Overview

The nVent SpectraCool Advanced Corrosion Protection Level 2 Air Conditioner (SKU: G520846G802) delivers robust, reliable enclosure cooling for the most demanding industrial environments. Designed for high-performance applications where corrosion resistance and operational durability are critical, this 8,000 BTU unit operates at 460V and features a durable 316 stainless steel construction with a brushed finish. Engineered by nVent, a global leader in thermal management and electrical solutions, the SpectraCool series is trusted by engineers, facility managers, and OEMs across industries such as oil & gas, chemical processing, food & beverage, and heavy manufacturing. Its advanced corrosion protection ensures long-term reliability even in harsh, humid, or chemically aggressive settings, making it ideal for outdoor enclosures, control panels, and sensitive electronic equipment housings. This air conditioner is part of nVent’s SpectraCool family, which offers three cooling capacities tailored to diverse thermal loads. The G520846G802 model is specifically optimized for high-voltage applications requiring precise temperature control and minimal maintenance. Its three-phase 460V power input ensures compatibility with industrial electrical systems, while the 316 stainless steel housing provides superior resistance to salt spray, chlorides, and other corrosive agents—far exceeding standard painted or coated alternatives. The unit’s clean, professional appearance integrates seamlessly into control rooms, switchgear enclosures, and data centers where aesthetics and performance are equally important. Installation is streamlined thanks to the filterless design, which eliminates the need for routine filter maintenance and reduces downtime. The compact, modular form factor allows for easy mounting on NEMA-rated enclosures or standalone pedestals, and the unit’s internal components are engineered for vibration resistance and extended service life. nVent’s commitment to innovation is evident in the SpectraCool series, which incorporates advanced heat exchanger technology for efficient thermal transfer and energy savings. Whether deployed in a refinery, a pharmaceutical cleanroom, or a wastewater treatment facility, this air conditioner ensures consistent cooling performance, protecting critical electronics from overheating and premature failure. Key benefits of the nVent SpectraCool G520846G802 include: - Level 2 corrosion protection for harsh environments, extending equipment lifespan and reducing replacement costs. - High-capacity cooling (8,000 BTU) to maintain optimal operating temperatures in large or densely packed enclosures. - 460V three-phase power compatibility, aligning with industrial electrical standards for seamless integration. - Durable 316 stainless steel construction with a brushed finish, offering superior resistance to corrosion, moisture, and chemicals. - Filterless design for low-maintenance operation and reduced operational costs over time. nVent’s reputation as a trusted provider of thermal management solutions is built on decades of engineering excellence and a deep understanding of industrial challenges. The SpectraCool series reflects this expertise, combining robust construction, advanced materials, and user-centric design to deliver uncompromising performance. For facilities where reliability, durability, and compliance with stringent environmental standards are non-negotiable, the G520846G802 stands as a premier choice for enclosure cooling.
  • Attractive industrial design with minimal use of visible fasteners
  • Advanced Corrosion Protection Level 1 (ACP L1) Protection Includes: Protective coatings only applied to copper tubing and coils on the condenser (exterior facing) side as well as thermostat coatings
  • Energy-efficient rotary compressor on most models
  • Advanced Corrosion Protection Level 2 (ACP L2) Protection Includes: Everything that was coated in ACP L1, plus protective coatings applied to the evaporator (interior facing ) side and an additional wrap around the thermostat
  • Cleanable, reusable aluminum mesh filter included to protect coils for maximum cooling performance in dirty environments
  • Reliable mechanical thermostat on enclosure side of the unit
  • All G-series come standard with two separate thermostats for cooling and heating when a heater is equipped
  • Operating temperature range from -40 F/-40 C to 131 F/55 C
  • Dust-resistant condenser coil allows the unit to be run filterless in most indoor applications
  • Dual condenser-side air movers for performance redundancy on G52 and G57 models

Specifications

Ambient Temperature
40 Deg C
Ambient Temperature
-40-131 °F
Application
Controls and Drives;Corrosive Environments;Power Distribution
Application
Corrosive Environments; Power Distribution; Controls and Drives
Color
Unpainted
Color
Brushed
Corrosion Resistant
Yes
Depth
296 mm
Depth
11.66 in
Finish
Brushed #4
Height
1,338 mm
Height
52.69 in
Material
Stainless Steel 316
Material
Stainless Steel 316L
Max Current
3.2 A
Mounting
Side wall
NEMA Rating
4X Watertight, corrosion-resistant
Nominal Capacity Btu/h
8,000 Btu/h
Nominal Capacity Watts
3,500 W
Nominal Voltage
460 V
Number Of Phases
3
Operating Temperature
-40-55
Operating Temperature
-40-131 °F
Operating Temperature
-40-55 °C
Outdoor Installation
Yes
Poles
3P
Product Family
SpectraCool
Protection Rating
NEMA Type 4X
Refrigerant
R513A
Remote Access Control
No
Series
SpectraCool
Size
8000 BTU
Thickness
1.21 mm
Thickness
18 ga
Thickness
51.40mm (2.024")
Type
Air Conditioners
Voltage AC
400-460 V
Voltage Rating
460 V
Weight
62.6 kg
Weight
128 lb
Width
17.12 in
Width
435 mm
Package Dimensions (L x W x H)
52.7 IN x 17.14 IN x 11.65 IN
Package Dimensions (L x W x H)
133.858 cm x 43.5356 cm x 29.591 cm
Package Weight (Imperial)
128.000 L
Package Weight (Metric)
58.061 kg
SpectraCool Advanced Corrosion Protection Lvl 1, 8000BTU 460V, Brushed, SS316

