Contact for Pricing
Overview
- Hangers are used to support a wireway run
- The drop hanger is normally attached to an overhead beam or ceiling while the bracket hanger can be used for wall, floor or ceiling installations
- Hangers are finished with paint over plated surfaces
- Suitable for wall, floor, or ceiling mounting
- Manufactured in the USA
Specifications
Application | Power Distribution |
Color | Gray |
Color Code | ANSI 61 |
Finish | Galvanized;Painted |
Finish | Galvanized |
Height | 44 IN |
Height | 2.5 |
Height | 64 |
IP Rating | IP54 |
Material | Mild Steel |
Material | Steel |
Material | Mild Steel;Steel |
Modification Services | Yes |
Mounting Type | Wall, Floor, or Ceiling |
Mounting Type | Wall, Floor, Ceiling |
NEMA Rating | 12 Indoor, dust-resistant |
NEMA Rating | 12 |
Protection Rating | NEMA Type 12 |
Series | nVent F22HB |
Size | 2.50x2.50 |
Size | 2.50x2.50 in |
Thickness | 51.40mm (2.024") |
Thickness | 1.9 mm |
Thickness | 14 ga |
Type | Hanger |
Type | Hanger;Industrial Lay-in Wireway |
Weight | 0.86 lb |
Width | 2.5 |
Width | 64 |
Width | 23 IN |
Wireway | Feed-Through NEMA Type 12 Wireway |
Package Dimensions (L x W x H) | 7.8 IN x 6.7 IN x 3.5 IN |
Package Dimensions (L x W x H) | 19.812 cm x 17.018 cm x 8.89 cm |
Package Weight (Imperial) | 0.860 L |
Package Weight (Metric) | 0.390 kg |

T70BEI10
The T-70 raceway Base provides solutions for routing low voltage, fiber optic, and/or power cabling along perimeter walls. The T-70 raceway is supplied with pre-punched mounting holes and is tamper resistant. It is 10 ft and Electric Ivory.How to Install the Lay-In Wireway
This guide provides step-by-step instructions for installing and sealing a Lay-In Wireway for effective cable management.
Estimated time: 1h
Tools needed:
Screwdriver, Drill, Wrench
Supplies needed:
Mounting screws, Gaskets, Nuts, Wire connectors
- Assemble the wireway sections
Place a gasket between the flanges of the wireway sections and secure them using screws and nuts as shown in the installation details.
- Seal the joints
After installing the wires, seal each joint between the sections using either the LSGQR fitting method or the 90° angle sealing plate method as described in the installation details.
- Install box entries
Make a cutout in the control enclosure for the wireway entry. Position the box connector and gasket inside the enclosure, then install a sealing plate as per the installation instructions.
- Adjust and anchor telescope fitting
Assemble the telescope fitting with the compression ring and gasket. Insert it into the straight section and adjust to the desired length. Anchor it securely using screws or threaded rods as necessary.
- Calibrate and test
Once installed, verify all connections and seals. Use a multimeter to check for continuity and ensure proper grounding if applicable.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.