Contact for Pricing
Overview
- Easy maintenance: hinged front cover allows quick access to all components; condenser coil can be cleaned while unit is still mounted to the cabinet
- Smooth surface with minimal use of visible fasteners
- Cleanable reusable aluminum mesh filter protects coils for maximum cooling performance
- R134a, R513A or R407C Refrigerant
- Models for 115, 230 and 460 single phase VAC power input
- Operating temperature range from -40 F/-40 C to 131 F/55 C (with optional low-ambient package)
- Reliable mechanical thermostat located behind the filter of the unit
- Robust reciprocating compressor
- Low-carbon mild-steel sheet-metal cover for rugged factory and outdoor environments
- High-performance fans and blowers designed for densely packed enclosures
Specifications
Amperage Rating | 2.5 A |
Application | Controls and Drives;Corrosive Environments;Power Distribution |
Application | Controls and Drives; Power Distribution; Corrosive Environments |
Btu Rating | 1,600 |
Color | Brushed |
Color | Unpainted |
Color | Brushed stainless steel |
Current Rating | 2.2/2.2A |
Depth | 222 mm |
Depth | 8.75 in |
Finish | Brushed #3 |
Frequency | 50/60Hz |
Frequency Rating | 50/60 Hz |
Frequency Rating, Maximum | 60 Hz |
Frequency Rating, Minimum | 50 Hz |
Height | 23 IN |
Height | 584 mm |
Housing Material | Stainless Steel |
Material | Stainless Steel 304 |
Material | SS304 |
Max Current | 1.7 A |
Mechanical Advantage | Stainless steel optional |
NEMA Rating | Type 3R |
NEMA Rating | 12 Indoor, dust-resistant |
Nominal Capacity Btu/h | 1,733 Btu/h |
Nominal Capacity Watts | 508 W |
Nominal Voltage | 230 V |
Number Of Phases | 1 |
Operating Temperature | -40-131 |
Operating Temperature | -40-55 |
Operating Temperature | 131 deg F |
Operating Temperature | -40-55 °C |
Power | 469 W |
Product Family | ProAir |
Protection Rating | NEMA Type 12 |
Remote Access Control | No |
Series | ProAir Harsh Environment |
Series | ProAir Harsh Environment Outdoor |
Size | 1600BTU |
Thickness | 1.21 mm |
Thickness | 18 ga |
Thickness | 51.40mm (2.024") |
Type | Air Conditioners |
Voltage AC | 200-250 V |
Voltage Rating | 230V |
Voltage Rating | 230 V |
Weight | 26 kg |
Weight | 67 lb |
Width | 254 mm |
Width | 10 IN |
Package Dimensions (L x W x H) | 21 IN x 14 IN x 27 IN |
Package Dimensions (L x W x H) | 53.34 cm x 35.56 cm x 68.58 cm |
Package Weight (Imperial) | 67.000 L |
Package Weight (Metric) | 30.391 kg |

CR230226G015
AC, Side Mtg 230v 50/60Hz, L2, Bulletin MCL (Air Conditioners - McLean Midwest Side-Mount Air Conditioners), Size/Dims: 1500/1700 BTU, Material: Steel, Finish: Lt GrayHow to Install the CR230226G016 Air Conditioner
Installation guide for mounting and wiring the CR230226G016 air conditioner.
Estimated time: 45m
Tools needed:
Screwdriver, Wrench, Ratchet driver
Supplies needed:
Mounting gasket kit, Mounting bolts, Washers
- Inspect and Test Functionality
Inspect the air conditioner for any shipping damage. Verify its functionality by operating it for 5-10 minutes. Ensure no excessive noise or vibration is present, and that the condenser blower, evaporator blower, and compressor are running. Condenser air temperatures should become warmer than room temperature within minutes. If the unit was in a horizontal position, ensure it has been upright for at least 5 minutes before testing. Do not operate the unit while horizontal, as this can damage the compressor and void the warranty.
- Prepare Enclosure Openings
Using the cutout dimensions provided in this manual, prepare the enclosure for the air 'IN' and air 'OUT' openings, as well as the mounting bolt hole pattern.
- Install Gaskets
Apply the provided mounting gasket kit to the rear of the air conditioner according to the instructions on page 6.
- Mount the Air Conditioner
Mount the air conditioner onto the enclosure using the provided mounting bolts and washers. Start bolts by hand to avoid cross-threading, then tighten with a wrench or ratchet driver. Ensure the unit remains upright during operation.
- Connect Power Supply
Refer to the top of the nameplate for electrical requirements. Connect the power cord to a properly grounded power supply. Use of an extension cord is not recommended. The electrical circuit should be fused with a slow blow or HACR circuit breaker. Check the nameplate or datasheet for specific electrical current requirements, as minimum circuit ampacity should be at least 125% of the amperage shown.
- Adjust Temperature Controller (if applicable)
If the unit is equipped with an automatic temperature controller, it is preset at the factory. For Level I controllers, disconnect power, open the front panel, and adjust the controller screw clockwise to decrease or counter-clockwise to increase the temperature set point. For Level II and III controllers, refer to the separate programming manual. After adjustment, close the front panel and restore power.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.