Authorized nVent Distributor
nVent A90XD7824FTCLPG - Sequestr External Disconnect Pkg Gry In Type 12, 90.12x78.50x24.12, Gray, Steel
nVent

A90XD7824FTCLPG

UPC: 783510257910


Documents & Media
Installation Instructions

Contact for Pricing

Overview

Enhance safety and operational efficiency in industrial environments with the nVent Sequestr External Disconnect Package (SKU: A90XD7824FTCLPG). This robust solution is engineered to significantly mitigate arc flash hazards when performing maintenance or accessing internal components of electrical enclosures. By isolating incoming power externally, the Sequestr package allows technicians to safely de-energize the main enclosure without disrupting upstream power distribution, a critical feature for maintaining uptime and ensuring personnel safety. The Sequestr External Disconnect Package is designed for straightforward installation and integration. It arrives as a single, pre-assembled unit, streamlining the setup process for new installations. The package includes a high-quality disconnect switch and a fuse block or circuit breaker, all housed within a durable, gray steel enclosure rated for Type 12 environments. This NEMA Type 12 rating signifies protection against dust, falling dirt, and dripping or light splashing of liquids, making it suitable for a wide range of demanding industrial applications. Key benefits of implementing the nVent Sequestr External Disconnect Package include: * **Arc Flash Hazard Mitigation:** Provides a critical safety barrier by isolating incoming power, drastically reducing the risk of arc flash incidents during internal enclosure work. * **Improved Maintenance Access:** Enables safe and efficient maintenance of internal electrical components by allowing for complete de-energization of the main enclosure. * **Streamlined Installation:** Shipped as a complete, pre-assembled unit for rapid deployment in new installations. * **Durable Construction:** Manufactured from robust steel with a powder-coated gray finish for long-lasting performance in industrial settings. * **NEMA Type 12 Rating:** Offers superior protection against environmental contaminants like dust and dripping liquids, ensuring reliability in challenging conditions. This external disconnect solution is ideal for applications in manufacturing plants, processing facilities, data centers, and any industrial setting where electrical equipment requires regular maintenance. The precise dimensions of 90.12x78.50x24.12 inches provide ample space for the integrated disconnect and protection devices while maintaining a compact footprint. nVent is a globally recognized leader in electrical enclosure solutions, known for its commitment to quality, innovation, and safety. Choosing the Sequestr External Disconnect Package means investing in a reliable, high-performance product from a trusted manufacturer that prioritizes the well-being of your workforce and the integrity of your electrical infrastructure. Ensure compliance with safety regulations and enhance your operational safety protocols with this essential disconnect solution.
  • Interlocks doors of main control cabinet when disconnect switch is powered ON
  • Mechanical interlock on main control enclosure activated by master door prevents slave door from being opened first
  • Provision for pass-through power into the main enclosure
  • Preferred disconnect cutout
  • Quarter-turn, screwdriver slot latch on Sequestr Enclosure
  • Rugged PowerGlide Handle with three-point latch on main control enclosure
  • Concealed, easy-to-remove hinges
  • Grounding studs on body
  • Bonding provision on door
  • Conductive back panel included in Sequestr External Disconnect Enclosure

Specifications

Application
Arc Flash Safety; Power Distribution; Controls and Drives
Color
Gray
Depth
613 mm
Depth
24.12 in
Exterior Color
Gray
Exterior Color Code
ANSI 61
Finish
Powder Coated
Height
2,289 mm
Height
90.12 in
Interior Color
Gray
IP Rating
IP55
Material
Steel
Material
Mild Steel
Modification Services
Yes
NEMA Rating
12 Indoor, dust-resistant
Nema Rating
Type 12
Panel
A90PM78
Panel Size
78.00 x 72.00 in
Panel Size
1981 x 1829 mm
Product Family
Sequestr
Protection Rating
NEMA Type 12
Size
90.12x78.50x24.12 inches
Size
90.12x78.50x24.12 in
Stiffener Locations
24 in
Stiffener Locations
610 mm
Thickness
16 ga
Thickness
1.52 mm
Type
Mild Steel Freestanding Industrial Disconnect Enclosures
Type Number
Type 12
Weight
1,058 lb
Width
1,994 mm
Width
78.5 in
Package Dimensions (L x W x H)
84 IN x 34 IN x 100 IN
Package Dimensions (L x W x H)
213.36 cm x 86.36 cm x 254 cm
Package Weight (Imperial)
1058.000 L
Package Weight (Metric)
479.909 kg
Sequestr External Disconnect Pkg Gry In Type 12, 90.12x78.50x20.12, Gray, Steel

