nVent A907236SSFSDN4 - Freestand 2 Door Single Access 3Pt Type 4X, 90x72x36, Brushed, SS304
nVent

A907236SSFSDN4

UPC: 783510111830


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent A907236SSFSDN4 is a 2-door, freestanding stainless steel enclosure designed for demanding industrial applications. Constructed from 14-gauge brushed SS304 stainless steel, it offers superior corrosion resistance, making it suitable for harsh environments. This enclosure meets NEMA Type 4X, IP66, and IEC 60529 standards, providing protection against dust, dirt, oil, and water ingress. With generous dimensions of 90x72x36 inches, it accommodates large components such as motor starters, VFDs, contactors, and PLCs. The dual-door configuration, coupled with a three-point latching system, ensures a secure seal and convenient access. It is UL 508A listed and cUL certified, making it suitable for machine tools, automotive, pulp and paper, and textile industries. Optional 19-inch rack-mounting accessories are available for protecting sensitive rack-mounted equipment. It also meets NEMA Type 3RX requirements and has been tested for seismic applications with a 1000 lbs. distributed load. This enclosure is part of the nVent HOFFMAN FRESS-STAND SINGLE AND DUAL ACCESS WITH 3-POINT LATCHES, TYPE 4X series.
  • Seams continuously welded and ground smooth; no holes or knockouts
  • Two-door enclosures provided with a removable centerpost for easy panel installation
  • Heavy-duty lifting eyes are Type 316L stainless steel
  • Heavy-duty three-point latching mechanism operated by Type 316L stainless steel PowerGlide padlocking handle
  • Seemless foam-in-place gasket assures a water-tight and dust-tight seal
  • Body flange trough collar excludes liquids and contaminants
  • Heavy-gauge continuous hinges support each door
  • High-impact thermoplastic data pocket provided with each enclosure
  • Mounting channels welded horizontally to interior body sides at top, bottom and center
  • Optional panels and rack mounting angles can be mounted anywhere along channels

Specifications

Application
Controls and Drives;Corrosive Environments;Hygienic Environments
Application
Hygienic Environments; Controls and Drives; Corrosive Environments
Color
Unpainted
Color
Brushed
Depth
916 mm
Depth
36.06
Depth
916
Finish
Brushed #3
Height
2,288 mm
Height
90.06
Height
2,288
Ip Rating
IP66/IP67
IP Rating
IP66
Material
SS304 Stainless Steel
Material
Stainless Steel 304
Material
SS304
Material
Stainless Steel;Stainless Steel 304
Modification Services
Yes
Mounting Type
Freestanding
NEMA Rating
4X Watertight, corrosion-resistant
NEMA Rating
4X
Nema Rating
Type 4X
Protection Rating
NEMA Type 4X
Series
nVent A907236SSFSDN4
Size
90x72x36
Size
90x72x36 inches
Size
90x72x36 in
Size
90.06x72.06x36.06 in
Thickness
2.78 mm
Thickness
12 ga
Thickness
51.40mm (2.024")
Type
Stainless Steel Freestanding Industrial Enclosures
Type Number
Type 3R
Weight
960 lb
Width
1,830 mm
Width
72.06
Width
1,830
Package Dimensions (L x W x H)
81.5 IN x 77.5 IN x 30 IN
Package Dimensions (L x W x H)
207.01 cm x 196.85 cm x 76.2 cm
Package Weight (Imperial)
960.000 L
Package Weight (Metric)
435.456 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the A907236SSFSDN4 Controller

This guide provides step-by-step instructions for installing and configuring the A907236SSFSDN4 controller, including wiring and calibration.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter, Hole saw

Supplies needed:

Mounting screws, Terminal connectors, Watertight conduit hubs

  1. Prepare the installation site

    Select an appropriate location for the controller installation, ensuring it is accessible and complies with local regulations.

  2. Install conduit hubs

    Use a hole saw to cut openings for the watertight conduit hubs according to the size specifications provided. Install the hubs following the manufacturer's instructions.

  3. Mount the controller

    Secure the A907236SSFSDN4 controller to the DIN rail using the provided mounting screws. Ensure it is level and firmly attached.

  4. Connect wiring

    Strip the ends of the wires and connect them to the appropriate terminals on the controller. Use terminal connectors to ensure secure connections.

  5. Verify connections

    Use a multimeter to check all connections for continuity and proper voltage levels before powering on the controller.

  6. Power on the controller

    Turn on the power supply to the controller and observe the startup sequence. Ensure all indicators are functioning as expected.

  7. Calibrate the controller

    Follow the manufacturer's calibration procedure to ensure the controller is accurately configured for your specific application.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.