Authorized nVent Distributor
nVent CDR3P12 - Concept DIN3 Rail Kits, fits 12-inch Concept Enclosure, Plated, Mild Steel

nVent CDR3P12 Concept DIN3 Rail Kits, fits 12-inch Concept Enclosure, Plated, Mild Steel

UPC: 783510790301


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent CDR3P12 DIN3 Rail Kit provides a durable, plated mild steel mounting solution for 12-inch nVent Concept enclosures. This kit includes three DIN rails and all necessary mounting hardware, enabling secure installation of DIN 1, DIN 3, or CENELEC style snap-on devices. Rails can be mounted vertically or horizontally, attaching to the enclosure's rear collar stud or mounting channels for flexible configuration. Constructed from 12-gauge plated steel, the CDR3P12 ensures long-term durability and resistance in industrial environments. It facilitates organized mounting of components such as circuit breakers, terminal blocks, and relays, enhancing enclosure efficiency and maintainability. Ideal for manufacturing, automation, and control systems, this kit ensures compatibility and reliable performance within the nVent Concept enclosure ecosystem. The kit is designed for 12-inch Concept enclosures (A or B = 12.00 in. / 305 mm) and is manufactured in the US.
  • Kit includes three rails and mounting hardware
  • Kit includes three rails and mounting hardware
  • Rails mount vertically or horizontally to rear collar stud or mounting channels
  • Constructed from durable 12-gauge plated mild steel for industrial environments
  • Designed for 12-inch Concept enclosures (A or B = 12.00 in. / 305 mm)

Specifications

Application
Controls and Drives
Color
Unpainted
Finish
Plated
Fits Concept Enclosure
When A or B = 12.00 in. (305 mm)
Fits Height
2000 mm mm
Fits Height
12 in
Fits Width
12 in
Material
Plated Mild Steel
Material
Mild Steel;Steel
Material
Mild Steel
Modification Services
Yes
Mounting Type
DIN Rail Mount
Product Family
Concept
Series
Concept
Size
fits 12.00 in
Size
Fits 12-inch Concept Enclosure
Thickness
0.04 in
Thickness
51.40mm (2.024")
Type
Internal Mounting for Industrial Enclosures
Weight
0.7 lb
Works With
NEMA
Package Dimensions (L x W x H)
11 IN x 9.5 IN x 1 IN
Package Dimensions (L x W x H)
27.94 cm x 24.13 cm x 2.54 cm
Package Weight (Imperial)
0.700 L
Package Weight (Metric)
0.318 kg
Concept DIN3 Rail Kits, fits 16-inch Concept Enclosure, Plated, Mild Steel

CDR3P16

Concept DIN3 Rail Kits, fits 16-inch Concept Enclosure, Plated, Mild Steel
clip - aluminum - for mounting enclosures to 35 mm wide DIN rails.

1427DIN42M

clip - aluminum - for mounting enclosures to 35 mm wide DIN rails.
Pre-Fabricated Floor-Track Vertical Mounting Bracket with Supporting Horizontal Cross Bar, 12 Inch or 18 Inch Height, For 4 Inch Square of 4-11/16 Inch Square Boxes, Deep or Shallow, with Standard Device Covers (Mud Rings)

SV1218

Pre-Fabricated Floor-Track Vertical Mounting Bracket with Supporting Horizontal Cross Bar, 12 Inch or 18 Inch Height, For 4 Inch Square of 4-11/16 Inch Square Boxes, Deep or Shallow, with Standard Device Covers (Mud Rings)
This is a 24" electrical box mounting bracket that mounts a 1-1/2" electrical box to studs on 24" centers. It is made of pre-galvanized steel. The finish/color is silver.

BMB24

This is a 24" electrical box mounting bracket that mounts a 1-1/2" electrical box to studs on 24" centers. It is made of pre-galvanized steel. The finish/color is silver.
ARCA JIC 10 x 8 x 6 with knockouts, hinged opaque cover, SS latch, padlockable

ARK1086CHSSL

ARCA JIC 10 x 8 x 6 with knockouts, hinged opaque cover, SS latch, padlockable
NEXT ENC 84HX40WX11D N1 PAINTED

ER8440A

NEXT ENC 84HX40WX11D N1 PAINTED
MULTIPOLAR FLAT MOUNTING BUSBAR SUPPORT SB 6500 4 POLES

50265410

MULTIPOLAR FLAT MOUNTING BUSBAR SUPPORT SB 6500 4 POLES
The nVent CGS142 cable gland is engineered for superior performance in demanding industrial applications. Designed to provide a secure and reliable connection for cables, this product ensures protection against environmental hazards such as moisture, dust, and mechanical stress. Its robust construction and precise engineering make it ideal for use in industries like manufacturing, oil and gas, and renewable energy. The CGS142 is manufactured in the US, adhering to stringent quality standards, and is compatible with a wide range of cable types. Its easy installation and maintenance features reduce downtime and enhance operational efficiency. Trust nVent for high-quality cable management solutions that deliver durability and performance.

CGS142

The nVent CGS142 cable gland is engineered for superior performance in demanding industrial applications. Designed to provide a secure and reliable connection for cables, this product ensures protection against environmental hazards such as moisture, dust, and mechanical stress. Its robust construction and precise engineering make it ideal for use in industries like manufacturing, oil and gas, and renewable energy. The CGS142 is manufactured in the US, adhering to stringent quality standards, and is compatible with a wide range of cable types. Its easy installation and maintenance features reduce downtime and enhance operational efficiency. Trust nVent for high-quality cable management solutions that deliver durability and performance.

How to Mount DIN Rails in an Enclosure

Instructions for mounting DIN rails within a Hoffman enclosure, either directly to studs or to mounting channels.

Estimated time: 30m

Tools needed:

Torque wrench

Supplies needed:

DIN rails, M8 flanged nuts, Channel nuts, Pan head screws, Mounting channels (if applicable)

  1. Determine Mounting Method

    Decide whether to mount DIN rails directly to enclosure studs or to mounting channels. Mounting channels are sold separately.

  2. Mount DIN Rails to Enclosure Studs

    If mounting directly to enclosure studs, align the slots in the DIN rails with the studs. Attach an M8 flanged nut to each stud and torque to 99 in–lbs (11 Nm).

  3. Prepare for Mounting to Channels

    If mounting DIN rails to mounting channels, insert one channel nut for each DIN rail into each mounting channel.

  4. Attach Mounting Channels (if applicable)

    If using mounting channels, attach them to the enclosure studs according to their separate installation instruction sheet (Ref instruction 64317001).

  5. Mount DIN Rails to Channels

    Align the slots in the DIN rails with the channel nuts. Insert one pan head screw into each nut and torque to 50 in–lbs (5.6 Nm).

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.