Panduit P08G10M - SmartZone G5 Monitored Switched Per Outlet (MSPO Series) Rack PDU, 16 A Single Phase, 100-240V, (8) C13 receptacles, IEC 60309 2P+E 6h 16A plug and measures 1.713"L x 17.461"W x 7.8"D (43.2mm x 444.5mm x 198.1mm). Color: Black
Panduit

P08G10M

UPC: 613056317543


Documents & Media
BrochureTechnical DrawingFull Engineering DrawingInstallation InstructionsUser ManualOwners Manual

Contact for Pricing

Overview

The Panduit SmartZone G5 Monitored Switched Per Outlet (MSPO) Series Rack PDU, SKU P08G10M, offers intelligent power distribution and monitoring for critical IT infrastructure. This 16A, single-phase unit operates across a wide voltage range of 100-240V, ensuring compatibility with diverse power environments. It features eight IEC C13 receptacles, providing ample connectivity for your equipment. The integrated IEC 60309 2P+E 6h 16A plug ensures secure and reliable power input. Designed for 19-inch rack mounting, this PDU measures 1.713"L x 17.461"W x 7.8"D (43.2mm x 444.5mm x 198.1mm), fitting efficiently into standard rack configurations. The black, all-metal housing provides durability. This MSPO series PDU enables remote control over individual outlets, allowing for the neutralization or reboot of problem equipment, thereby minimizing downtime. It provides essential power monitoring data, including current, voltage, power consumption, and kilowatt-hours, accessible for quick analysis. Additionally, the SmartZone G5 supports environmental monitoring through two RJ12 ports for optional plug-and-play sensors (sold separately), allowing for comprehensive data center management. Ethernet connectivity is included for network access, and a local LCD display offers immediate status information, with an option for a remote display port. This PDU is CSA certified (Standards C22.2 No. 21-95 and No. 42-99) and UL recognized (Standard UL1363), meeting stringent safety and performance standards. Manufactured in the US, the Panduit P08G10M is a robust solution for efficient and monitored power distribution in data centers and enterprise environments.
  • 16A Single Phase, 100-240V operating voltage
  • Eight IEC C13 receptacles for equipment power
  • IEC 60309 2P+E 6h 16A plug for secure input
  • Remote per-outlet switching for rebooting/disabling
  • Power monitoring (current, volts, kWh) and environmental monitoring capabilities

Specifications

Amperage Rating
16A
Color
Black
Connection Type
IEC 60309 2P+E 6h 16A
Control
Monitored Switched Per Outlet
Current Rating
16 A
Frequency Rating
100-240V
Frequency Rating, Maximum
230 V
Frequency Rating, Minimum
230 V
Height
1.71 IN
Material
Metal
Mounting
Horizontal
Number Of Receptacles
8
Phase
16
Phase
1
Poles
2P+E
Receptacle
(8) C13
Series
SmartZone G5 Monitored Switched Per Outlet (MSPO Series)
Size
1.713"L x 17.461"W x 7.8"D (43.2mm x 444.5mm x 198.1mm)
Standard
CE, UKCA, ROHS, REACH, China ROHS
Type
PDU
Type
Horizontal Intelligent Power Distribution Unit
Voltage Rating
100-240V
Voltage Rating
100-240 V
Width
17.5 in
Width
444.5 mm
Width
17.46 IN
Package Dimensions (L x W x H)
78 IN x 8.2 IN x 4.6 IN
Package Weight (Imperial)
12.9 lbs
This Panduit G5 Basic PDU features (12) C13 outlets. It is a 16 amp, 230 V, single phase PDU with an IEC 60309 2P+E 6h 16A (IP44) input plug and a 10 foot (3m) power cord. The PDU is black.

P12B34M

This Panduit G5 Basic PDU features (12) C13 outlets. It is a 16 amp, 230 V, single phase PDU with an IEC 60309 2P+E 6h 16A (IP44) input plug and a 10 foot (3m) power cord. The PDU is black.
RackPower Automatic Transfer Switch, 110V 15A 10 Rec, Black, Steel

NPATS11001

RackPower Automatic Transfer Switch, 110V 15A 10 Rec, Black, Steel
6 OUTLETS, LIGHT, 15' TW LCK

1584T6D1

6 OUTLETS, LIGHT, 15' TW LCK
Mini-Link Dist Box, 6 Outlet, 10M cable

3400007

Mini-Link Dist Box, 6 Outlet, 10M cable

How to Install and Configure a Panduit G5 PDU

This guide provides step-by-step instructions for installing Panduit G5 Metered, Switched, and Metered & Switched Power Distribution Units (PDUs) into a datacenter rack, including mounting, grounding, power connection, and initial configuration.

Estimated time: 45m

Tools needed:

Phillips screwdriver, Torx screwdriver

Supplies needed:

Mounting buttons (if applicable), Cage nuts (if applicable), Ground bonding cable, Star washer, Tie wraps

  1. Mount the PDU in the Rack

    Determine the appropriate mounting method for your PDU form factor (vertical 0U, 1U, or 2U). For vertical PDUs, install mounting buttons on the PDU, then insert them into the keyhole slots on the rack's PDU mounting bracket. For 1U or 2U PDUs, install cage nuts at the desired U location, then screw the PDU's mounting bracket ears into the RETMA rail surface. Ensure the PDU is level and firmly secured.

  2. Connect the Ground Bonding Cable

    Locate the external ground bonding point on the PDU chassis. Connect a ground bonding cable from this point to a known earthed reference terminal in the building or to the rack's grounding strip/bus bar. Ensure the connection is secure using the provided external earthing screw and star washer. WARNING: Ensure a reliable grounded (earthed) connection before connecting power distribution products to AC power to reduce the risk of electric shock.

  3. Connect the PDU to a Power Source

    WARNING: To reduce the risk of fire or electric shock, ensure all circuit breakers are in the off position before connecting input power. If installing a Universal Input PDU, first open the input cord connector latches on the PDU, insert the input cord plug, and close the latches to lock it. Turn the feed circuit breaker for the power source OFF. Ensure all circuit breakers on the PDU are set to ON. Connect the PDU's input power cord to an appropriately rated, grounded (earthed) branch circuit electrical outlet. Turn the feed circuit breaker ON. Verify the OLED screen displays the Main Menu and outlet lights (if applicable) power up.

  4. Configure Universal Input PDU Input Type (if applicable)

    If installing a Universal Input PDU, connect to the PDU's Web interface (refer to the User Manual for instructions). Navigate to the 'System Management' page under settings. Select 'Set Input Cord' under actions, then choose the correct cord type from the pull-down menu. Select 'Save' and allow the PDU to reset. Incorrect selection may lead to inaccurate metering and incorrect power rating display.

  5. Secure Power Cords (Optional)

    For C13 and C19 outlets with integrated cord retention, plug in the power cord. Use the provided tie wraps to slide into the notch next to the desired outlet and wrap around the cord, then secure the tie wrap to prevent accidental disconnects. Alternatively, use optional locking power cords on compatible outlets.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.