Authorized nVent Distributor
nVent A84XD6EW24FTCLPG - Sequestr External Disconnect Pkg Gry In Type 12, 84.12x236.00x24.12, Gray, Steel
nVent

A84XD6EW24FTCLPG

UPC: 783510258023


Documents & Media
Installation Instructions

Contact for Pricing

Overview

Enhance safety and streamline maintenance operations with the nVent Sequestr External Disconnect Enclosure Package (SKU: A84XD6EW24FTCLPG). This robust Type 12 enclosure is engineered by nVent, a recognized leader in electrical protection solutions, to significantly mitigate arc flash hazards when performing work on interior electrical components. By providing a secure external point of isolation, the Sequestr package effectively disconnects incoming power from the main enclosure, allowing technicians to safely access and service internal equipment without the risk of unexpected energization. Designed for efficiency and ease of installation, the Sequestr External Disconnect Package is shipped as a single, integrated unit. This pre-assembled configuration includes the disconnect switch and fuse block or circuit breaker, all mounted within the durable, gray steel enclosure. The terminal connections are strategically positioned to facilitate a seamless transition of power to the main electrical enclosure, simplifying the setup process for both new installations and retrofits. The substantial dimensions of 84.12x236.00x24.12 inches ensure ample space for wiring and component accessibility. Key benefits of implementing the nVent Sequestr External Disconnect Package include: * **Arc Flash Hazard Mitigation:** The primary function is to create a safe working environment by isolating live power sources before internal enclosure access. * **Operational Efficiency:** Pre-assembled unit reduces installation time and complexity, minimizing project delays. * **Enhanced Safety Compliance:** Helps facilities meet stringent electrical safety standards and regulations. * **Durable Construction:** Fabricated from high-quality steel with a Type 12 rating, offering protection against dust, falling dirt, and dripping water, suitable for demanding industrial environments. * **Simplified Maintenance:** Enables quicker and safer routine maintenance and troubleshooting of internal electrical systems. This external disconnect solution is invaluable across a wide spectrum of industrial applications, including manufacturing plants, data centers, utility substations, and any facility where regular maintenance of electrical control panels and power distribution systems is required. Professionals in electrical engineering, facility management, and industrial maintenance rely on nVent's commitment to quality and innovation to provide dependable safety solutions. The gray finish of the enclosure adds a professional aesthetic while the robust steel construction ensures longevity and resilience against the rigors of industrial settings. Choosing the nVent Sequestr External Disconnect Package is a proactive step towards safeguarding personnel and ensuring the continuous, safe operation of critical electrical infrastructure.
  • Interlocks doors of main control cabinet when disconnect switch is powered ON
  • Mechanical interlock on main control enclosure activated by master door prevents slave door from being opened first
  • Provision for pass-through power into the main enclosure
  • Preferred disconnect cutout
  • Quarter-turn, screwdriver slot latch on Sequestr Enclosure
  • Rugged PowerGlide Handle with three-point latch on main control enclosure
  • Concealed, easy-to-remove hinges
  • Grounding studs on body
  • Bonding provision on door
  • Conductive back panel included in Sequestr External Disconnect Enclosure

Specifications

Application
Power Distribution; Arc Flash Safety; Controls and Drives
Depth
613 mm
Depth
24.12 in
Exterior Color
Gray
Exterior Color Code
ANSI 61
Finish
Powder Coated
Height
2,137 mm
Height
84.12 in
Interior Color
Gray
IP Rating
IP55
Large Panel
A84PM78
Large Panel Quantity
3
Material
Steel
Material
Mild Steel
Modification Services
Yes
NEMA Rating
12 Indoor, dust-resistant
Panel Size
1829 x 1829 mm
Panel Size
72.00 x 72.00 in
Product Family
Sequestr
Protection Rating
NEMA Type 12
Size
84.12x236.00x24.12 in
Thickness
1.52 mm
Thickness
16 ga
Type
Mild Steel Freestanding Industrial Disconnect Enclosures
Type Number
Type 12
Weight
2,846 lb
Width
5,994 mm
Width
236 in
Package Dimensions (L x W x H)
247 IN x 36 IN x 92 IN
Package Dimensions (L x W x H)
627.38 cm x 91.44 cm x 233.68 cm
Package Weight (Imperial)
2846.000 L
Package Weight (Metric)
1290.946 kg
Sequestr External Disconnect Pkg Gry In Type 12, 84.12x197.75x24.12, Gray, Steel

