Overview

The nVent DPC1N119820 is a 19-inch rack-mount Switched PDU and Environmental Monitor designed for critical IT infrastructure. This horizontal unit provides 8x NEMA 5-15R outlets, a 20A, 120V load rating, and a 10-ft. power cord with a 5-15P plug. It enables remote control of individual outlets, allowing administrators to reboot or disable equipment to prevent downtime. Beyond power control, the DPC1N119820 offers essential power monitoring, displaying real-time current, volts, power consumption, and kilowatt-hours via its local LCD display and Ethernet connectivity. This data is vital for capacity planning and identifying power issues. Integrated environmental monitoring features two RJ12 ports for optional plug-and-play sensors (sold separately), enabling the monitoring of temperature, humidity, airflow, sound, and light. This proactive environmental management helps prevent equipment failure. Managed via a web browser interface, it supports DHCP, HTML, HTTPS, SNMP, SMTP, and TCP/IP protocols for secure network integration. It is ANSI/UL 60950 and cUL Listed.
  • Local LCD display, includes port for optional remote display
  • Provides environmental monitoring with two RJ12 ports for plug-and-play optional sensors (ordered separately)
  • Ethernet connectivity
  • 19-in. rack-mount horizontal model has 15A, 120V, (8) NEMA 5-15R outlets
  • 10-ft. power cord with 5-15P

Specifications

Application
Datacom and Telecom Equipment;Networking, Storage and Data Center
Color
Jet Black
Color Code
RAL 9005
Depth
13 IN
Depth
216 mm
Depth
8.5 in
Electrical Load Rating
20 A
Finish
Powder Coated
Height
1.72
Height
44
Material
Mild Steel
Material Quality
Mild Steel
Modification Services
Yes
Number Of Receptacles
8
Receptacle Quantity
8
Receptacle Style
5-15R
Socket Quantity
8
Socket Type
NEMA 5-15R
Thickness
1.52 mm
Thickness
16 ga
Thickness
51.40mm (2.024")
Type
Control PDU, 19-in. Rack-Mount
Type
Power Distribution Units
Voltage AC
120 V
Voltage Rating
125V
Weight
10.6 lb
Width
432 mm
Width
23 IN
Width
432
Width
17 in
Package Dimensions (L x W x H)
22.2 IN x 12.9 IN x 2.7 IN
Package Dimensions (L x W x H)
56.388 cm x 32.766 cm x 6.858 cm
Package Weight (Imperial)
10.600 L
Package Weight (Metric)
4.808 kg
RackPower Automatic Transfer Switch, 110V 20A 10 Rec, Black, Steel

NPATS11002

RackPower Automatic Transfer Switch, 110V 20A 10 Rec, Black, Steel
SmartZone G5 Monitored Switched Per Outlet (MSPO Series) Rack PDU, 16 A Single Phase, 100-240V, (8) C13 receptacles, IEC 60309 2P+E 6h 16A plug and measures 1.713"L x 17.461"W x 7.8"D (43.2mm x 444.5mm x 198.1mm). Color: Black

P08G10M

SmartZone G5 Monitored Switched Per Outlet (MSPO Series) Rack PDU, 16 A Single Phase, 100-240V, (8) C13 receptacles, IEC 60309 2P+E 6h 16A plug and measures 1.713"L x 17.461"W x 7.8"D (43.2mm x 444.5mm x 198.1mm). Color: Black
20 AMP P/B, 24" LONG, 8 RECP

1589T24F1

20 AMP P/B, 24" LONG, 8 RECP
Mini-Link Dist Box, 6 Outlet, 10M cable

3400007

Mini-Link Dist Box, 6 Outlet, 10M cable

How to Install the DPC Power Distribution Unit

This guide provides step-by-step instructions for installing and configuring the DPC Power Distribution Unit (PDU) for optimal performance.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the PDU

    Secure the Power Distribution Unit (PDU) in the rack or cabinet using appropriate mounting hardware. Ensure that the unit is level and firmly attached.

  2. Connect the PDU to Power

    Plug the PDU into an appropriately rated and protected branch circuit receptacle. Ensure that the circuit is turned off before making the connection.

  3. Connect to the Network

    Use an Ethernet cable to connect the PDU to your network. Ensure that the ferrite core is placed around the Ethernet cable close to the PDU to comply with FCC requirements.

  4. Configure the IP Address

    Connect your computer to the PDU using a crossover cable. Set your computer's IP address to 192.168.123.1 and subnet mask to 255.255.255.0. Access the PDU via a web browser at http://192.168.123.123 to configure network settings.

  5. Connect External Sensors (Optional)

    If using external sensors, connect them to the PDU. Ensure that the wiring is straight-through and that the sensors are properly recognized by the unit.

  6. Power On Devices

    Plug in the devices to be powered by the PDU. Power on the devices sequentially to avoid high inrush current.

  7. Set Up Alarms and Monitoring

    Access the Control page on the web interface to configure outlet names, power-on delays, and alarm settings based on your operational requirements.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.