Authorized nVent Distributor
nVent A726016ULP - Two-Door Floorstand White Inside Type 12, 72.06x60.06x16.06, Gray, Steel

nVent A726016ULP Two-Door Floorstand White Inside Type 12, 72.06x60.06x16.06, Gray, Steel

UPC: 783510277000


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent A726016ULP is a Type 12 two-door floorstand enclosure designed for industrial environments requiring protection against dust, dirt, and water ingress. This enclosure measures 72.06 inches in height, 60.06 inches in width, and 16.06 inches in depth, providing substantial interior space for complex control systems, power distribution units, and instrumentation. Constructed from durable steel with a gray exterior finish, it meets UL 508A, cUL, NEMA/EEMAC Type 12, and IEC 60529 (IP55) standards for reliable performance in harsh conditions. Key features include gasketed, overlapping doors for superior sealing, a white interior for enhanced visibility, and a floorstand design that elevates the unit for under-unit cleaning access. The absence of a centerpost simplifies panel installation and removal, reducing labor time. Ideal for manufacturing, water treatment, and food processing industries, this enclosure ensures operational continuity by safeguarding sensitive equipment from environmental contaminants.
  • Seams continuously welded and ground smooth; no holes or knockouts
  • 3-point latch mechanism operated by oil-tight key-lock handle
  • Gasketed overlapping doors with no centerpost
  • Concealed, easy-to-remove hinges
  • Data pocket is high-impact thermoplastic
  • 12-in. floor stands bolted-on to enclosure
  • Heavy-duty lifting eyes
  • Panel supports
  • Oil-resistant gasket
  • Collar studs for mounting optional panel

Specifications

Application
Controls and Drives;Power Distribution
Color
Gray (exterior), White (interior)
Color
Gray
Color Code
ANSI 61
Conductive Panel
A72P60G
Depth
13 IN
Depth
16.06 in
Exterior Color
Gray
Exterior Color Code
ANSI 61
Finish
Powder Coated
Height
1,830
Height
72.06 in
Height
44 IN
Interior Color
White
IP Rating
IP55
Material
Steel
Material
Mild Steel
Material
Mild Steel;Steel
Modification Services
Yes
Mounting Type
Floorstand
Nema Rating
Type 12
NEMA Rating
12 Indoor, dust-resistant
Panel
A72P60
Panel Gauge
11
Panel Size
72.00 x 72.00 in
Panel Size
68.00 x 56.00 in
Protection Rating
NEMA Type 12
Size
72.06x60.06x16.06 in
Stiffener
21 in
Stiffener
381 mm
Thickness
51.40mm (2.024")
Thickness
12 ga
Type
Mild Steel Freestanding Industrial Enclosures
Type Number
Type 12
Weight
529 lb
Width
60.06 in
Width
1,526
Width
23 IN
Package Dimensions (L x W x H)
68 IN x 30 IN x 94 IN
Package Dimensions (L x W x H)
172.72 cm x 76.2 cm x 238.76 cm
Package Weight (Imperial)
529.000 L
Package Weight (Metric)
239.954 kg
Two-Door Floorstand White Inside Type 12, 60.06x60.06x16.06, Gray, Steel

A606016LP

Two-Door Floorstand White Inside Type 12, 60.06x60.06x16.06, Gray, Steel
Access Floor Module Cover, Galvanized Steel, GFCI Cover Sloped 45 Degrees, Power Panel

AFP-6-GFCI-45

Access Floor Module Cover, Galvanized Steel, GFCI Cover Sloped 45 Degrees, Power Panel
Two-Door Floorstand White Inside Type 12, 72.06x72.06x12.06, Gray, Steel

A727212ULP

Two-Door Floorstand White Inside Type 12, 72.06x72.06x12.06, Gray, Steel
Two-Door Floorstand White Inside Type 12, 72.06x60.06x20.06, Gray, Steel

A726020ULP

Two-Door Floorstand White Inside Type 12, 72.06x60.06x20.06, Gray, Steel
Two-Door Floorstand White Inside Type 12, 72.06x72.06x24.06, Gray, Steel

A727224ULP

Two-Door Floorstand White Inside Type 12, 72.06x72.06x24.06, Gray, Steel
Two-Door Floorstand White Inside Type 12, 72.06x60.06x10.06, Gray, Steel

A726010ULP

Two-Door Floorstand White Inside Type 12, 72.06x60.06x10.06, Gray, Steel
Two-Door Floorstand White Inside Type 12, 72.06x60.06x24.06, Gray, Steel

A726024ULP

Two-Door Floorstand White Inside Type 12, 72.06x60.06x24.06, Gray, Steel
Two-Door Floorstand White Inside Type 12, 72.06x72.06x20.06, Gray, Steel

A727220ULP

Two-Door Floorstand White Inside Type 12, 72.06x72.06x20.06, Gray, Steel

How to Repaint a Hoffman Enclosure

Guide on preparing and repainting Hoffman enclosures with TGIC polyester powder coating.

Estimated time: 1h

Tools needed:

180 grit sandpaper, 220 or 240 grit sandpaper (optional), Solvent, Paint manufacturer's recommended tools

Supplies needed:

TGIC polyester powder coated Hoffman enclosure, Paint compatible with TGIC polyester powder coating, Primer (if recommended by paint manufacturer)

  1. Prepare the Surface

    Thoroughly sand all enclosure surfaces with 180 grit sandpaper. If sanding marks are objectionable, finish sanding with 220 or 240 grit sandpaper. Wet wipe all surfaces with a solvent to remove any possible contaminants. Consult with your paint manufacturer for proper cure time and hardness prior to testing the paint for adhesion.

  2. Select Appropriate Paint

    Choose a paint that exhibits good adhesion properties over polyester powder. Recommended types include two-component epoxies, some two-component polyurethanes, and alkyd baking enamels. If using alkyd finishes, do not bake at temperatures exceeding 150°F to avoid discoloration.

  3. Apply Paint

    Apply two or three medium to light coats of paint. Allow two to three minutes flash off between coats. Allow paint to cure adequately according to the paint manufacturer's instructions.

  4. Test Adhesion

    After the paint has cured adequately, test the paint for adhesion. Consult with your paint manufacturer for proper cure time and hardness prior to testing.

  5. Test Repainting Process

    NOTICE: Always test the repainting process on an inconspicuous area prior to full application.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.