Contact for Pricing
Overview
- Overlapping double-door model with 3-point latch and lift-off hinges
- Door stop provision included
- Includes padlock provisions in handle
- Mild steel hinges
- Use with window-type current transformer
- Drip-shield top and seam-free sides, front and back
- Three removable copper buss bars
- Buss bar cross section 3.00 in. x .25 in. (76 mm x 6 mm)
- Neutral bar
- Aluminum mechanical lugs dual rated (Cu/Al), two conductor
Specifications
Application | Controls and Drives; Power Distribution |
Body Thickness | 12 ga |
Body Thickness | 2.66 mm |
Color | Gray |
Color Code | ANSI 61 |
Connection Type | Copper Bus Bars with Aluminum Mechanical Lugs (Dual-rated for Copper/Aluminum) |
Current Rating | 400-800 A |
Depth | 279 mm |
Depth | 11 |
Depth | 279 |
Door Thickness | 1.9 mm |
Door Thickness | 14 ga |
Door Type | Double Door, Hinged |
Finish | Galvanized |
Height | 36 in |
Height | 914 mm |
IP Rating | IP32 |
Material | Mild Steel |
Material | Steel |
Modification Services | Yes |
Mounting Type | Wall Mount |
NEMA Rating | 3R Weather-resistant, except dust |
NEMA Rating | Type 3R |
Protection Rating | NEMA Type 3R |
Series | A800HCT1R |
Size | 35.77x35.8x11.00 in |
Size | 35.77x35.8x11.00 inches (914 x 914 x 305 mm) |
Style | Hinged double-door |
Type | Utility Cabinets |
Type | Utility / Canadian Cabinets and Splitters |
Type Number | Type 3R |
Voltage Rating | 600 VAC |
Weight | 171 lb |
Width | 914 mm |
Width | 36 |
Width | 914 |
Package Dimensions (L x W x H) | 37.38 IN x 13.75 IN x 39.63 IN |
Package Dimensions (L x W x H) | 94.9452 cm x 34.925 cm x 100.6602 cm |
Package Weight (Imperial) | 171.000 L |
Package Weight (Metric) | 77.566 kg |
How to Install the A48R3616NK Controller
This guide provides step-by-step instructions for mounting and wiring the A48R3616NK Controller securely.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors
- Mount the controller
Secure the A48R3616NK controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.
- Connect the wiring
Use terminal connectors to attach the power and signal wires to the appropriate terminals on the controller. Ensure all connections are tight and secure.
- Verify connections
Utilize a multimeter to check the voltage at the terminals to confirm proper power supply. Ensure that all connections are correct before powering on the controller.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.