connection.

Estimated time: 1h

Tools needed:

Screwdriver, Drill, Wire strippers

Supplies needed:

Mounting screws, Gaskets, Nuts, Lockwashers

  1. Assemble the wireway sections

    Place a gasket between the flanges of the wireway sections and secure them using screws and nuts as shown in the assembly details.

  2. Install the telescope fitting

    Assemble the telescope fitting parts in the correct order, insert it into the straight section, and adjust to the desired length. Ensure the gasket is properly positioned against the flange.

  3. Anchor the telescope fitting

    Drill .25 inch diameter holes through the straight section and telescope fitting. Install .25−20x.5 screws from the outside and secure with cap nuts and lockwashers.

  4. Cut the wireway to length

    Cut the wireway body to the desired length, ensuring a square cut. Weld an extra flange to the body and grind off any sharp edges.

  5. Install the swivel nipple

    Position the wireway section, flange gasket, swivel ring, and swivel nipple in order. Secure with clips, screws, and nuts as specified in the installation details.

  6. Make box entries

    Cut out the necessary openings in the enclosure for box entries. Position the box connector and gasket inside the enclosure, ensuring proper alignment with the wireway.

  7. Install hangers

    Assemble and attach the hangers to the wireway flanges in the desired positions, ensuring they do not fit between adjacent wireway flanges.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.