G520846G102

SpectraCool Advanced Corrosion Protection Lvl 1, 8000BTU 460V, Brushed, SS316
DTS 3081 115V Type 4/4X 304 SS

13382344300

DTS 3081 115V Type 4/4X 304 SS
AC Unit 12-25000 BTU/H 460V - NEMA 4X -SS

DTS3681C460N4SS

AC Unit 12-25000 BTU/H 460V - NEMA 4X -SS
InRow RC 300mm Chilled Water

ACRC301S

InRow RC 300mm Chilled Water
SpectraCool Advanced Corrosion Protection Lvl 2, 12000BTU 230V, Lt Gray, Steel

G521226G800

SpectraCool Advanced Corrosion Protection Lvl 2, 12000BTU 230V, Lt Gray, Steel
SpectraCool Advanced Corrosion Protection Lvl 1, 12000BTU 230V, Lt Gray, Steel

G521226G700

SpectraCool Advanced Corrosion Protection Lvl 1, 12000BTU 230V, Lt Gray, Steel
SpectraCool Advanced Corrosion Protection Lvl 1, 12000BTU 460V, Lt Gray, Steel

G521246G700

SpectraCool Advanced Corrosion Protection Lvl 1, 12000BTU 460V, Lt Gray, Steel
SpectraCool Advanced Corrosion Protection Lvl 1, 8000BTU 230V, Lt Gray, Steel

G520826G700

SpectraCool Advanced Corrosion Protection Lvl 1, 8000BTU 230V, Lt Gray, Steel

How to Install the G520846G802 SPECTRACOOL Air Conditioner

Installation guide for mounting and wiring the G520846G802 SPECTRACOOL Air Conditioner.

Estimated time: 45m

Tools needed:

Screwdriver, Wrench, Ratchet driver

Supplies needed:

Mounting gasket kit, Copper conductors, Slow blow or HACR circuit breaker

  1. Test Functionality

    Inspect the air conditioner and verify correct functionality before mounting. If the unit has been in a horizontal position, ensure it remains upright for at least five (5) minutes before operating. Do not operate the unit while it is horizontal or on its side, back, or front, as this can cause permanent damage and void the warranty. Refer to the nameplate for electrical requirements and wire the unit to a properly grounded power supply using only copper conductors. The minimum circuit ampacity should be at least 125% of the amperage shown on the unit nameplate. No other equipment should be connected to this circuit. Immediately after applying power, the evaporator blower should start. Operate the air conditioner with the compressor running for five (5) to ten (10) minutes by setting the cooling thermostat or controller setpoint below the ambient temperature. Condenser air temperatures should become warmer than normal room temperatures within a few minutes after the condenser impellers start.

  2. Install Mounting Gasket

    Using the provided mounting gasket kit, install the gaskets to the air conditioner according to Figure 1.

  3. Mount the Air Conditioner

    Mount the air conditioner onto the enclosure, taking care not to damage the mounting gasket, which provides the seal between the unit and the enclosure. Avoid dragging the air conditioner on the enclosure with the gasket attached to prevent rips or tears. Start mounting bolts by hand before tightening with a wrench or ratchet driver to avoid cross-threading.

  4. Connect Power Supply

    Refer to the nameplate for electrical requirements and wire the unit to a properly grounded power supply. The unit's terminal block is located behind the evaporator access panel on the rear (enclosure side) of the unit. For 3-phase units, after applying power, verify that the phase monitor light is illuminated, indicating correct electrical phasing. The electrical circuit should be fused with a slow blow or HACR circuit breaker.

  5. Set Thermostat or Controller

    If the air conditioner requires a remote-mounted thermostat, wire the thermostat outputs to the appropriate terminals on the 24 VAC terminal strip, referencing the correct wiring diagram. Set the thermostat or controller setpoints for the required cabinet temperature. Refer to the Sequence of Operation on page 4 for thermostat adjustment and operation, or page 15 for controller setpoint adjustment and operation. Note that the thermostat dial may be protected by a plastic bushing during shipment; remove and replace it to adjust the thermostat. Do not set the enclosure thermostat to a temperature lower than 70 F for normal operation, as this can cause coil freeze-ups.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.