Authorized nVent Distributor
nVent AU84X7824RSSLP - Universal Free-Stand Right Side Open, 84.13x77.99x24.13, Stainless Steel 304

nVent AU84X7824RSSLP Universal Free-Stand Right Side Open, 84.13x77.99x24.13, Stainless Steel 304

UPC: 783510389659


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent Universal Free-Stand Enclosure, SKU AU84X7824RSSLP, is engineered for demanding industrial environments, offering unparalleled flexibility and robust protection for critical equipment. Constructed from high-grade Stainless Steel 304, this enclosure is built to withstand corrosive atmospheres, extreme temperatures, and harsh washdown procedures, making it an ideal solution for applications across manufacturing, food and beverage processing, chemical plants, and outdoor installations. Designed for versatility, the Universal Free-Stand series allows for seamless baying of one- and two-door models, enabling the creation of application-specific configurations tailored to your operational needs. This modular approach ensures that you can scale your enclosure solutions as your requirements evolve, providing a cost-effective and adaptable infrastructure for your control systems, power distribution, and automation components. The right-side opening configuration of this specific model, AU84X7824RSSLP, offers convenient access for maintenance and operation in layouts where side access is prioritized. Key benefits of the nVent Universal Free-Stand Enclosure include: * **Superior Material Durability:** Stainless Steel 304 construction provides exceptional resistance to corrosion, rust, and chemical attack, ensuring long-term reliability and equipment integrity. * **Flexible Configuration Options:** The ability to bay enclosures together allows for custom-sized solutions, accommodating a wide range of equipment and operational layouts. * **Enhanced Safety Features:** nVent prioritizes safety, and this enclosure is designed to protect both personnel and equipment from environmental hazards and electrical risks. Optional accessories are available to further enhance safety and functionality. * **Versatile Application Suitability:** Suitable for both indoor and outdoor use, this enclosure meets the stringent demands of modern industrial settings. * **Generous Dimensions:** With a substantial size of 84.13x77.99x24.13 inches, it provides ample space for complex electrical and control systems, facilitating efficient wiring and component layout. When selecting an enclosure for critical industrial applications, factors such as environmental protection (NEMA/IP ratings), material compatibility, physical dimensions, and ease of access for maintenance are paramount. The nVent Universal Free-Stand Enclosure excels in these areas, offering a reliable and secure housing for sensitive electronics and power distribution equipment. Its robust construction and thoughtful design, backed by the trusted nVent brand, ensure that your valuable assets are protected against the elements and operational challenges. Professionals choose nVent for its commitment to quality, innovation, and providing solutions that enhance operational efficiency and safety in the most demanding industrial environments. The UNSPSC code 39121324 further categorizes this product within the electrical enclosure systems market, highlighting its specific industrial application.
  • Seams are continuously welded and ground smooth
  • Body stiffeners in larger enclosures for extra rigidity
  • Body flange trough excludes liquids and contaminants
  • Heavy-duty lifting eyes anchor into reinforced top
  • Concealed, easy-to-remove hinges
  • Heavy-duty 3-point latching mechanism operated by padlocking handle on all doors
  • Order panels separately
  • Data pocket is high-impact thermoplastic
  • Oil-resistant door gasket
  • Bonding provision on door

Specifications

Application
Arc Flash Safety; Controls and Drives; Power Distribution
Application
Arc Flash Safety;Controls and Drives;Power Distribution
Body Thickness
12 ga
Body Thickness
2.66 mm
Body Thickness
16 ga
Cable Entry
No
Color
None
Color
Unpainted
Conductive Panel
A84PM78G
Connection
Yes
Cubic Capacity
91 in3
Depth
613 mm
Depth
24.13 in
Depth
613
Door Thickness
12 ga
Door Thickness
2.66 mm
Door Thickness
14 ga
Finish
Brushed
Height
2,137
Height
84.13 in
Height
2,137 mm
Insulation
False
Insulation
No
Material
Stainless Steel 304
Material Quality
Stainless Steel 304
Material Quality
Stainless steel V2A
Mounting
Free Standing
NEMA Rating
Type 4X, 4, 12, 3R
NEMA Rating
12;4;4X
Number Of Outlet
1
Painted Panel
A84PM78
Panel Size
72.00 x 33.75 in
Panel Size
1829 x 857 mm
Protection Rating
NEMA Type 4
Size
84.13 x 77.99 x 24.13 inch
Type
Stainless Steel Freestanding Industrial Enclosures
Weight
652 lb
Width
1,981
Width
77.99 in
Width
1,981 mm
Package Dimensions (L x W x H)
85 IN x 37 IN x 94 IN
Package Dimensions (L x W x H)
215.9 cm x 93.98 cm x 238.76 cm
Package Weight (Imperial)
778.000 L
Package Weight (Metric)
352.901 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco

