Authorized nVent Distributor
nVent A726020ULP - Two-Door Floorstand White Inside Type 12, 72.06x60.06x20.06, Gray, Steel

nVent A726020ULP Two-Door Floorstand White Inside Type 12, 72.06x60.06x20.06, Gray, Steel

UPC: 783510277208


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent A726020ULP is a Type 12 steel floorstand enclosure designed for industrial environments, measuring 72.06 inches in height, 60.06 inches in width, and 20.06 inches in depth. Constructed from durable 12-gauge steel, this enclosure provides robust protection against dust, dirt, and dripping water, meeting NEMA/EEMAC Type 12 and IEC 60529 IP55 standards for ingress protection. The enclosure features gasketed, overlapping doors that ensure a secure seal, while the stable floor stand allows for elevated placement, making cleaning and maintenance more efficient. The absence of a centerpost simplifies panel installation and removal, enhancing flexibility for internal component setup. Manufactured in the US, the A726020ULP is suitable for a wide range of industrial applications, including manufacturing, process control, water treatment, and building automation. The interior is finished in gray, providing a neutral backdrop for control systems, PLCs, HMIs, and motor controllers. This enclosure is compatible with the A72P60 panel, constructed from 11-gauge steel, as well as the galvanized A72P60G panel. Additionally, it includes an X-form body stiffener, which enhances structural integrity and durability.
  • Seams continuously welded and ground smooth; no holes or knockouts
  • 3-point latch mechanism operated by oil-tight key-lock handle
  • Gasketed overlapping doors with no centerpost
  • Concealed, easy-to-remove hinges
  • Data pocket is high-impact thermoplastic
  • 12-in. floor stands bolted-on to enclosure
  • Heavy-duty lifting eyes
  • Panel supports
  • Oil-resistant gasket
  • Collar studs for mounting optional panel

Specifications

Application
Controls and Drives;Power Distribution
Color
Gray
Color Code
ANSI 61
Conductive Panel
A72P60G
Depth
13 IN
Depth
20.06 in
Exterior Color
Gray
Exterior Color Code
ANSI 61
Finish
Powder Coated
Height
44 IN
Height
72.06 in
Height
1,830
Interior Color
White
IP Rating
IP55
Material
Steel
Material
Mild Steel
Material
Mild Steel;Steel
Modification Services
Yes
Mounting Type
Floorstand
Nema Rating
Type 12
NEMA Rating
12 Indoor, dust-resistant
Panel
A72P60
Panel Gauge
11
Panel Size
68.00 x 56.00 in
Panel Size
72.00 x 72.00 in
Protection Rating
NEMA Type 12
Size
72.06x60.06x20.06 in
Size
72.06x60.06x20.06
Stiffener
21 in
Stiffener
381 mm
Thickness
51.40mm (2.024")
Thickness
12 ga
Type
Mild Steel Freestanding Industrial Enclosures
Type Number
Type 12
Weight
573 lb
Width
23 IN
Width
60.06 in
Width
1,526
Package Dimensions (L x W x H)
68 IN x 36 IN x 94 IN
Package Dimensions (L x W x H)
172.72 cm x 91.44 cm x 238.76 cm
Package Weight (Imperial)
573.000 L
Package Weight (Metric)
259.913 kg
Two-Door Floorstand White Inside Type 12, 72.06x60.06x16.06, Gray, Steel

A726016ULP

Two-Door Floorstand White Inside Type 12, 72.06x60.06x16.06, Gray, Steel
Access Floor Module Cover, Galvanized Steel, GFCI Cover Sloped 45 Degrees, Power Panel

AFP-6-GFCI-45

Access Floor Module Cover, Galvanized Steel, GFCI Cover Sloped 45 Degrees, Power Panel
Two-Door Floorstand White Inside Type 12, 72.06x72.06x24.06, Gray, Steel

A727224ULP

Two-Door Floorstand White Inside Type 12, 72.06x72.06x24.06, Gray, Steel
Two-Door Floorstand White Inside Type 12, 72.06x60.06x10.06, Gray, Steel

A726010ULP

Two-Door Floorstand White Inside Type 12, 72.06x60.06x10.06, Gray, Steel
Two-Door Floorstand White Inside Type 12, 72.06x60.06x24.06, Gray, Steel

A726024ULP

Two-Door Floorstand White Inside Type 12, 72.06x60.06x24.06, Gray, Steel
Two-Door Floorstand White Inside Type 12, 72.06x72.06x20.06, Gray, Steel

A727220ULP

Two-Door Floorstand White Inside Type 12, 72.06x72.06x20.06, Gray, Steel
Two-Door Floorstand White Inside Type 12, 72.06x72.06x10.06, Gray, Steel

A727210ULP

Two-Door Floorstand White Inside Type 12, 72.06x72.06x10.06, Gray, Steel
Two-Door Floorstand White Inside Type 12, 72.06x60.06x12.06, Gray, Steel

A726012ULP

Two-Door Floorstand White Inside Type 12, 72.06x60.06x12.06, Gray, Steel

How to Repaint a Hoffman Enclosure

Guide on preparing and repainting Hoffman enclosures with TGIC polyester powder coating.

Estimated time: 1h

Tools needed:

180 grit sandpaper, 220 or 240 grit sandpaper (optional), Solvent, Paint manufacturer's recommended tools

Supplies needed:

TGIC polyester powder coated Hoffman enclosure, Paint compatible with TGIC polyester powder coating, Primer (if recommended by paint manufacturer)

  1. Prepare the Surface

    Thoroughly sand all enclosure surfaces with 180 grit sandpaper. If sanding marks are objectionable, finish sanding with 220 or 240 grit sandpaper. Wet wipe all surfaces with a solvent to remove any possible contaminants. Consult with your paint manufacturer for proper cure time and hardness prior to testing the paint for adhesion.

  2. Select Appropriate Paint

    Choose a paint that exhibits good adhesion properties over polyester powder. Recommended types include two-component epoxies, some two-component polyurethanes, and alkyd baking enamels. If using alkyd finishes, do not bake at temperatures exceeding 150°F to avoid discoloration.

  3. Apply Paint

    Apply two or three medium to light coats of paint. Allow two to three minutes flash off between coats. Allow paint to cure adequately according to the paint manufacturer's instructions.

  4. Test Adhesion

    After the paint has cured adequately, test the paint for adhesion. Consult with your paint manufacturer for proper cure time and hardness prior to testing.

  5. Test Repainting Process

    NOTICE: Always test the repainting process on an inconspicuous area prior to full application.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.