A90XD7820FTCLPG

Sequestr External Disconnect Pkg Gry In Type 12, 90.12x78.50x20.12, Gray, Steel
Sequestr External Disconnect Pkg Gry In Type 12, 90.12x158.00x24.12, Gray, Steel

A90XD4EW24FTCLPG

Sequestr External Disconnect Pkg Gry In Type 12, 90.12x158.00x24.12, Gray, Steel
Sequestr External Disconnect Pkg Gry In Type 12, 84.12x158.00x18.12, Gray, Steel

A84XD4EW18FTCLPG

Sequestr External Disconnect Pkg Gry In Type 12, 84.12x158.00x18.12, Gray, Steel
Sequestr External Disconnect Pkg Gry In Type 12, 72.12x28.25x18.12, Gray, Steel

A72XD2818FTCLPG

Sequestr External Disconnect Pkg Gry In Type 12, 72.12x28.25x18.12, Gray, Steel
Sequestr External Disconnect Pkg Gry In Type 12, 90.12x197.75x18.12, Gray, Steel

A90XD5EW18FTCLPG

Sequestr External Disconnect Pkg Gry In Type 12, 90.12x197.75x18.12, Gray, Steel
Sequestr External Disconnect Pkg Gry In Type 12, 84.12x40.25x18.12, Gray, Steel

A84XD4018FTCLPG

Sequestr External Disconnect Pkg Gry In Type 12, 84.12x40.25x18.12, Gray, Steel
Sequestr External Disconnect Pkg Gry In Type 12, 72.12x34.25x18.12, Gray, Steel

A72XD3418FTCLPG

Sequestr External Disconnect Pkg Gry In Type 12, 72.12x34.25x18.12, Gray, Steel
Sequestr External Disconnect Pkg Gry In Type 12, 84.12x236.00x24.12, Gray, Steel

A84XD6EW24FTCLPG

Sequestr External Disconnect Pkg Gry In Type 12, 84.12x236.00x24.12, Gray, Steel

How to Install the Sequestr External Disconnect Enclosure

This guide provides step-by-step instructions for installing the Sequestr external disconnect enclosure to a control enclosure, ensuring proper mounting, wiring, and initial setup.

Estimated time: 1h

Tools needed:

Screwdriver, Drill, Volt meter, Wire strippers

Supplies needed:

Mounting screws, Terminal connectors, Hoffman hole seal, Hoffman blank adapter plate

  1. Power Down the System

    Turn off the local disconnect in the control enclosure and the feeder disconnect. Wear appropriate Personal Protective Equipment (PPE) and open the control enclosure.

  2. Prepare the Control Enclosure

    Remove the existing disconnect from the control enclosure and seal the existing hole with a Hoffman hole seal. Cover all components in the control enclosure to protect them.

  3. Mount the Sequestr Enclosure

    Remove the subpanel from the Sequestr enclosure. Hang the Sequestr enclosure on the control enclosure using M6x16mm bolts and secure it with washer head cap screws from inside the control enclosure.

  4. Install Circuit Breaker/Disconnect Switch

    Drill mounting holes for the circuit breaker in the panel and install the device according to the manufacturer's instructions. Secure the panel into the Sequestr enclosure with hex nuts.

  5. Wire the Circuit Breaker

    Install conduit and wires to the incoming side of the circuit breaker/disconnect switch in the Sequestr enclosure, ensuring all connections are secure.

  6. Power Up the System

    Remove any protective coverings, ensure the operator handle is in the 'OFF' position, close and latch the Sequestr and control enclosure doors, then turn on the feeder disconnect switch and verify system operation.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.