nVent D902436SDA - Seismic Free-Stand DA Cabinet Type 12, 90x24x36, Lt Gray, Steel

nVent D902436SDA Seismic Free-Stand DA Cabinet Type 12, 90x24x36, Lt Gray, Steel

UPC: 783510305345


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent Seismic Free-Stand Dual-Access (DA) Cabinet Type 12 (SKU: D902436SDA) provides robust protection for critical equipment in demanding industrial, data center, and telecom environments. Its substantial 90x24x36-inch dimensions offer ample space for equipment. The dual-access design allows for front or front-and-rear access, enhancing usability and maintenance. Internal mounting channels are welded horizontally to the sides, accommodating 19-inch rack angles and panels that can be positioned anywhere along the channels. Security and durability are ensured by a 3-point latching system with oil-tight, key-locking handles and an oil-resistant door gasket. Concealed, easy-to-remove hinges and high-impact thermoplastic data pockets are also featured. For enhanced seismic resilience, optional accessories are available to achieve GR-63-CORE Zone 4 certification. Lifting eyes are included for simplified handling during installation. Integral vertical cable management is provided on 36-inch wide models.
  • Reinforced stainless steel construction protects networking/communication equipment from dust, liquid, and seismic activity
  • Six seismic bottom-mounting plates made of painted plated steel for 5/8-inch diameter anchors
  • Lifting eyes installed for ease of handling
  • Rack angles included are infinitely adjustable from front-to-rear supporting multiple networking/communication equipment configurations
  • 36-inch wide models include integral, vertical, RU-aligned fingers for supporting copper and fiber networking cables
  • AC models available for heat management
  • Data pockets included for equipment information management/organization
  • Data pockets are high-impact thermoplastic
  • Internal mounting channels welded horizontally to sides at top, bottom and center
  • 36-in. wide models include 2 Seismic Rack Panel Kits with EIA 310 specified square-holes (.375 x .375) that are infinitely adjustable front to rear

Specifications

Application
Datacom and Telecom Equipment;Networking, Storage and Data Center
Application
Networking, Storage and Data Center; Datacom and Telecom Equipment
Color
Lt Gray
Color
Light Gray
Color
Gray
Color Code
RAL 7035
Depth
36.14 in
Depth
918 mm
Finish
Powder Coated
Height
90.26 in
Height
2,293 mm
Material
Steel
Material
Mild Steel
Modification Services
Yes
Nema Rating
Type 12
Product Type
Standard
Rack Units
42 U
Series
Seismic Free-Stand DA Cabinet
Size
90x24x36
Thickness
2.66 mm
Thickness
12 ga
Thickness
51.40mm (2.024")
Type
Data Networking Freestanding Cabinets
Weight
590 lb
Width
613 mm
Width
24.12 in
Package Dimensions (L x W x H)
50 IN x 33 IN x 99 IN
Package Dimensions (L x W x H)
127 cm x 83.82 cm x 251.46 cm
Package Weight (Imperial)
590.000 L
Package Weight (Metric)
267.624 kg
Seismic Free-Stand DA Cabinet Type 12, 72x24x36, Lt Gray, Steel

D722436SDA

Seismic Free-Stand DA Cabinet Type 12, 72x24x36, Lt Gray, Steel
DTT 6201 230V SC 7035

13256241055

DTT 6201 230V SC 7035
AIR CONDIT 3500BTU 460V LG

DTT6201B460LG

AIR CONDIT 3500BTU 460V LG
SpectraCool Advanced Corrosion Protection Lvl 1, 12000BTU 115V, Lt Gray, Steel

G521216G700

SpectraCool Advanced Corrosion Protection Lvl 1, 12000BTU 115V, Lt Gray, Steel
SpectraCool Advanced Corrosion Protection Lvl 2, 12000BTU 115V, Lt Gray, Steel

G521216G800

SpectraCool Advanced Corrosion Protection Lvl 2, 12000BTU 115V, Lt Gray, Steel
SpectraCool Advanced Corrosion Protection Lvl 2, 8000BTU 115V, Brushed, SS316

G520816G802

SpectraCool Advanced Corrosion Protection Lvl 2, 8000BTU 115V, Brushed, SS316
SpectraCool Advanced Corrosion Protection Lvl 1 with RAC, 8000BTU 230V, Lt Gray, Steel

G520826G360

SpectraCool Advanced Corrosion Protection Lvl 1 with RAC, 8000BTU 230V, Lt Gray, Steel
SpectraCool Advanced Corrosion Protection Lvl 2, 8000BTU 460V, Brushed, SS316

G520846G802

SpectraCool Advanced Corrosion Protection Lvl 2, 8000BTU 460V, Brushed, SS316

How to Safely Handle and Install Large Hoffman Enclosures

This guide provides instructions for safely handling and installing large Hoffman enclosures, emphasizing precautions to prevent injury and equipment damage.

Estimated time: 1h

Tools needed:

Forklift, Overhead lifting device (e.g., crane), Slings with load-rated hooks or shackles, ROLL•A•LIFT™ or similar device (for some models)

Supplies needed:

3000 lb.-rated chain or strap (for securing to forklift mast), Rigging equipment (for overhead lifting)

  1. Read Safe Handling Requirements

    Before moving or installing the enclosure, thoroughly read and understand the 'Large Enclosure Safe Handling Requirements' document that accompanied the enclosure. Ensure the route is clear of obstructions and all personnel are at a safe distance.

  2. Prepare for Movement

    Ensure the enclosure is stabilized before removing any strapping. Verify that the lifting equipment (forklift or overhead device) has a sufficient load rating for the enclosure's weight and size. Only trained and authorized personnel should operate the lifting equipment.

  3. Position Forklift Forks

    For forklift handling, spread the forks to the maximum distance or as dictated by the skid width. Enter the skid from the rear (Side A) of the enclosure. Position the enclosure carefully on the forks, keeping the load against the carriage/mast and tilting the load backward towards the mast.

  4. Secure Enclosure to Forklift

    If using a forklift, secure the enclosure to the forklift mast before moving. Insert a 3000 lb.-rated chain or strap through the eye bolts provided on top of the enclosure and fasten it securely to the forklift mast assembly. Ensure sufficient tension to prevent tipping.

  5. Lift and Transport Enclosure

    Lift the enclosure a minimum distance so the skid is just clear of the floor. Start and stop the forklift slowly and gradually, avoiding jerky movements. Drive slowly with the forks carried as low to the ground as possible. Never attempt to move more than one enclosure at a time.

  6. End Loading/Unloading (if applicable)

    For end loading/unloading on trailers, spread forks to match pallet end slot openings and enter from the narrow side (C or D). Secure the enclosure to the forklift mast using chains or straps. Tilt the mast to take weight off the opposite end and slide/push the enclosure as required. Do not use chains or straps to lift the enclosure.

  7. Overhead Lifting (if applicable)

    If using overhead lifting, attach rigging to the eye bolts, ensuring the angle between lifting cables and the vertical does not exceed 45 degrees. Use slings with adequate load-rated hooks or shackles. Ensure the load rating of the lifting device and rigging is sufficient. Do not use ropes or cables through eye bolts.

  8. Final Placement

    Once the enclosure is at its final location, carefully position it. Ensure it is stable and permanently installed according to any specific product instructions not covered in this general handling guide. Refer to the nameplate or datasheet for model-specific details.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.