The nVent A724818SSFSDN4 is a 2-door freestanding NEMA Type 4X stainless steel enclosure measuring 72" x 48" x 18" (1829 x 1219 x 457 mm). Constructed from 304 stainless steel with a brushed finish, it provides superior corrosion resistance for harsh industrial environments. This enclosure meets NEMA Type 4X, Type 12, IP66, and UL 508A standards, offering protection against dust, water, oil, and non-corrosive chemicals. The three-point latching system ensures a secure seal, while the freestanding design simplifies installation in facilities with limited wall space. Compatible with 19-inch rack-mounting accessories, it supports complex mounting configurations for large components such as PLCs, VFDs, motor starters, and control panels. Typical applications include food processing, pharmaceutical manufacturing, petrochemical plants, pulp and paper processing, and wastewater treatment facilities. The enclosure features continuous welds, ground smooth seams, and a flange trough collar for enhanced durability and protection. Pre-drilled mounting holes facilitate easy installation, and optional accessories are available for cable management, ventilation, or heat dissipation.
  • Seams continuously welded and ground smooth; no holes or knockouts
  • Two-door enclosures provided with a removable centerpost for easy panel installation
  • Heavy-duty lifting eyes are Type 316L stainless steel
  • Heavy-duty three-point latching mechanism operated by Type 316L stainless steel PowerGlide padlocking handle
  • Seemless foam-in-place gasket assures a water-tight and dust-tight seal
  • Body flange trough collar excludes liquids and contaminants
  • Heavy-gauge continuous hinges support each door
  • High-impact thermoplastic data pocket provided with each enclosure
  • Mounting channels welded horizontally to interior body sides at top, bottom and center
  • Optional panels and rack mounting angles can be mounted anywhere along channels

Specifications

Application
Controls and Drives;Corrosive Environments;Hygienic Environments
Application
Hygienic Environments; Corrosive Environments; Controls and Drives
Color
Unpainted
Color
Brushed
Depth
459 mm
Depth
18.06
Depth
459
Finish
Brushed #3
Height
1,830 mm
Height
72.06
Height
1,830
IP Rating
IP66
Ip Rating
IP4X
Material
SS304
Material
304 Stainless Steel
Material
Stainless Steel;Stainless Steel 304
Material
Stainless Steel 304
Modification Services
Yes
Mounting Type
Freestanding
NEMA Rating
4X Watertight, corrosion-resistant
NEMA Rating
4X
Nema Rating
Type 4X
Protection Rating
NEMA Type 4X
Series
nVent Freestand
Size
72" x 48" x 18" (1829 x 1219 x 457 mm)
Size
72x48x18 inches
Size
72.06x48.06x18.06 in
Thickness
12 ga
Thickness
2.78 mm
Thickness
51.40mm (2.024")
Type
Stainless Steel Freestanding Industrial Enclosures
Type Number
Type 3R
Weight
462 lb
Width
1,221 mm
Width
48.06
Width
1,221
Package Dimensions (L x W x H)
56 IN x 34 IN x 82 IN
Package Dimensions (L x W x H)
142.24 cm x 86.36 cm x 208.28 cm
Package Weight (Imperial)
462.000 L
Package Weight (Metric)
209.563 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the A724818SSFSDN4 Enclosure

This guide provides step-by-step instructions for mounting and wiring the A724818SSFSDN4 enclosure securely.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors, Metal shims

  1. Mount the enclosure

    Secure the enclosure to the wall or floor using proper fasteners in all mounting holes. Ensure the enclosure is level and firmly attached.

  2. Adjust the door closing

    If the enclosure is not level, use metal shims under the corners to ensure the doors close evenly. Tighten all mounting screws securely.

  3. Install the interior panel

    Position the interior panel on the mounting studs and adjust any studs as necessary to fit the panel in place. Ensure all connections are secure.

  4. Connect wiring

    Use terminal connectors to connect the wiring to the appropriate terminals inside the enclosure. Verify connections with a multimeter.

  5. Calibrate the enclosure

    Once all components are installed and wired, power on the enclosure and check for proper operation. Adjust settings as necessary.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.