Authorized nVent Distributor
nVent F44T136GV - Straight Section Layin Flat Cover Type 1 no KOs, 4x4x36, Galvanized, Steel

nVent F44T136GV Straight Section Layin Flat Cover Type 1 no KOs, 4x4x36, Galvanized, Steel

UPC: 783510881603


Documents & Media
Installation InstructionsVideo Clip

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent **F44T136GV Straight Section Lay-in Flat Cover Type 1** is a premium galvanized steel wireway component designed for efficient and damage-free cable management in industrial, commercial, and institutional environments. Engineered for durability and ease of installation, this 4x4x36-inch straight section features a fully open side for simplified wire and cable lay-in, eliminating the need for labor-intensive pulling-through methods that risk insulation damage. The flat cover design enables flush mounting against walls or ceilings, ensuring a clean, professional appearance while maintaining full access to the wireway interior via keyhole screw slots for quick inspections or modifications. Constructed from high-quality galvanized steel, this Type 1 wireway section delivers superior corrosion resistance, making it ideal for both indoor and outdoor applications where exposure to moisture, chemicals, or harsh environmental conditions is a concern. The absence of knockouts (KOs) provides a smooth interior surface, reducing snag points and facilitating smoother cable routing. Available in lengths ranging from 12 to 120 inches, the F44T136GV is part of nVent’s comprehensive wireway system, offering flexibility to accommodate projects of any scale—from small office renovations to large-scale industrial installations. **Key Applications & Industries:** This wireway section is particularly well-suited for: - **Industrial Facilities:** Manufacturing plants, refineries, and processing facilities where robust cable protection is critical for operational safety and compliance with NEC/OSHA standards. - **Commercial Buildings:** Office complexes, retail spaces, and data centers requiring organized, code-compliant cable management for power distribution, lighting, and IT infrastructure. - **Institutional Settings:** Schools, hospitals, and government buildings where long-term durability and ease of maintenance are priorities. - **Outdoor Installations:** Parking structures, utility corridors, and perimeter lighting systems exposed to weather elements. **Installation & Compatibility Benefits:** The lay-in design of the F44T136GV streamlines the wiring process by allowing cables to be placed directly into the channel, reducing labor time and minimizing the risk of jacket or insulation damage—a common issue with traditional pull-through wiring methods. The flat cover’s keyhole slots enable tool-free access for future adjustments, while the galvanized finish ensures longevity in demanding environments. Compatible with nVent’s full line of Type 1 wireway accessories, including elbows, tees, and fittings, this section integrates seamlessly into larger cable management systems. **Why Choose nVent?** As a global leader in electrical and thermal management solutions, nVent delivers products engineered for performance, safety, and reliability. The F44T136GV reflects the company’s commitment to innovation, with features that address real-world challenges in cable management—such as corrosion resistance, modularity, and compliance with industry standards like UL and NEMA Type 1. Backed by decades of expertise, nVent’s wireway systems are trusted by professionals who demand precision and durability in their installations. For projects where cable integrity and long-term protection are non-negotiable, the F44T136GV stands as a cost-effective, high-performance solution.
  • Lay-in Flat-Cover Type 1 Straight Sections are used for enclosing wire and cable in wireway runs
  • Sections are completely open on one side so wires and cables can be laid-in along run
  • Lay-in design eliminates the action of pulling wires or cables, which can result in insulation damage
  • Flat-cover design supports mounting flush with walls or ceilings
  • Covers feature keyhole screw slots which simplify cover installation and removal, and limit risk of losing securing screws
  • Sections available in lengths from 12 to 120 inches, with or without knockouts
  • 4"x4" and 6"x6" Straight Sections re-designed with Snap Connect features for ease-of-installation; sections are backwards compatible if a legacy U-Connector is present