A84XD5EW24FTCLPG

Sequestr External Disconnect Pkg Gry In Type 12, 84.12x197.75x24.12, Gray, Steel
Sequestr External Disconnect Pkg Gry In Type 12, 90.12x197.75x24.12, Gray, Steel

A90XD5EW24FTCLPG

Sequestr External Disconnect Pkg Gry In Type 12, 90.12x197.75x24.12, Gray, Steel
Sequestr External Disconnect Pkg Gry In Type 12, 90.12x236.00x24.12, Gray, Steel

A90XD6EW24FTCLPG

Sequestr External Disconnect Pkg Gry In Type 12, 90.12x236.00x24.12, Gray, Steel
Sequestr External Disconnect Pkg Gry In Type 12, 84.12x158.00x24.12, Gray, Steel

A84XD4EW24FTCLPG

Sequestr External Disconnect Pkg Gry In Type 12, 84.12x158.00x24.12, Gray, Steel
Sequestr External Disconnect Pkg Gry In Type 12, 84.12x197.75x18.12, Gray, Steel

A84XD5EW18FTCLPG

Sequestr External Disconnect Pkg Gry In Type 12, 84.12x197.75x18.12, Gray, Steel
Sequestr External Disconnect Pkg Gry In Type 12, 72.12x40.25x18.12, Gray, Steel

A72XD4018FTCLPG

Sequestr External Disconnect Pkg Gry In Type 12, 72.12x40.25x18.12, Gray, Steel
Sequestr External Disconnect Pkg Gry In Type 12, 84.12x40.25x24.12, Gray, Steel

A84XD4024FTCLPG

Sequestr External Disconnect Pkg Gry In Type 12, 84.12x40.25x24.12, Gray, Steel
Sequestr External Disconnect Pkg Gry In Type 12, 90.12x40.25x18.12, Gray, Steel

A90XD4018FTCLPG

Sequestr External Disconnect Pkg Gry In Type 12, 90.12x40.25x18.12, Gray, Steel

How to Install the Sequestr External Disconnect Enclosure

This guide provides step-by-step instructions for installing the Sequestr external disconnect enclosure to a control enclosure, ensuring proper mounting, wiring, and initial setup.

Estimated time: 1h

Tools needed:

Screwdriver, Drill, Volt meter, Wire strippers

Supplies needed:

Mounting screws, Terminal connectors, Hoffman hole seal, Hoffman blank adapter plate

  1. Power Down the System

    Turn off the local disconnect in the control enclosure and the feeder disconnect. Wear appropriate Personal Protective Equipment (PPE) and open the control enclosure.

  2. Prepare the Control Enclosure

    Remove the existing disconnect from the control enclosure and seal the existing hole with a Hoffman hole seal. Cover all components in the control enclosure to protect them.

  3. Mount the Sequestr Enclosure

    Remove the subpanel from the Sequestr enclosure. Hang the Sequestr enclosure on the control enclosure using M6x16mm bolts and secure it with washer head cap screws from inside the control enclosure.

  4. Install Circuit Breaker/Disconnect Switch

    Drill mounting holes for the circuit breaker in the panel and install the device according to the manufacturer's instructions. Secure the panel into the Sequestr enclosure with hex nuts.

  5. Wire the Circuit Breaker

    Install conduit and wires to the incoming side of the circuit breaker/disconnect switch in the Sequestr enclosure, ensuring all connections are secure.

  6. Power Up the System

    Remove any protective coverings, ensure the operator handle is in the 'OFF' position, close and latch the Sequestr and control enclosure doors, then turn on the feeder disconnect switch and verify system operation.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.