nVent CP4420W Concept Panel, fits 44.00x20.00 inch Enclosure, Unpainted, Wood
UPC: 783510237875
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Painted white or conductive finish
- Include a formed flange along any side that is longer than 22.20 in (564 mm)
- Optional wood panels are made of 3/4-in plywood, pre-cut and pre-drilled to install on panel mounting studs in the rear of the cabinet
- Compatible with nVent CP2442 and CP2442G mounting
- Suitable for industrial control and electrical applications
Specifications
Application | Datacom and Telecom Equipment; Networking, Storage and Data Center |
Application | Datacom and Telecom Equipment;Networking, Storage and Data Center |
Color | Unpainted |
Finish | Smooth Matte |
Height | 42.2 in |
Height | 1,072 mm |
Material | Wood |
Material | Plywood |
Material | Plywood;Wood |
Modification Services | Yes |
Product Family | Concept |
Thickness | 19 mm |
Thickness | 0.75 in |
Type | Industrial Panels and Panel Accessories;Wood |
Type | Industrial Panels and Panel Accessories |
Type | Wood |
Weight | 11.5 lb |
Width | 18.2 in |
Width | 462 mm |
Works With | NEMA |
Package Dimensions (L x W x H) | 43 IN x 19 IN x 1.5 IN |
Package Dimensions (L x W x H) | 109.22 cm x 48.26 cm x 3.81 cm |
Package Weight (Imperial) | 11.500 L |
Package Weight (Metric) | 5.216 kg |

ST4803PDGM
Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .
3085
Super-Safeway® Multiple Outlet Box, Extended Depth, 2-Sided, F2 (1/2") Cord Grip Body, with Flip Lids for (2) Duplex Not Included
F62ERLNSNSNM002
OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL
CPP24FMWBLY
The Mini-Com Flush Mount Modular Patch Panel accepts up to 24 Mini-Com Modules for unshielded applications in 1 RU, and mounts to 19 inch and 23 inch racks and cabinets. The panel mounts flush with the rack and can be identified with adhesive labels and is black.
CESUM3-C15
Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.
UTP6AL1MBU
The TX6A™ 10Gig Cat 6A UTP Patch Cord is a 1-Meter, Blue cord constructed of 24 AWG, unshielded, twisted pair stranded, LSZH (60332-1) cable with high-performance modular plugs. Its MaTriX Tape Technology limits alien crosstalk, ensuring 10 Gb/s transmission. The tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.How to Install the CP4420W Wall-Mount Enclosure
Follow these instructions to properly mount and install your CP4420W wall-mount enclosure.
Estimated time: 1h
Tools needed:
Drill, Level, Measuring tape, Screwdriver, Wrench or socket set
Supplies needed:
Mounting hardware (screws, anchors, bolts), Gasket (if applicable), Sealing fittings (if applicable)
- Select Mounting Location
Choose a suitable location for the enclosure. Ensure the mounting surface is strong enough to support the weight of the enclosure and its contents. Consider environmental factors such as temperature, humidity, and potential exposure to corrosive elements. Refer to the datasheet for specific environmental ratings.
- Prepare the Enclosure
If necessary, install any required accessories such as internal mounting panels, gland plates, or door stops. Ensure the gasket is properly seated around the door flange for a watertight seal. If using sealing fittings for cable entry, install them according to their specific instructions.
- Mark Mounting Holes
Hold the enclosure in the desired position against the mounting surface. Use a level to ensure it is straight. Mark the locations for the mounting holes through the designated mounting points on the back of the enclosure or the internal mounting panel.
- Drill Mounting Holes
Remove the enclosure from the mounting surface. Drill the mounting holes at the marked locations. If mounting to a concrete or masonry surface, use appropriate masonry bits and install anchors. If mounting to a metal surface, ensure the holes are appropriately sized for the chosen fasteners.
- Mount the Enclosure
Position the enclosure over the drilled holes. Secure the enclosure to the mounting surface using appropriate hardware (screws, bolts, etc.). Ensure the enclosure is firmly attached and does not move. Use a wrench or socket set for tightening bolts as needed.
- Install Equipment and Wiring
Install any internal equipment according to its specific instructions. Route wiring through the appropriate conduit or cable entries, ensuring proper strain relief and sealing. Refer to the wiring diagrams provided with the equipment and the enclosure datasheet for guidance on wire management and sealing.
- Final Inspection
Close and latch the enclosure door securely. Verify that all seals are properly engaged and that the enclosure is watertight or weatherproof as required by its rating. Double-check that all mounting hardware is tight and that the installation is secure.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.