Specifications

Application
Power Distribution
Color
Unpainted
Connection Type
Snap-in
Depth
914 mm
Depth
36 in
Depth
13 IN
Finish
Galvanized
Height
44 IN
Height
4 in
Height
101.6 mm
Height
102
Knockouts
False
Knockouts
No
Material
Mild Steel;Steel
Material
Mild Steel
Material
Galvanized Steel
Modification Services
No
NEMA Rating
1 Indoor, electrical protection
NEMA Rating
Type 1
NEMA Rating
1
Protection Rating
NEMA Type 1
Size
4x4x36 inches
Thickness
1.52 mm
Thickness
16 ga
Thickness
51.40mm (2.024")
Type
Straight Section
Type
Commercial Lay-in Galvanized Flat-Cover Type 1 Wireway;Straight Section
Type Number
Type 1
Weight
10 lb
Width
23 IN
Width
102
Width
4 IN
Wireway
Lay-In NEMA Type 1 Galvanized Wireway
Package Dimensions (L x W x H)
37 IN x 4.25 IN x 4.25 IN
Package Dimensions (L x W x H)
93.98 cm x 10.795 cm x 10.795 cm
Package Weight (Imperial)
10.000 L
Package Weight (Metric)
4.536 kg
Straight Section Layin Flat Cover Type 1 KOs, 4x4x36, Galvanized, Steel

F44T136GVWK

Straight Section Layin Flat Cover Type 1 KOs, 4x4x36, Galvanized, Steel
Type 3R Wiring Trough - 6x6x12 - Galv/Gray

C3RWT612

Type 3R Wiring Trough - 6x6x12 - Galv/Gray
Wire Safe Fitting - 4 inch X 4 Inch External Coupling.

EGCEN

Wire Safe Fitting - 4 inch X 4 Inch External Coupling.
The T-70 raceway Base provides solutions for routing low voltage, fiber optic, and/or power cabling along perimeter walls. The T-70 raceway is supplied with pre-punched mounting holes and is tamper resistant. It is 8 ft and Electric Ivory.

T70BEI8

The T-70 raceway Base provides solutions for routing low voltage, fiber optic, and/or power cabling along perimeter walls. The T-70 raceway is supplied with pre-punched mounting holes and is tamper resistant. It is 8 ft and Electric Ivory.
WW, Type 1, Adapter to Comp, Bulletin F40G (Galvanized Type 1 & 3R Wireway - Galvanized Type 1 Lay-In Wireway 6x6), Size/Dims: 6.00x6.00, Material: Steel, Finish:

F66GASGV

WW, Type 1, Adapter to Comp, Bulletin F40G (Galvanized Type 1 & 3R Wireway - Galvanized Type 1 Lay-In Wireway 6x6), Size/Dims: 6.00x6.00, Material: Steel, Finish:
Straight Section Layin Flat Cover Type 1 KOs, 2.5x2.5x24, Galvanized, Steel

F22T124GVWK

Straight Section Layin Flat Cover Type 1 KOs, 2.5x2.5x24, Galvanized, Steel
Straight Section Layin Flat Cover Type 1 KOs, 4x4x24, Galvanized, Steel

F44T124GVWK

Straight Section Layin Flat Cover Type 1 KOs, 4x4x24, Galvanized, Steel
Straight Section Layin Flat Cover Type 1 no KOs, 8x8x12, Galvanized, Steel

F88T112GV

Straight Section Layin Flat Cover Type 1 no KOs, 8x8x12, Galvanized, Steel

How to Install nVent HOFFMAN Type 1 Snap Connect Wireway

This guide provides step-by-step instructions for connecting and securing sections of the nVent HOFFMAN Type 1 Snap Connect Wireway using its snap feature and fasteners.

Estimated time: 15m

Tools needed:

Screwdriver, Torque wrench (recommended)

Supplies needed:

Hex head screws (10-32x.250), Hex nuts (10-32), Lock washers (#10)

  1. Connect Wireway Sections

    Align two sections of the Type 1 Snap Connect Wireway. Push them together firmly until they audibly 'Click' into place, ensuring a secure initial connection.

  2. Install First Securing Screw

    Insert a 10-32x.250 hex head screw through the designated hole on the connected wireway sections. Secure it from the other side with a 10-32 hex nut and a #10 lock washer.

  3. Tighten First Securing Screw

    Using a screwdriver or torque wrench, tighten the first screw to a torque of 4.5 0.5 N*M [40 4.0 LBF*IN]. Ensure the connection is firm but do not overtighten.

  4. Install Second Securing Screw

    Insert a second 10-32x.250 hex head screw through the remaining designated hole on the connected wireway sections. Secure it from the other side with a 10-32 hex nut and a #10 lock washer.

  5. Tighten Second Securing Screw

    Using a screwdriver or torque wrench, tighten the second screw to a torque of 4.5 0.5 N*M [40 4.0 LBF*IN]. Verify both screws are securely fastened to complete the connection.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.