nVent AU72X4018RSSLP - Universal Free-Stand Right Side Open, 72.13x39.76x18.11, Stainless Steel 304
nVent

AU72X4018RSSLP

UPC: 783510389468


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent Universal Free-Stand Enclosure, SKU AU72X4018RSSLP, is engineered for robust protection and unparalleled flexibility in demanding industrial environments. Crafted from high-grade Stainless Steel 304, this enclosure offers superior corrosion resistance and durability, making it an ideal choice for both indoor and outdoor applications where equipment integrity is paramount. Its generous dimensions of 72.13 inches high, 39.76 inches wide, and 18.11 inches deep provide ample space for a wide array of electrical and electronic components, control systems, and instrumentation. The 'Universal Free-Stand' design emphasizes adaptability. This particular model features a right-side opening door, facilitating streamlined access for installation, maintenance, and operational checks. The free-standing nature allows for placement in virtually any location without the need for wall mounting, offering significant installation flexibility. These enclosures are designed to be bayed together, enabling the creation of custom, application-specific configurations. This modular approach is critical for expanding control systems or housing complex machinery in manufacturing plants, processing facilities, and other industrial settings. Safety and efficiency are core tenets of the nVent design philosophy. The robust construction of the AU72X4018RSSLP enclosure ensures that sensitive equipment is shielded from environmental hazards such as dust, moisture, and impact, thereby extending operational life and minimizing downtime. Furthermore, the enclosure design contributes to a safer working environment by protecting personnel from electrical hazards and ensuring that critical control systems remain secure and accessible only to authorized individuals. Key features and benefits include: * **Premium Stainless Steel 304 Construction:** Offers exceptional resistance to corrosion, chemicals, and harsh environmental conditions, ensuring long-term reliability. * **Versatile Free-Standing Design:** Provides placement flexibility and can be easily integrated into existing or new facility layouts. * **Bayable Configuration:** Allows for modular expansion and the creation of custom enclosure solutions to meet evolving operational needs. * **Right-Side Opening Door:** Facilitates convenient access for maintenance, wiring, and component management. * **Generous Internal Space:** Accommodates a wide range of industrial equipment, control panels, and electrical assemblies. * **Enhanced Safety:** Protects both equipment and personnel from environmental factors and electrical hazards. Applications for the nVent AU72X4018RSSLP enclosure span numerous industries, including but not limited to: * Industrial Automation and Control * Food and Beverage Processing * Water and Wastewater Treatment * Chemical Processing * Pharmaceutical Manufacturing * Power Generation and Distribution * Telecommunications Infrastructure When selecting an enclosure, professionals prioritize reliability, protection, and ease of integration. nVent, a trusted leader in enclosures and protection solutions, delivers on all these fronts. The AU72X4018RSSLP is a testament to their commitment to providing high-performance products that meet the rigorous demands of modern industry. Accessories are readily available to further enhance the functionality, safety, and customization of this versatile enclosure system, ensuring it perfectly aligns with your specific operational requirements.
  • Seams are continuously welded and ground smooth
  • Body stiffeners in larger enclosures for extra rigidity
  • Body flange trough excludes liquids and contaminants
  • Heavy-duty lifting eyes anchor into reinforced top
  • Concealed, easy-to-remove hinges
  • Heavy-duty 3-point latching mechanism operated by padlocking handle on all doors
  • Order panels separately
  • Data pocket is high-impact thermoplastic
  • Oil-resistant door gasket
  • Bonding provision on door

Specifications

Application
Power Distribution; Arc Flash Safety; Controls and Drives
Body Thickness
2.66 mm
Body Thickness
12 ga
Cable Entry
No
Color
None
Color
Unpainted
Conductive Panel
A72PM40G
Connection
Yes
Cubic Capacity
30 Cu-Ft
Depth
18.11
Depth
460
Depth
460 mm
Door Thickness
2.66 mm
Door Thickness
12 ga
Finish
Brushed
Height
72.13
Height
1,832
Height
1,832 mm
Insulation
False
Insulation
No
Material
Stainless Steel 304
Mounting
Free Standing
Mounting Type
Free-stand
NEMA Rating
Type 4X, 4, 12, 3R
Number Of Outlet
1
Painted Panel
A72PM40
Panel Size
1524 x 857 mm
Panel Size
60.00 x 33.75 in
Protection Rating
NEMA Type 4
Series
Universal Free-Stand
Size
72.13 x 39.76 x 18.11 inch
Size
72.13x39.76x18.11
Type
Stainless Steel Freestanding Industrial Enclosures
Weight
352 lb
Width
39.76
Width
1,010
Width
1,010 mm
Package Dimensions (L x W x H)
56 IN x 34 IN x 86 IN
Package Dimensions (L x W x H)
142.24 cm x 86.36 cm x 218.44 cm
Package Weight (Imperial)
352.000 L
Package Weight (Metric)
159.667 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the AU72X4018RSSLP Controller

This guide provides step-by-step instructions for installing and configuring the AU72X4018RSSLP controller, ensuring proper mounting, wiring, and initial setup.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the AU72X4018RSSLP controller to the designated mounting surface using appropriate screws. Ensure the controller is level and firmly attached.

  2. Connect the wiring

    Use wire strippers to prepare the wires and connect them to the terminal connectors on the controller. Follow the wiring diagram provided in the documentation to ensure correct connections.

  3. Verify connections

    Use a multimeter to check the voltage at the terminals to ensure proper power supply to the controller. Confirm that all connections are secure and correctly wired.

  4. Configure the controller settings

    Power on the controller and access the configuration menu. Set the required parameters according to your application needs, following the user manual for guidance.

  5. Calibrate the controller

    Perform any necessary calibration procedures as outlined in the documentation to ensure accurate operation of the controller.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.