nVent A72X7324SSLPN4 - Floor-Mount Disconnect 2-Door Right 3pt Latch Type 4X, 72x74x24, Brushed, SS304
nVent

A72X7324SSLPN4

UPC: 783510111076


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent A72X7324SSLPN4 is a Type 4X stainless steel disconnect enclosure designed for industrial environments requiring corrosion-resistant protection. Constructed from brushed 304 stainless steel, this floor-mount enclosure measures 72 inches high, 74 inches wide, and 24 inches deep, providing ample space for housing flange-mounted disconnect switches and circuit breakers from major manufacturers including Allen-Bradley, ABB Controls, Eaton Cutler-Hammer, General Electric, Siemens ITE, and Schneider Square D. Certified to UL 508A and cUL standards, the A72X7324SSLPN4 meets NEMA/EEMAC Type 3R, 4, 4X, and 12 as well as IEC 60529 IP66 requirements. Its 3-point latching mechanism ensures secure door closure and environmental sealing against water and corrosion. Ideal for food and beverage, packaging, water treatment, petroleum, and chemical processing industries, this enclosure provides reliable protection in both indoor and outdoor applications where non-corrosive or mildly corrosive conditions exist.
  • Seams continuously welded and ground smooth
  • Body stiffeners in larger enclosures for extra rigidity
  • Body flange trough collar excludes liquids and contaminants
  • Removable centerposts permit easy panel installation
  • Heavy-gauge continuous hinges
  • Heavy-duty lifting eyes are Type 316 stainless steel
  • Data pocket is high-impact thermoplastic
  • 15-inch floor stands are welded to enclosure
  • Seamless foam-in-place gasket provides oil-tight and dust-tight seal against contaminants
  • Panel supports

Specifications

Application
Arc Flash Safety;Controls and Drives;Corrosive Environments
Application
Controls and Drives; Corrosive Environments; Arc Flash Safety
Color
Unpainted
Color
Brushed
Conductive Panel
A72P72G
Depth
613 mm
Depth
24.12
Depth
613
Finish
Brushed #4
Height
1,832 mm
Height
72.12
Height
1,832
IP Rating
IP66
Ip Rating
IP4X
Material
Stainless Steel 304
Material
SS304
Material
Stainless Steel;Stainless Steel 304
Modification Services
Yes
Mounting Type
Floor-Mount
NEMA Rating
4X Watertight, corrosion-resistant
Nema Rating
Type 4X
NEMA Rating
4X
Panel
A72P72
Panel Size
68.00 x 68.00 in
Panel Size
1727 x 1727 mm
Protection Rating
NEMA Type 12
Series
nVent A72X7324SSLPN4
Size
72.12x73.75x24.12 in
Size
72x74x24
Size
72x74x24 inches
Thickness
12 ga
Thickness
51.40mm (2.024")
Thickness
2.78 mm
Type
Stainless Steel Freestanding Industrial Disconnect Enclosures
Type Number
Type 3R
Weight
762 lb
Width
1,873 mm
Width
73.75
Width
1,873
Package Dimensions (L x W x H)
84 IN x 36 IN x 96.25 IN
Package Dimensions (L x W x H)
213.36 cm x 91.44 cm x 244.475 cm
Package Weight (Imperial)
762.000 L
Package Weight (Metric)
345.643 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the A72X7324SSLPN4 Controller

This guide provides step-by-step instructions for installing and configuring the A72X7324SSLPN4 controller, including wiring and calibration.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors, Watertight conduit hubs

  1. Mount the controller

    Secure the A72X7324SSLPN4 controller to the designated mounting surface using the provided mounting screws. Ensure the controller is level and firmly attached.

  2. Install conduit hubs

    Use a hole saw to cut openings for the watertight conduit hubs as per the recommended sizes in the installation manual. Install the hubs according to the manufacturer's instructions to ensure a secure fit.

  3. Connect wiring

    Strip the ends of the wires and connect them to the appropriate terminals on the controller. Use terminal connectors to secure the connections and ensure they are tight.

  4. Verify connections

    Use a multimeter to check the continuity of the connections. Ensure that all connections are secure and that there are no shorts.

  5. Power on the controller

    Turn on the power supply to the controller and observe the startup sequence. Ensure that the controller powers up without errors.

  6. Calibrate the controller

    Follow the calibration procedure outlined in the user manual to ensure the controller is set up correctly for your application.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.