36297702

Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

Frequently Asked Questions

What are the dimensions of the AU84X7824RSSLP enclosure?

The enclosure has a height of 84.13 inches, a width of 77.99 inches, and a depth of 24.13 inches.

What material is the AU84X7824RSSLP enclosure made from?

The enclosure is constructed from Stainless Steel 304 with a brushed finish.

What is the weight of the AU84X7824RSSLP enclosure?

The enclosure weighs 652lb.

What industry standards does this enclosure meet?

It is UL 508A Listed and cUL Listed, meeting NEMA Type 4X, 4, 12, 3R, and IEC 60529 IP66 standards.

What is the impact rating of this enclosure?

The enclosure has an IK10 Impact Rating according to IEC 62208.

What type of latching mechanism does the enclosure use?

It features a heavy-duty 3-point latching mechanism operated by a padlocking handle on all doors.

What is the body and door thickness?

Both the body and door have a thickness of 12ga.

Does the enclosure come with internal panels?

No, panels must be ordered separately for this enclosure.

What is the door gasket material?

The enclosure is equipped with an oil-resistant door gasket.

How is the enclosure protected against liquids and contaminants?

The body flange trough is designed to exclude liquids and contaminants.

How to Safely Handle and Install a Hoffman Enclosure

This guide provides instructions for safely handling and installing Hoffman enclosures, emphasizing precautions to prevent injury and equipment damage.

Estimated time: 1h

Tools needed:

Forklift, Overhead lifting device, Slings with hooks or shackles, Chain or strap (3000 lb-rated)

Supplies needed:

ROLL•A•LIFT™ or similar device (for some models)

  1. Read Safe Handling Requirements

    Before moving or installing the enclosure, read and follow all precautions in the Large Enclosure Safe Handling Requirements manual that accompanied the enclosure. Ensure the route is clear of obstructions and workers are at a safe distance.

  2. Prepare for Forklift Handling

    Ensure the forklift operator is trained and authorized. Know the safe lifting capabilities of the equipment and verify it can handle the enclosure's weight and size by checking the product label and nameplate data. Position enclosures far back on the forks with the load against the carriage/mast, tilting the load backward towards the mast.

  3. Secure Enclosure for Forklift Transport

    If using a forklift, secure the enclosure to the forklift mast before moving. For some models, insert a 3000 lb-rated chain or strap through the eye bolts provided on top of the enclosure and fasten securely to the forklift mast assembly. Ensure sufficient tension to prevent tipping. Do not use chains or straps for lifting, only for preventing tipping.

  4. Move Enclosure with Forklift

    Start and stop the forklift slowly and gradually. Drive slowly with the forks carried as low to the ground as possible. Have a person assist the forklift operator at a safe distance to guide the enclosure.

  5. Prepare for Overhead Lifting

    If using overhead lifting, attach rigging to the eye bolts, ensuring the angle between lifting cables and the vertical does not exceed 45 degrees. Use slings with adequate load-rated hooks or shackles. Ensure the load rating of the lifting device and rigging is sufficient for the enclosure's weight.

  6. Perform Overhead Lift

    Select or adjust rigging lengths to compensate for any unequal weight distribution and to support the enclosure in an upright position. Do not allow the angle between lifting cables and the vertical to exceed 45 degrees.

  7. Position Enclosure

    Carefully position the enclosure on the forks or with the lifting device, ensuring the load is stable and secure. Avoid contacting fixed objects during transport. Lift the enclosure only the minimum distance necessary to clear the floor or for transport.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.