Overview

The nVent F44T124GVWK Straight Section Lay-in Flat Cover Type 1 is a premium galvanized steel wireway component engineered for durable, efficient cable management in commercial, industrial, and institutional applications. Designed with a 4x4x24-inch profile, this straight section features knockouts (KOs) for seamless integration with other wireway components, ensuring a clean, organized installation. The fully open side design eliminates the need for wire pulling, significantly reducing the risk of insulation damage—a common issue in traditional pull-through wiring systems. This not only streamlines installation but also enhances long-term reliability by preserving cable integrity. This wireway section is ideal for enclosing and protecting electrical wiring in exposed or concealed runs, including walls, ceilings, and utility corridors. The flat cover design allows for flush mounting, providing a sleek, professional appearance while maintaining accessibility via keyhole screw slots for easy maintenance and future modifications. Constructed from high-quality galvanized steel, the F44T124GVWK delivers superior corrosion resistance, making it suitable for both indoor and outdoor environments where durability is critical. Professionals across industries such as manufacturing, data centers, healthcare, and commercial construction rely on nVent wireway systems for their robust construction and compliance with electrical safety standards. The Type 1 rating ensures compatibility with a wide range of electrical codes, including NEC requirements for wireway installations. Available in multiple lengths (12 to 120 inches) and configurations (with or without knockouts), this product offers flexibility to accommodate diverse project requirements. nVent, a global leader in electrical and thermal management solutions, is trusted for its commitment to innovation and quality. The F44T124GVWK reflects the brand’s dedication to providing high-performance products that enhance safety, efficiency, and longevity in electrical installations. Whether used in new construction or retrofit projects, this wireway section delivers unmatched performance and peace of mind for electrical contractors, engineers, and facility managers alike.
  • Lay-in Flat-Cover Type 1 Straight Sections are used for enclosing wire and cable in wireway runs
  • Sections are completely open on one side so wires and cables can be laid in along wireway run
  • No pulling through of wires or cables prevents damage to insulation that often occurs in a pull-through wiring system
  • Flat cover design allows for mounting flush with walls or ceilings
  • Keyhole screw slots on flat covers provide easy access. Galvanized material provides superior corrosion protection for outdoor applications
  • Sections are available in lengths from 12 inch to 120 inch, with or without knockouts.

Specifications

Application
Power Distribution
Color
Unpainted
Depth
13 IN
Depth
610 mm
Depth
24 in
Finish
Galvanized
Height
44 IN
Height
4
Height
102
Knockout Quantity, 0.50 - 0.75 in
8
Knockout Quantity, 1.00 - 1.25 in
8
Knockout Sizes
(8) 1.0 - 1.25"
Knockouts
Yes
Knockouts
True
Material
Mild Steel;Steel
Material
Mild Steel
Modification Services
No
NEMA Rating
1 Indoor, electrical protection
NEMA Rating
1
Protection Rating
NEMA Type 1
Thickness
1.52 mm
Thickness
16 ga
Thickness
51.40mm (2.024")
Type
Straight Section
Type
Commercial Lay-in Galvanized Flat-Cover Type 1 Wireway;Straight Section
Type Number
Type 1
Weight
6.7 lb
Width
23 IN
Width
4
Width
102
Wireway
Lay-In NEMA Type 1 Galvanized Wireway
Package Dimensions (L x W x H)
24 IN x 4.2 IN x 4.1 IN
Package Dimensions (L x W x H)
60.96 cm x 10.668 cm x 10.414 cm
Package Weight (Imperial)
6.700 L
Package Weight (Metric)
3.039 kg
Straight Section Layin Flat Cover Type 1 no KOs, 4x4x24, Galvanized, Steel

F44T124GV

Straight Section Layin Flat Cover Type 1 no KOs, 4x4x24, Galvanized, Steel
Type 3R Wiring Trough - 6x6x12 - Galv/Gray

C3RWT612

Type 3R Wiring Trough - 6x6x12 - Galv/Gray
Wire Safe Fitting - 4 inch X 4 Inch External Coupling.

EGCEN

Wire Safe Fitting - 4 inch X 4 Inch External Coupling.
The T-70 raceway Base provides solutions for routing low voltage, fiber optic, and/or power cabling along perimeter walls. The T-70 raceway is supplied with pre-punched mounting holes and is tamper resistant. It is 8 ft and Electric Ivory.

T70BEI8

The T-70 raceway Base provides solutions for routing low voltage, fiber optic, and/or power cabling along perimeter walls. The T-70 raceway is supplied with pre-punched mounting holes and is tamper resistant. It is 8 ft and Electric Ivory.

How to Install nVent HOFFMAN Type 1 Snap Connect Wireway

This guide provides step-by-step instructions for connecting and securing sections of the nVent HOFFMAN Type 1 Snap Connect Wireway using its snap feature and fasteners.

Estimated time: 15m

Tools needed:

Screwdriver, Torque wrench (recommended)

Supplies needed:

Hex head screws (10-32x.250), Hex nuts (10-32), Lock washers (#10)

  1. Connect Wireway Sections

    Align two sections of the Type 1 Snap Connect Wireway. Push them together firmly until they audibly 'Click' into place, ensuring a secure initial connection.

  2. Install First Securing Screw

    Insert a 10-32x.250 hex head screw through the designated hole on the connected wireway sections. Secure it from the other side with a 10-32 hex nut and a #10 lock washer.

  3. Tighten First Securing Screw

    Using a screwdriver or torque wrench, tighten the first screw to a torque of 4.5 0.5 N*M [40 4.0 LBF*IN]. Ensure the connection is firm but do not overtighten.

  4. Install Second Securing Screw

    Insert a second 10-32x.250 hex head screw through the remaining designated hole on the connected wireway sections. Secure it from the other side with a 10-32 hex nut and a #10 lock washer.

  5. Tighten Second Securing Screw

    Using a screwdriver or torque wrench, tighten the second screw to a torque of 4.5 0.5 N*M [40 4.0 LBF*IN]. Verify both screws are securely fastened to complete the connection.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.