nVent A902420SSFSN4 - Freestand 1 Door Single Access 3Pt Type 4X, 90x24x20, Brushed, SS304
nVent

A902420SSFSN4

UPC: 783510111465


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent A902420SSFSN4 is a freestanding, single-door stainless steel enclosure designed for harsh industrial environments. Constructed from 14-gauge SS304 stainless steel, this enclosure measures 90 inches high, 24 inches wide, and 20 inches deep, providing ample space for housing electronic controls and sensitive components. It delivers Type 4X and IP66 protection, ensuring resistance to dust, water, and non-corrosive or mildly corrosive elements in both indoor and outdoor applications. The enclosure features a flange trough collar on all four sides of the door opening and a seamless foam-in-place gasket for a tight seal, maintaining environmental integrity. Certified to UL 508A, cUL, NEMA Type 3R, 4, 4X, 12, and IEC 60529 standards, the A902420SSFSN4 is ideal for food processing, pharmaceutical manufacturing, petrochemical plants, and wastewater treatment facilities. Optional 19-inch rack-mounting accessories are available for protecting sensitive rack-mounted components in demanding settings. Weighing 1195 kg with dimensions of 2288 x 611 x 510 mm, this enclosure is built for high-pressure sanitary washdown environments, particularly in food and beverage manufacturing.
  • Seams continuously welded and ground smooth; no holes or knockouts
  • Two-door enclosures provided with a removable centerpost for easy panel installation
  • Heavy-duty lifting eyes are Type 316L stainless steel
  • Heavy-duty three-point latching mechanism operated by Type 316L stainless steel PowerGlide padlocking handle
  • Seemless foam-in-place gasket assures a water-tight and dust-tight seal
  • Body flange trough collar excludes liquids and contaminants
  • Heavy-gauge continuous hinges support each door
  • High-impact thermoplastic data pocket provided with each enclosure
  • Mounting channels welded horizontally to interior body sides at top, bottom and center
  • Optional panels and rack mounting angles can be mounted anywhere along channels

Specifications

Application
Controls and Drives;Corrosive Environments;Hygienic Environments
Application
Corrosive Environments; Hygienic Environments; Controls and Drives
Color
Unpainted
Color
Brushed
Depth
510 mm
Depth
20.06
Depth
510
Finish
Brushed #3
Height
2,288 mm
Height
90.06
Height
2,288
IP Rating
IP66
Ip Rating
IP66/IP67
Material
SS304 Stainless Steel
Material
Stainless Steel;Stainless Steel 304
Material
SS304
Material
Stainless Steel 304
Modification Services
Yes
Mounting Type
Freestand
Mounting Type
Freestanding
NEMA Rating
4X
Nema Rating
Type 4X
NEMA Rating
4X Watertight, corrosion-resistant
Protection Rating
NEMA Type 4X
Series
nVent A902420SSFSN4
Series
ONE-DOOR FS ENCL
Size
90.06x24.06x20.06 in
Size
90x24x20
Size
90x24x20 inches
Thickness
2.78 mm
Thickness
12 ga
Thickness
51.40mm (2.024")
Type
Stainless Steel Freestanding Industrial Enclosures
Type Number
Type 3R
Weight
344 lb
Width
611 mm
Width
24.06
Width
611
Package Dimensions (L x W x H)
36 IN x 36 IN x 100 IN
Package Dimensions (L x W x H)
91.44 cm x 91.44 cm x 254 cm
Package Weight (Imperial)
344.000 L
Package Weight (Metric)
156.038 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the A902420SSFSN4 Controller

This guide provides step-by-step instructions for installing and configuring the A902420SSFSN4 Controller, ensuring proper wiring and initial setup.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors, Power supply

  1. Mount the controller

    Secure the A902420SSFSN4 Controller to the designated mounting surface using the provided mounting screws. Ensure it is level and securely fastened.

  2. Connect the power supply

    Using wire connectors, connect the power supply wires to the corresponding terminals on the controller. Ensure that the connections are tight and insulated to prevent short circuits.

  3. Verify connections

    Use a multimeter to check the voltage at the power terminals of the controller. Confirm that the voltage matches the specifications outlined in the user manual.

  4. Configure initial settings

    Power on the controller and access the configuration menu. Set the required parameters according to your application needs, following the user manual for guidance.

  5. Calibrate the controller

    Follow the calibration procedure as outlined in the user manual to ensure accurate readings and performance. This may involve adjusting settings based on test inputs.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.