
Contact for Pricing
Overview
- Material: AISI 304L / AISI 316L pre-grained stainless steel. Body: 1.5 mm. Door: 2 mm. Mounting plate: 2.5 mm galvanized steel.
- Body: Folded and seam welded. For ease of installation, each back corner of the enclosure is laser-marked to precisely indicate where to drill holes and affix AWS wall mounting brackets.
- Door: Corner formed in one piece. Surface mounted, with 130° opening. Concealed AISI 304 stainless steel hinges with captive pin. Sealing is ensured by an injected polyurethane gasket. For AISI 316L, sealing is ensured by an injected silicone gasket. Inne
- Lock: nVent HOFFMAN customized zamak double-bit 3 mm lock, with 90° movement and anti-vibration mechanism. Espagnolette three point locking. Stainless steel lock and other versions are available as accessories.
- Mounting plate: The mounting plate is marked vertically at 10 mm intervals, for easy horizontal positioning of equipment. On the top and bottom there are holes to facilitate cable fixing. Fixed onto M8 press welded studs to the rear of the enclosure. All
- Cable access: No gland plate openings as standard, to maximise sealing and cleanliness.
- Finish: 400 pre-grained stainless steel.
- Protection: Corresponds with IP 55, TYPE 12, IK 10.
- Delivery: Enclosure with door, mounting plate, metallic key and mounting accessories.
- Additional information: For outdoor environments exposed to precipitation, the use of a rain hood is advised. Also in environments known for quick temperature changes, consideration to condensation should be taken. Please see the thermal management sectio
Specifications
Application | Hazardous Environments; Factory Automation and Process Control; Corrosive Environments |
Application | Corrosive Environments; Factory Automation and Process Control; Hazardous Environments |
Body Thickness | 1.5 mm |
Body Thickness | 16 ga |
Cable Entry | No |
Color | Unpainted |
Color | Brushed Stainless |
Connection | No |
Construction | Body: 16 gauge Door: 14 gauge |
Cubic Capacity | 35150 Cu-in |
Depth | 15.75 in |
Depth | 400 mm |
Door Thickness | 14 ga |
Door Thickness | 2 mm |
Finish | Brushed |
Height | 1,200 mm |
Height | 47.24 in |
Insulation | No |
IP Rating | IP55 |
Knockouts | No |
Latch Quantity | 1 |
Material | Stainless Steel 316 |
Material | AISI 316L Stainless Steel |
Max Mounting Depth | 382 mm |
Max Mounting Depth | 15.04 in |
Mounting | Wall Mounted |
Mounting Type | Wall-mountable |
Nema Rating | Type 4X |
Number Of Outlet | 1 |
Protection Rating | NEMA Type 12 |
Series | ADR |
Size | 1200x1200x400 mm |
Size | 47.24 x 47.24 x 15.75 inch |
Type | Stainless Steel Wall Mounted Industrial Enclosures |
Weight | 97.3 kg |
Weight | 214.46 lb |
Width | 1,200 mm |
Width | 47.24 in |
Package Dimensions (L x W x H) | 47.62 IN x 47.62 IN x 16.37 IN |
Package Dimensions (L x W x H) | 120.9548 cm x 120.9548 cm x 41.5798 cm |
Package Weight (Imperial) | 214.460 L |
Package Weight (Metric) | 97.279 kg |

BX4
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
LH38
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
LN43DA
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
LT20D-NEW
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, GreyHow to Prepare for ADR1201240-316 Installation
This guide outlines essential safety warnings and general preparatory steps for installing the ADR1201240-316, based on the provided documentation.
Estimated time: 5m
- Review Combustible Surface Requirements
WARNING: Before mounting ADR1201240-316, ensure that if mounting on or over a combustible surface, a floor plate of at least 1.43 mm galvanized or 1.6 mm uncoated steel extended at least 150 mm beyond the equipment on all sides is installed.
- Ensure Enclosure Environmental Integrity
WARNING: To maintain the environmental integrity of the enclosure, use devices with the same environmental ratings to close openings in customized enclosures.
- Prepare Installation Area
Ensure the installation area is clean, dry, and free from obstructions. Verify that all necessary safety precautions are in place before proceeding with any physical installation.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.










