The nVent F22LXL is a 2.50 x 2.50 inch (64 x 64 mm) gray steel cutoff fitting designed for industrial conduit systems. This lay-in type fitting features a hinged cover for easy access. Manufactured by nVent, it allows for on-site modification by shortening the body to a desired length between 9.00 and 15.00 inches (229-381 mm) and welding the cover. It is suitable for commercial, industrial, and utility applications where conduit runs require customization and accessibility for wire pulling and maintenance.
  • Lay-In Hinged Cover Cutoff Fittings are used for lengths of 9.00 inch (229 mm) to 15.00 inch (381 mm)
  • Body comes in two pieces. Shorten body and cover to the desired length and weld together
  • Fittings are finished with paint over plated surfaces
  • Hinged cover for convenient maintenance
  • On-site modification capability (shorten body and weld cover)

Specifications

Application
Power Distribution
Color
Gray
Color Code
ANSI 61
Finish
Galvanized
Height
44 IN
Height
2.5
Height
64
IP Rating
IP54
Material
Mild Steel
Material
Steel
Modification Services
Yes
NEMA Rating
12 Indoor, dust-resistant
NEMA Rating
12
Protection Rating
NEMA Type 12
Sealing Plate Quantity
1
Sealing Plate Type
Flat
Size
2.50x2.50 in (63.5x63.5 mm)
Thickness
51.40mm (2.024")
Thickness
1.9 mm
Thickness
14 ga
Type
Cut-Off Fitting
Type
Cut-Off Fitting;Industrial Lay-in Wireway
Weight
5.2 lb
Width
23 IN
Width
2.5
Width
64
Wireway
Lay-In NEMA Type 12 Wireway
Package Dimensions (L x W x H)
16.4 IN x 4.2 IN x 4.4 IN
Package Dimensions (L x W x H)
41.656 cm x 10.668 cm x 11.176 cm
Package Weight (Imperial)
5.200 L
Package Weight (Metric)
2.359 kg
Tee Fitting Lay-in Hinged Cover Outside Top Opening, 2.50x2.50, Gray, Steel

F22LTC

Tee Fitting Lay-in Hinged Cover Outside Top Opening, 2.50x2.50, Gray, Steel
N12 Wireway, Cut-Off Fitting, Lay-In - Fits 12 x 6 - Steel/Gray

1485FW1

N12 Wireway, Cut-Off Fitting, Lay-In - Fits 12 x 6 - Steel/Gray
Wire Safe Fitting - 3 inch X 3 Inch Internal Coupling.

EGCIL

Wire Safe Fitting - 3 inch X 3 Inch Internal Coupling.
The LDPH10 power rated Surface Raceway is a two-piece latching raceway with cover suitable for applications up to 600 V. It features pre-punched mounting holes and factory-applied adhesive backing for fast mounting. It is 6 feet in length and is 1.52 inches wide by 0.86 inches deep. It meets TIA/EIA Standards, is UL5A Listed, and is UL Compliant. It is International Gray.

LDPH10IG6-A

The LDPH10 power rated Surface Raceway is a two-piece latching raceway with cover suitable for applications up to 600 V. It features pre-punched mounting holes and factory-applied adhesive backing for fast mounting. It is 6 feet in length and is 1.52 inches wide by 0.86 inches deep. It meets TIA/EIA Standards, is UL5A Listed, and is UL Compliant. It is International Gray.

How to Install the Lay-In Wireway

This guide provides step-by-step instructions for installing and sealing the Lay-In Wireway sections and fittings.

Estimated time: 1h

Tools needed:

Screwdriver, Drill, Wrench

Supplies needed:

Mounting screws, Gaskets, Nuts, Sealing plates

  1. Assemble the wireway sections

    Place a gasket between the flanges of the wireway sections and secure them with screws and nuts as shown in the assembly details.

  2. Seal the joints

    After installing the wires, seal each joint between the sections using either the LSGQR fitting or the 90° sealing plate method as described in the installation instructions.

  3. Install box entries

    Make a cutout in the control enclosure for the box connector, position the gasket inside the enclosure, and install the sealing plate as per the instructions.

  4. Adjust telescope fitting

    Assemble the compression ring, gasket, and retainer on the telescope fitting, insert it into the straight section, and adjust to the desired length.

  5. Anchor telescope fitting

    If the telescope fitting is used vertically, drill .25 inch diameter holes through the sides and bottom of the straight section and telescope fitting, then install screws and cap nuts.

  6. Calibrate the wireway

    Ensure that the wireway is level and securely mounted, making adjustments as necessary to maintain proper alignment.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.