nVent A726018SSFSDN4 - Freestand 2 Door Single Access 3Pt Type 4X, 72x60x18, Brushed, SS304
nVent

A726018SSFSDN4

UPC: 783510111724


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent A726018SSFSDN4 is a robust, freestanding Type 4X enclosure constructed from SS304 brushed stainless steel. Measuring 72 inches high, 60 inches wide, and 18 inches deep, this enclosure offers substantial internal space for electrical and electronic equipment. Its two-door design ensures convenient single access for maintenance and component installation. Engineered for demanding industrial environments, it provides superior protection against dust, dirt, oil, and water ingress, meeting IEC 60529 IP66 standards and NEMA Type 4X ratings. This enclosure is UL 508A Listed and cUL Listed per CSA C22.2 No 94, with Type 3R, 4, 4X, and 12 ratings. It also complies with NEMA/EEMAC Type 3, 3R, 4, 4X, 12, 13 standards. The robust SS304 construction ensures excellent corrosion resistance, making it ideal for applications in food processing, pharmaceutical manufacturing, petrochemical plants, and wastewater treatment facilities. Manufactured in the USA, the A726018SSFSDN4 is built for reliability and longevity in harsh conditions.
  • Seams continuously welded and ground smooth; no holes or knockouts
  • Two-door enclosures provided with a removable centerpost for easy panel installation
  • Heavy-duty lifting eyes are Type 316L stainless steel
  • Heavy-duty three-point latching mechanism operated by Type 316L stainless steel PowerGlide padlocking handle
  • Seemless foam-in-place gasket assures a water-tight and dust-tight seal
  • Body flange trough collar excludes liquids and contaminants
  • Heavy-gauge continuous hinges support each door
  • High-impact thermoplastic data pocket provided with each enclosure
  • Mounting channels welded horizontally to interior body sides at top, bottom and center
  • Optional panels and rack mounting angles can be mounted anywhere along channels

Specifications

Application
Controls and Drives;Corrosive Environments;Hygienic Environments
Application
Corrosive Environments; Hygienic Environments; Controls and Drives
Color
Brushed
Color
Unpainted
Depth
459 mm
Depth
18.06
Depth
459
Finish
Brushed #3
Height
1,830 mm
Height
72.06
Height
1,830
IP Rating
IP66
Ip Rating
IP66/IP67
Material
SS304 Stainless Steel
Material
Stainless Steel 304
Material
Stainless Steel;Stainless Steel 304
Modification Services
Yes
Mounting Type
Freestanding
NEMA Rating
4X Watertight, corrosion-resistant
NEMA Rating
4X
Nema Rating
Type 4X
Protection Rating
NEMA Type 4X
Series
nVent A726018SSFSDN4
Size
72.06x60.06x18.06 in
Size
72x60x18 inches
Thickness
12 ga
Thickness
51.40mm (2.024")
Thickness
2.78 mm
Type
Stainless Steel Freestanding Industrial Enclosures
Type Number
Type 3R
Weight
531 lb
Width
1,526 mm
Width
60.06
Width
1,526
Package Dimensions (L x W x H)
68 IN x 38 IN x 81.75 IN
Package Dimensions (L x W x H)
172.72 cm x 96.52 cm x 207.645 cm
Package Weight (Imperial)
531.000 L
Package Weight (Metric)
240.862 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the A726018SSFSDN4 Controller

This guide provides step-by-step instructions for installing and configuring the A726018SSFSDN4 Controller on a DIN rail.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors

  1. Mount the controller

    Secure the A726018SSFSDN4 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the power supply

    Using wire connectors, connect the power supply wires to the designated terminals on the controller. Verify that the connections are secure and insulated.

  3. Configure the controller settings

    Power on the controller and use the configuration software to set the desired parameters. Follow the on-screen prompts to complete the setup.

  4. Calibrate the controller

    Perform a calibration of the controller by following the calibration procedure in the software. Ensure all readings are within the specified range.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.